Experimental studies on viscofluids for intraocular surgery

Identifieur interne : 008F56 ( Main/Merge ); précédent : 008F55; suivant : 008F57

Experimental studies on viscofluids for intraocular surgery

Auteurs : Ehud I. Assia [Israël] ; Meir Yehezkel ; Nathan Ezov ; Giora Treister [Israël] ; Michael Blumenthal [Israël]

Source :

RBID : ISTEX:7F9073FB9E28EF28B38E74613117D2E9319BDB0D

Abstract

Purpose: To investigate the feasibility and efficacy of using diluted viscofluids during intraocular surgery.Setting: Laboratory for Intraocular Microsurgery and Implants, Goldschleger -Eye Research Institute, and the Sackler School of Medicine, Tel-Hashomer, Israel.Methods: Diluted hyaluronic acid (0.06 to 0.12%) in balanced salt solutions were irrigated through the phacoemulsification machine or a separate irrigation line (i.e., anterior chamber maintainer). Irrigation was facilitated by increasing the atmospheric pressure in the bottle using compressed air. Experimental surgery was done in rabbit eyes.Results: A viscous fluid could be irrigated at any practical rate by increasing the height of the bottle, increasing the atmospheric pressure within the bottle, or both. Experimental surgeries showed that viscofluids maintained intraocular pressure and anterior chamber volume, allowed safe intraocular manipulations, reduced turbulence in the anterior chamber, and probably provided tissue protection.Conclusion: Viscofluids irrigated using a high-pressure system combined the advantages of continuous irrigation of fluids and the protective qualities of viscoelastics in this rabbit eye study.

Url:
DOI: 10.1016/S0886-3350(98)80078-3

Links toward previous steps (curation, corpus...)


Links to Exploration step

ISTEX:7F9073FB9E28EF28B38E74613117D2E9319BDB0D

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Experimental studies on viscofluids for intraocular surgery</title>
<author>
<name sortKey="Assia, Ehud I" sort="Assia, Ehud I" uniqKey="Assia E" first="Ehud I." last="Assia">Ehud I. Assia</name>
</author>
<author>
<name sortKey="Yehezkel, Meir" sort="Yehezkel, Meir" uniqKey="Yehezkel M" first="Meir" last="Yehezkel">Meir Yehezkel</name>
</author>
<author>
<name sortKey="Ezov, Nathan" sort="Ezov, Nathan" uniqKey="Ezov N" first="Nathan" last="Ezov">Nathan Ezov</name>
</author>
<author>
<name sortKey="Treister, Giora" sort="Treister, Giora" uniqKey="Treister G" first="Giora" last="Treister">Giora Treister</name>
</author>
<author>
<name sortKey="Blumenthal, Michael" sort="Blumenthal, Michael" uniqKey="Blumenthal M" first="Michael" last="Blumenthal">Michael Blumenthal</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:7F9073FB9E28EF28B38E74613117D2E9319BDB0D</idno>
<date when="1998" year="1998">1998</date>
<idno type="doi">10.1016/S0886-3350(98)80078-3</idno>
<idno type="url">https://api.istex.fr/document/7F9073FB9E28EF28B38E74613117D2E9319BDB0D/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">002402</idno>
<idno type="wicri:Area/Istex/Curation">002402</idno>
<idno type="wicri:Area/Istex/Checkpoint">003939</idno>
<idno type="wicri:doubleKey">0886-3350:1998:Assia E:experimental:studies:on</idno>
<idno type="wicri:Area/Main/Merge">008F56</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Experimental studies on viscofluids for intraocular surgery</title>
<author>
<name sortKey="Assia, Ehud I" sort="Assia, Ehud I" uniqKey="Assia E" first="Ehud I." last="Assia">Ehud I. Assia</name>
<affiliation>
<wicri:noCountry code="subField">aba</wicri:noCountry>
</affiliation>
<affiliation wicri:level="1">
<country xml:lang="fr">Israël</country>
<wicri:regionArea>Reprint requests to Ehud I. Assia, MD, Director, Department of Ophthalmology, Meir Hospital, Sapir Medical Center, Kfar-Saba 44281</wicri:regionArea>
<wicri:noRegion>Kfar-Saba 44281</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Yehezkel, Meir" sort="Yehezkel, Meir" uniqKey="Yehezkel M" first="Meir" last="Yehezkel">Meir Yehezkel</name>
<affiliation>
<wicri:noCountry code="subField">aba</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Ezov, Nathan" sort="Ezov, Nathan" uniqKey="Ezov N" first="Nathan" last="Ezov">Nathan Ezov</name>
<affiliation>
<wicri:noCountry code="subField">Rehovot</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Treister, Giora" sort="Treister, Giora" uniqKey="Treister G" first="Giora" last="Treister">Giora Treister</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Israël</country>
<wicri:regionArea>From the Department of Ophthalmology, Goldschleger Eye Institute, Sheba Medical Center, Tel-Hashomer (Treister, Blumenthal)</wicri:regionArea>
<wicri:noRegion>Blumenthal)</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Blumenthal, Michael" sort="Blumenthal, Michael" uniqKey="Blumenthal M" first="Michael" last="Blumenthal">Michael Blumenthal</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Israël</country>
<wicri:regionArea>From the Department of Ophthalmology, Goldschleger Eye Institute, Sheba Medical Center, Tel-Hashomer (Treister, Blumenthal)</wicri:regionArea>
<wicri:noRegion>Blumenthal)</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Journal of Cataract & Refractive Surgery</title>
<title level="j" type="abbrev">JCRS</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1998">1998</date>
<biblScope unit="volume">24</biblScope>
<biblScope unit="issue">1</biblScope>
<biblScope unit="page" from="78">78</biblScope>
<biblScope unit="page" to="83">83</biblScope>
</imprint>
<idno type="ISSN">0886-3350</idno>
</series>
<idno type="istex">7F9073FB9E28EF28B38E74613117D2E9319BDB0D</idno>
<idno type="DOI">10.1016/S0886-3350(98)80078-3</idno>
<idno type="PII">S0886-3350(98)80078-3</idno>
<idno type="ArticleID">80078</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Purpose: To investigate the feasibility and efficacy of using diluted viscofluids during intraocular surgery.Setting: Laboratory for Intraocular Microsurgery and Implants, Goldschleger -Eye Research Institute, and the Sackler School of Medicine, Tel-Hashomer, Israel.Methods: Diluted hyaluronic acid (0.06 to 0.12%) in balanced salt solutions were irrigated through the phacoemulsification machine or a separate irrigation line (i.e., anterior chamber maintainer). Irrigation was facilitated by increasing the atmospheric pressure in the bottle using compressed air. Experimental surgery was done in rabbit eyes.Results: A viscous fluid could be irrigated at any practical rate by increasing the height of the bottle, increasing the atmospheric pressure within the bottle, or both. Experimental surgeries showed that viscofluids maintained intraocular pressure and anterior chamber volume, allowed safe intraocular manipulations, reduced turbulence in the anterior chamber, and probably provided tissue protection.Conclusion: Viscofluids irrigated using a high-pressure system combined the advantages of continuous irrigation of fluids and the protective qualities of viscoelastics in this rabbit eye study.</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 008F56 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 008F56 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Merge
   |type=    RBID
   |clé=     ISTEX:7F9073FB9E28EF28B38E74613117D2E9319BDB0D
   |texte=   Experimental studies on viscofluids for intraocular surgery
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024