Comparison of rapid load pile testing of driven and CFA piles installed in high OCR clay

Auteurs : M. J. Brown ; J. J. M. Powell

Source :

RBID : Pascal:13-0236606

Descripteurs français

English descriptors

Abstract

The current analysis of rapid load tests (RLT) such as Statnamic is normally based upon empirical correlations with static pile tests in similar soils. In certain soil types, such as clays, the number of case studies used to develop analysis and allow selection of appropriate rate effect correction are limited. Due to these limitations, no distinction is made in the selection of correction factors between pile type and pile installation techniques. In clay soils it is well known that driven piles may have a significantly enhanced capacity over cast in situ piles of similar cross-section. To test the effect of pile installation techniques on RLT analysis, RLT testing and static testing were undertaken on precast driven concrete piles and cast in situ CFA piles installed in high plasticity London Clay. The results show that the installation technique does not appear to affect the magnitude of the rate effects, provided modifications are made to the analysis to account for the previously reported differences in static capacity between different installation techniques. Based upon the findings, it is suggested that a distinction should be made in RLT analysis between pile type and installation techniques, and for existing analysis techniques, further case studies based on rate correction parameters are required, especially in clay soils.

Notice en format standard (ISO 2709)

Pour connaître la documentation sur le format Inist Standard.

pA  
A01 01  1    @0 0038-0806
A02 01      @0 SOIFBE
A03   1    @0 Soils found.
A05       @2 52
A06       @2 6
A08 01  1  ENG  @1 Comparison of rapid load pile testing of driven and CFA piles installed in high OCR clay
A09 01  1  ENG  @1 Special Issue on IS-Kanazawa 9th International Conference on Testing and Design Methods for Deep Foundations
A11 01  1    @1 BROWN (M. J.)
A11 02  1    @1 POWELL (J. J. M.)
A12 01  1    @1 KANEDA (Kazuhiro) @9 ed.
A12 02  1    @1 KOBAYASHI (Shun-ichi) @9 ed.
A14 01      @1 Civil Engineering, University of Dundee @3 GBR @Z 1 aut.
A14 02      @1 Geolabs Limited @3 GBR @Z 2 aut.
A18 01  1    @1 Japanese Geotechnical Society @2 Tokyo @3 JPN @9 org-cong.
A20       @1 1033-1042
A21       @1 2012
A23 01      @0 ENG
A43 01      @1 INIST @2 19776 @5 354000500679670010
A44       @0 0000 @1 © 2013 INIST-CNRS. All rights reserved.
A45       @0 3/4 p.
A47 01  1    @0 13-0236606
A60       @1 P @2 C
A61       @0 A
A64 01  1    @0 Soils and foundations
A66 01      @0 JPN
C01 01    ENG  @0 The current analysis of rapid load tests (RLT) such as Statnamic is normally based upon empirical correlations with static pile tests in similar soils. In certain soil types, such as clays, the number of case studies used to develop analysis and allow selection of appropriate rate effect correction are limited. Due to these limitations, no distinction is made in the selection of correction factors between pile type and pile installation techniques. In clay soils it is well known that driven piles may have a significantly enhanced capacity over cast in situ piles of similar cross-section. To test the effect of pile installation techniques on RLT analysis, RLT testing and static testing were undertaken on precast driven concrete piles and cast in situ CFA piles installed in high plasticity London Clay. The results show that the installation technique does not appear to affect the magnitude of the rate effects, provided modifications are made to the analysis to account for the previously reported differences in static capacity between different installation techniques. Based upon the findings, it is suggested that a distinction should be made in RLT analysis between pile type and installation techniques, and for existing analysis techniques, further case studies based on rate correction parameters are required, especially in clay soils.
C02 01  X    @0 001D14F03
C02 02  X    @0 295
C03 01  X  FRE  @0 Fondation ouvrage @5 02
C03 01  X  ENG  @0 Foundations @5 02
C03 01  X  SPA  @0 Fundación obra @5 02
C03 02  X  FRE  @0 Pieu battu @5 03
C03 02  X  ENG  @0 Driven pile @5 03
C03 02  X  SPA  @0 Pilote hincado @5 03
C03 03  X  FRE  @0 Argile @5 04
C03 03  X  ENG  @0 Clay @5 04
C03 03  X  SPA  @0 Arcilla @5 04
C03 04  X  FRE  @0 Essai charge @5 05
C03 04  X  ENG  @0 Loading test(mechanics) @5 05
C03 04  X  SPA  @0 Ensayo carga @5 05
C03 05  X  FRE  @0 Essai en place @5 06
C03 05  X  ENG  @0 In situ test @5 06
C03 05  X  SPA  @0 Ensayo en sitio @5 06
C03 06  X  FRE  @0 Essai statique @5 07
C03 06  X  ENG  @0 Static test @5 07
C03 06  X  SPA  @0 Ensayo estático @5 07
C03 07  X  FRE  @0 Technique rapide @5 08
C03 07  X  ENG  @0 Rapid technique @5 08
C03 07  X  SPA  @0 Técnica rápida @5 08
C03 08  X  FRE  @0 Etude comparative @5 09
C03 08  X  ENG  @0 Comparative study @5 09
C03 08  X  SPA  @0 Estudio comparativo @5 09
C03 09  X  FRE  @0 Recommandation @5 10
C03 09  X  ENG  @0 Recommendation @5 10
C03 09  X  SPA  @0 Recomendación @5 10
N21       @1 224
N44 01      @1 PSI
N82       @1 PSI
pR  
A30 01  1  ENG  @1 IS-Kanazawa International Conference on Testing and Design Methods for Deep Foundations @2 9 @3 Kanazawa, Ishikawa JPN @4 2012-09-18

Format Inist (serveur)

NO : PASCAL 13-0236606 INIST
ET : Comparison of rapid load pile testing of driven and CFA piles installed in high OCR clay
AU : BROWN (M. J.); POWELL (J. J. M.); KANEDA (Kazuhiro); KOBAYASHI (Shun-ichi)
AF : Civil Engineering, University of Dundee/Royaume-Uni (1 aut.); Geolabs Limited/Royaume-Uni (2 aut.)
DT : Publication en série; Congrès; Niveau analytique
SO : Soils and foundations; ISSN 0038-0806; Coden SOIFBE; Japon; Da. 2012; Vol. 52; No. 6; Pp. 1033-1042; Bibl. 3/4 p.
LA : Anglais
EA : The current analysis of rapid load tests (RLT) such as Statnamic is normally based upon empirical correlations with static pile tests in similar soils. In certain soil types, such as clays, the number of case studies used to develop analysis and allow selection of appropriate rate effect correction are limited. Due to these limitations, no distinction is made in the selection of correction factors between pile type and pile installation techniques. In clay soils it is well known that driven piles may have a significantly enhanced capacity over cast in situ piles of similar cross-section. To test the effect of pile installation techniques on RLT analysis, RLT testing and static testing were undertaken on precast driven concrete piles and cast in situ CFA piles installed in high plasticity London Clay. The results show that the installation technique does not appear to affect the magnitude of the rate effects, provided modifications are made to the analysis to account for the previously reported differences in static capacity between different installation techniques. Based upon the findings, it is suggested that a distinction should be made in RLT analysis between pile type and installation techniques, and for existing analysis techniques, further case studies based on rate correction parameters are required, especially in clay soils.
CC : 001D14F03; 295
FD : Fondation ouvrage; Pieu battu; Argile; Essai charge; Essai en place; Essai statique; Technique rapide; Etude comparative; Recommandation
ED : Foundations; Driven pile; Clay; Loading test(mechanics); In situ test; Static test; Rapid technique; Comparative study; Recommendation
SD : Fundación obra; Pilote hincado; Arcilla; Ensayo carga; Ensayo en sitio; Ensayo estático; Técnica rápida; Estudio comparativo; Recomendación
LO : INIST-19776.354000500679670010
ID : 13-0236606

Links to Exploration step

Pascal:13-0236606

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">Comparison of rapid load pile testing of driven and CFA piles installed in high OCR clay</title>
<author>
<name sortKey="Brown, M J" sort="Brown, M J" uniqKey="Brown M" first="M. J." last="Brown">M. J. Brown</name>
<affiliation>
<inist:fA14 i1="01">
<s1>Civil Engineering, University of Dundee</s1>
<s3>GBR</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author>
<name sortKey="Powell, J J M" sort="Powell, J J M" uniqKey="Powell J" first="J. J. M." last="Powell">J. J. M. Powell</name>
<affiliation>
<inist:fA14 i1="02">
<s1>Geolabs Limited</s1>
<s3>GBR</s3>
<sZ>2 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">13-0236606</idno>
<date when="2012">2012</date>
<idno type="stanalyst">PASCAL 13-0236606 INIST</idno>
<idno type="RBID">Pascal:13-0236606</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000053</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">Comparison of rapid load pile testing of driven and CFA piles installed in high OCR clay</title>
<author>
<name sortKey="Brown, M J" sort="Brown, M J" uniqKey="Brown M" first="M. J." last="Brown">M. J. Brown</name>
<affiliation>
<inist:fA14 i1="01">
<s1>Civil Engineering, University of Dundee</s1>
<s3>GBR</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author>
<name sortKey="Powell, J J M" sort="Powell, J J M" uniqKey="Powell J" first="J. J. M." last="Powell">J. J. M. Powell</name>
<affiliation>
<inist:fA14 i1="02">
<s1>Geolabs Limited</s1>
<s3>GBR</s3>
<sZ>2 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</analytic>
<series>
<title level="j" type="main">Soils and foundations</title>
<title level="j" type="abbreviated">Soils found.</title>
<idno type="ISSN">0038-0806</idno>
<imprint>
<date when="2012">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">Soils and foundations</title>
<title level="j" type="abbreviated">Soils found.</title>
<idno type="ISSN">0038-0806</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Clay</term>
<term>Comparative study</term>
<term>Driven pile</term>
<term>Foundations</term>
<term>In situ test</term>
<term>Loading test(mechanics)</term>
<term>Rapid technique</term>
<term>Recommendation</term>
<term>Static test</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Fondation ouvrage</term>
<term>Pieu battu</term>
<term>Argile</term>
<term>Essai charge</term>
<term>Essai en place</term>
<term>Essai statique</term>
<term>Technique rapide</term>
<term>Etude comparative</term>
<term>Recommandation</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The current analysis of rapid load tests (RLT) such as Statnamic is normally based upon empirical correlations with static pile tests in similar soils. In certain soil types, such as clays, the number of case studies used to develop analysis and allow selection of appropriate rate effect correction are limited. Due to these limitations, no distinction is made in the selection of correction factors between pile type and pile installation techniques. In clay soils it is well known that driven piles may have a significantly enhanced capacity over cast in situ piles of similar cross-section. To test the effect of pile installation techniques on RLT analysis, RLT testing and static testing were undertaken on precast driven concrete piles and cast in situ CFA piles installed in high plasticity London Clay. The results show that the installation technique does not appear to affect the magnitude of the rate effects, provided modifications are made to the analysis to account for the previously reported differences in static capacity between different installation techniques. Based upon the findings, it is suggested that a distinction should be made in RLT analysis between pile type and installation techniques, and for existing analysis techniques, further case studies based on rate correction parameters are required, especially in clay soils.</div>
</front>
</TEI>
<inist>
<standard h6="B">
<pA>
<fA01 i1="01" i2="1">
<s0>0038-0806</s0>
</fA01>
<fA02 i1="01">
<s0>SOIFBE</s0>
</fA02>
<fA03 i2="1">
<s0>Soils found.</s0>
</fA03>
<fA05>
<s2>52</s2>
</fA05>
<fA06>
<s2>6</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG">
<s1>Comparison of rapid load pile testing of driven and CFA piles installed in high OCR clay</s1>
</fA08>
<fA09 i1="01" i2="1" l="ENG">
<s1>Special Issue on IS-Kanazawa 9th International Conference on Testing and Design Methods for Deep Foundations</s1>
</fA09>
<fA11 i1="01" i2="1">
<s1>BROWN (M. J.)</s1>
</fA11>
<fA11 i1="02" i2="1">
<s1>POWELL (J. J. M.)</s1>
</fA11>
<fA12 i1="01" i2="1">
<s1>KANEDA (Kazuhiro)</s1>
<s9>ed.</s9>
</fA12>
<fA12 i1="02" i2="1">
<s1>KOBAYASHI (Shun-ichi)</s1>
<s9>ed.</s9>
</fA12>
<fA14 i1="01">
<s1>Civil Engineering, University of Dundee</s1>
<s3>GBR</s3>
<sZ>1 aut.</sZ>
</fA14>
<fA14 i1="02">
<s1>Geolabs Limited</s1>
<s3>GBR</s3>
<sZ>2 aut.</sZ>
</fA14>
<fA18 i1="01" i2="1">
<s1>Japanese Geotechnical Society</s1>
<s2>Tokyo</s2>
<s3>JPN</s3>
<s9>org-cong.</s9>
</fA18>
<fA20>
<s1>1033-1042</s1>
</fA20>
<fA21>
<s1>2012</s1>
</fA21>
<fA23 i1="01">
<s0>ENG</s0>
</fA23>
<fA43 i1="01">
<s1>INIST</s1>
<s2>19776</s2>
<s5>354000500679670010</s5>
</fA43>
<fA44>
<s0>0000</s0>
<s1>© 2013 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45>
<s0>3/4 p.</s0>
</fA45>
<fA47 i1="01" i2="1">
<s0>13-0236606</s0>
</fA47>
<fA60>
<s1>P</s1>
<s2>C</s2>
</fA60>
<fA61>
<s0>A</s0>
</fA61>
<fA64 i1="01" i2="1">
<s0>Soils and foundations</s0>
</fA64>
<fA66 i1="01">
<s0>JPN</s0>
</fA66>
<fC01 i1="01" l="ENG">
<s0>The current analysis of rapid load tests (RLT) such as Statnamic is normally based upon empirical correlations with static pile tests in similar soils. In certain soil types, such as clays, the number of case studies used to develop analysis and allow selection of appropriate rate effect correction are limited. Due to these limitations, no distinction is made in the selection of correction factors between pile type and pile installation techniques. In clay soils it is well known that driven piles may have a significantly enhanced capacity over cast in situ piles of similar cross-section. To test the effect of pile installation techniques on RLT analysis, RLT testing and static testing were undertaken on precast driven concrete piles and cast in situ CFA piles installed in high plasticity London Clay. The results show that the installation technique does not appear to affect the magnitude of the rate effects, provided modifications are made to the analysis to account for the previously reported differences in static capacity between different installation techniques. Based upon the findings, it is suggested that a distinction should be made in RLT analysis between pile type and installation techniques, and for existing analysis techniques, further case studies based on rate correction parameters are required, especially in clay soils.</s0>
</fC01>
<fC02 i1="01" i2="X">
<s0>001D14F03</s0>
</fC02>
<fC02 i1="02" i2="X">
<s0>295</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE">
<s0>Fondation ouvrage</s0>
<s5>02</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG">
<s0>Foundations</s0>
<s5>02</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA">
<s0>Fundación obra</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE">
<s0>Pieu battu</s0>
<s5>03</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG">
<s0>Driven pile</s0>
<s5>03</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA">
<s0>Pilote hincado</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE">
<s0>Argile</s0>
<s5>04</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG">
<s0>Clay</s0>
<s5>04</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA">
<s0>Arcilla</s0>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE">
<s0>Essai charge</s0>
<s5>05</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG">
<s0>Loading test(mechanics)</s0>
<s5>05</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA">
<s0>Ensayo carga</s0>
<s5>05</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE">
<s0>Essai en place</s0>
<s5>06</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG">
<s0>In situ test</s0>
<s5>06</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA">
<s0>Ensayo en sitio</s0>
<s5>06</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE">
<s0>Essai statique</s0>
<s5>07</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG">
<s0>Static test</s0>
<s5>07</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA">
<s0>Ensayo estático</s0>
<s5>07</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE">
<s0>Technique rapide</s0>
<s5>08</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG">
<s0>Rapid technique</s0>
<s5>08</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA">
<s0>Técnica rápida</s0>
<s5>08</s5>
</fC03>
<fC03 i1="08" i2="X" l="FRE">
<s0>Etude comparative</s0>
<s5>09</s5>
</fC03>
<fC03 i1="08" i2="X" l="ENG">
<s0>Comparative study</s0>
<s5>09</s5>
</fC03>
<fC03 i1="08" i2="X" l="SPA">
<s0>Estudio comparativo</s0>
<s5>09</s5>
</fC03>
<fC03 i1="09" i2="X" l="FRE">
<s0>Recommandation</s0>
<s5>10</s5>
</fC03>
<fC03 i1="09" i2="X" l="ENG">
<s0>Recommendation</s0>
<s5>10</s5>
</fC03>
<fC03 i1="09" i2="X" l="SPA">
<s0>Recomendación</s0>
<s5>10</s5>
</fC03>
<fN21>
<s1>224</s1>
</fN21>
<fN44 i1="01">
<s1>PSI</s1>
</fN44>
<fN82>
<s1>PSI</s1>
</fN82>
</pA>
<pR>
<fA30 i1="01" i2="1" l="ENG">
<s1>IS-Kanazawa International Conference on Testing and Design Methods for Deep Foundations</s1>
<s2>9</s2>
<s3>Kanazawa, Ishikawa JPN</s3>
<s4>2012-09-18</s4>
</fA30>
</pR>
</standard>
<server>
<NO>PASCAL 13-0236606 INIST</NO>
<ET>Comparison of rapid load pile testing of driven and CFA piles installed in high OCR clay</ET>
<AU>BROWN (M. J.); POWELL (J. J. M.); KANEDA (Kazuhiro); KOBAYASHI (Shun-ichi)</AU>
<AF>Civil Engineering, University of Dundee/Royaume-Uni (1 aut.); Geolabs Limited/Royaume-Uni (2 aut.)</AF>
<DT>Publication en série; Congrès; Niveau analytique</DT>
<SO>Soils and foundations; ISSN 0038-0806; Coden SOIFBE; Japon; Da. 2012; Vol. 52; No. 6; Pp. 1033-1042; Bibl. 3/4 p.</SO>
<LA>Anglais</LA>
<EA>The current analysis of rapid load tests (RLT) such as Statnamic is normally based upon empirical correlations with static pile tests in similar soils. In certain soil types, such as clays, the number of case studies used to develop analysis and allow selection of appropriate rate effect correction are limited. Due to these limitations, no distinction is made in the selection of correction factors between pile type and pile installation techniques. In clay soils it is well known that driven piles may have a significantly enhanced capacity over cast in situ piles of similar cross-section. To test the effect of pile installation techniques on RLT analysis, RLT testing and static testing were undertaken on precast driven concrete piles and cast in situ CFA piles installed in high plasticity London Clay. The results show that the installation technique does not appear to affect the magnitude of the rate effects, provided modifications are made to the analysis to account for the previously reported differences in static capacity between different installation techniques. Based upon the findings, it is suggested that a distinction should be made in RLT analysis between pile type and installation techniques, and for existing analysis techniques, further case studies based on rate correction parameters are required, especially in clay soils.</EA>
<CC>001D14F03; 295</CC>
<FD>Fondation ouvrage; Pieu battu; Argile; Essai charge; Essai en place; Essai statique; Technique rapide; Etude comparative; Recommandation</FD>
<ED>Foundations; Driven pile; Clay; Loading test(mechanics); In situ test; Static test; Rapid technique; Comparative study; Recommendation</ED>
<SD>Fundación obra; Pilote hincado; Arcilla; Ensayo carga; Ensayo en sitio; Ensayo estático; Técnica rápida; Estudio comparativo; Recomendación</SD>
<LO>INIST-19776.354000500679670010</LO>
<ID>13-0236606</ID>
</server>
</inist>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/OcrV1/Data/PascalFrancis/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000053 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Corpus/biblio.hfd -nk 000053 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    OcrV1
   |flux=    PascalFrancis
   |étape=   Corpus
   |type=    RBID
   |clé=     Pascal:13-0236606
   |texte=   Comparison of rapid load pile testing of driven and CFA piles installed in high OCR clay
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Sat Nov 11 16:53:45 2017. Site generation: Mon Mar 11 23:15:16 2024