The SWORD tele-rehabilitation system.
Identifieur interne : 000273 ( PubMed/Curation ); précédent : 000272; suivant : 000274The SWORD tele-rehabilitation system.
Auteurs : Virgílio F. Bento [Portugal] ; Vítor T. Cruz ; David D. Ribeiro ; Márcio M. Colunas ; João P S. CunhaSource :
- Studies in health technology and informatics [ 0926-9630 ] ; 2012.
Descripteurs français
- KwdFr :
- MESH :
- diagnostic : Troubles de la motricité.
- rééducation et réadaptation : Troubles de la motricité.
- Bras, Humains, Interface utilisateur, Rétroaction biologique (psychologie), Thérapie assistée par ordinateur, Télémédecine.
English descriptors
- KwdEn :
- MESH :
- diagnosis : Movement Disorders.
- methods : Biofeedback, Psychology, Telemedicine, Therapy, Computer-Assisted.
- rehabilitation : Movement Disorders.
- Arm, Humans, User-Computer Interface.
Abstract
In spite of the growing interest verified in the field of technology-based interventions for Stroke rehabilitation, there is still no global solution that is both successful and suitable for a widespread use [1,2]. In this article, we present a novel tele-rehabilitation tool designed to be used for ambulatory patients, and developed towards the motor recovery of the patient's upper-limb. The SWORD system combines a movement quantification system that analyzes the quality of the motor task performed with a biofeedback console. The proposed structure defines the SWORD system as a complete tele-rehabilitation framework that enables a direct connection between clinical and ambulatory settings. Currently a randomized clinical trial is being designed in order to assess the effectiveness of the SWORD tele-rehabilitation system.
PubMed: 22942034
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: Pour aller vers cette notice dans l'étape Curation :000273
Links to Exploration step
pubmed:22942034Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">The SWORD tele-rehabilitation system.</title>
<author><name sortKey="Bento, Virgilio F" sort="Bento, Virgilio F" uniqKey="Bento V" first="Virgílio F" last="Bento">Virgílio F. Bento</name>
<affiliation wicri:level="1"><nlm:affiliation>Institute of Electronics and Telematics Engineering of Aveiro, University of Aveiro, Aveiro, Portugal. vbento@ua.pt</nlm:affiliation>
<country xml:lang="fr">Portugal</country>
<wicri:regionArea>Institute of Electronics and Telematics Engineering of Aveiro, University of Aveiro, Aveiro</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Cruz, Vitor T" sort="Cruz, Vitor T" uniqKey="Cruz V" first="Vítor T" last="Cruz">Vítor T. Cruz</name>
</author>
<author><name sortKey="Ribeiro, David D" sort="Ribeiro, David D" uniqKey="Ribeiro D" first="David D" last="Ribeiro">David D. Ribeiro</name>
</author>
<author><name sortKey="Colunas, Marcio M" sort="Colunas, Marcio M" uniqKey="Colunas M" first="Márcio M" last="Colunas">Márcio M. Colunas</name>
</author>
<author><name sortKey="Cunha, Joao P S" sort="Cunha, Joao P S" uniqKey="Cunha J" first="João P S" last="Cunha">João P S. Cunha</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="RBID">pubmed:22942034</idno>
<idno type="pmid">22942034</idno>
<idno type="wicri:Area/PubMed/Corpus">000273</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000273</idno>
<idno type="wicri:Area/PubMed/Curation">000273</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000273</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">The SWORD tele-rehabilitation system.</title>
<author><name sortKey="Bento, Virgilio F" sort="Bento, Virgilio F" uniqKey="Bento V" first="Virgílio F" last="Bento">Virgílio F. Bento</name>
<affiliation wicri:level="1"><nlm:affiliation>Institute of Electronics and Telematics Engineering of Aveiro, University of Aveiro, Aveiro, Portugal. vbento@ua.pt</nlm:affiliation>
<country xml:lang="fr">Portugal</country>
<wicri:regionArea>Institute of Electronics and Telematics Engineering of Aveiro, University of Aveiro, Aveiro</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Cruz, Vitor T" sort="Cruz, Vitor T" uniqKey="Cruz V" first="Vítor T" last="Cruz">Vítor T. Cruz</name>
</author>
<author><name sortKey="Ribeiro, David D" sort="Ribeiro, David D" uniqKey="Ribeiro D" first="David D" last="Ribeiro">David D. Ribeiro</name>
</author>
<author><name sortKey="Colunas, Marcio M" sort="Colunas, Marcio M" uniqKey="Colunas M" first="Márcio M" last="Colunas">Márcio M. Colunas</name>
</author>
<author><name sortKey="Cunha, Joao P S" sort="Cunha, Joao P S" uniqKey="Cunha J" first="João P S" last="Cunha">João P S. Cunha</name>
</author>
</analytic>
<series><title level="j">Studies in health technology and informatics</title>
<idno type="ISSN">0926-9630</idno>
<imprint><date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Arm</term>
<term>Biofeedback, Psychology (methods)</term>
<term>Humans</term>
<term>Movement Disorders (diagnosis)</term>
<term>Movement Disorders (rehabilitation)</term>
<term>Telemedicine (methods)</term>
<term>Therapy, Computer-Assisted (methods)</term>
<term>User-Computer Interface</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr"><term>Bras</term>
<term>Humains</term>
<term>Interface utilisateur</term>
<term>Rétroaction biologique (psychologie) ()</term>
<term>Thérapie assistée par ordinateur ()</term>
<term>Troubles de la motricité (diagnostic)</term>
<term>Troubles de la motricité (rééducation et réadaptation)</term>
<term>Télémédecine ()</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnosis" xml:lang="en"><term>Movement Disorders</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic" xml:lang="fr"><term>Troubles de la motricité</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Biofeedback, Psychology</term>
<term>Telemedicine</term>
<term>Therapy, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en"><term>Movement Disorders</term>
</keywords>
<keywords scheme="MESH" qualifier="rééducation et réadaptation" xml:lang="fr"><term>Troubles de la motricité</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Arm</term>
<term>Humans</term>
<term>User-Computer Interface</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr"><term>Bras</term>
<term>Humains</term>
<term>Interface utilisateur</term>
<term>Rétroaction biologique (psychologie)</term>
<term>Thérapie assistée par ordinateur</term>
<term>Télémédecine</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">In spite of the growing interest verified in the field of technology-based interventions for Stroke rehabilitation, there is still no global solution that is both successful and suitable for a widespread use [1,2]. In this article, we present a novel tele-rehabilitation tool designed to be used for ambulatory patients, and developed towards the motor recovery of the patient's upper-limb. The SWORD system combines a movement quantification system that analyzes the quality of the motor task performed with a biofeedback console. The proposed structure defines the SWORD system as a complete tele-rehabilitation framework that enables a direct connection between clinical and ambulatory settings. Currently a randomized clinical trial is being designed in order to assess the effectiveness of the SWORD tele-rehabilitation system.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">22942034</PMID>
<DateCreated><Year>2012</Year>
<Month>09</Month>
<Day>03</Day>
</DateCreated>
<DateCompleted><Year>2012</Year>
<Month>09</Month>
<Day>27</Day>
</DateCompleted>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0926-9630</ISSN>
<JournalIssue CitedMedium="Print"><Volume>177</Volume>
<PubDate><Year>2012</Year>
</PubDate>
</JournalIssue>
<Title>Studies in health technology and informatics</Title>
<ISOAbbreviation>Stud Health Technol Inform</ISOAbbreviation>
</Journal>
<ArticleTitle>The SWORD tele-rehabilitation system.</ArticleTitle>
<Pagination><MedlinePgn>76-81</MedlinePgn>
</Pagination>
<Abstract><AbstractText>In spite of the growing interest verified in the field of technology-based interventions for Stroke rehabilitation, there is still no global solution that is both successful and suitable for a widespread use [1,2]. In this article, we present a novel tele-rehabilitation tool designed to be used for ambulatory patients, and developed towards the motor recovery of the patient's upper-limb. The SWORD system combines a movement quantification system that analyzes the quality of the motor task performed with a biofeedback console. The proposed structure defines the SWORD system as a complete tele-rehabilitation framework that enables a direct connection between clinical and ambulatory settings. Currently a randomized clinical trial is being designed in order to assess the effectiveness of the SWORD tele-rehabilitation system.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Bento</LastName>
<ForeName>Virgílio F</ForeName>
<Initials>VF</Initials>
<AffiliationInfo><Affiliation>Institute of Electronics and Telematics Engineering of Aveiro, University of Aveiro, Aveiro, Portugal. vbento@ua.pt</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Cruz</LastName>
<ForeName>Vítor T</ForeName>
<Initials>VT</Initials>
</Author>
<Author ValidYN="Y"><LastName>Ribeiro</LastName>
<ForeName>David D</ForeName>
<Initials>DD</Initials>
</Author>
<Author ValidYN="Y"><LastName>Colunas</LastName>
<ForeName>Márcio M</ForeName>
<Initials>MM</Initials>
</Author>
<Author ValidYN="Y"><LastName>Cunha</LastName>
<ForeName>João P S</ForeName>
<Initials>JP</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>Netherlands</Country>
<MedlineTA>Stud Health Technol Inform</MedlineTA>
<NlmUniqueID>9214582</NlmUniqueID>
<ISSNLinking>0926-9630</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>T</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="N" UI="D001132">Arm</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D001676">Biofeedback, Psychology</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D009069">Movement Disorders</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000175">diagnosis</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000534">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D017216">Telemedicine</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D013813">Therapy, Computer-Assisted</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D014584">User-Computer Interface</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="entrez"><Year>2012</Year>
<Month>9</Month>
<Day>4</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2012</Year>
<Month>9</Month>
<Day>4</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2012</Year>
<Month>9</Month>
<Day>28</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">22942034</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/TelematiV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000273 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000273 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= TelematiV1 |flux= PubMed |étape= Curation |type= RBID |clé= pubmed:22942034 |texte= The SWORD tele-rehabilitation system. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i -Sk "pubmed:22942034" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd \ | NlmPubMed2Wicri -a TelematiV1
This area was generated with Dilib version V0.6.31. |