Low‐cost wearable low‐vision aid using a handmade retinal light‐scanning microdisplay

Identifieur interne : 000191 ( Istex/Corpus ); précédent : 000190; suivant : 000192

Low‐cost wearable low‐vision aid using a handmade retinal light‐scanning microdisplay

Auteurs : Ryland C. Bryant ; Eric J. Seibel ; Cameron M. Lee ; Konrad E. Schroder

Source :

RBID : ISTEX:D7AC19375AEAA7BCDF76B41777CCBCA90B57EA78

English descriptors

Abstract

Abstract— The Wearable Low Vision Aid (WLVA) is a portable system that uses machine vision to track potential walking hazards for the visually impaired. A scanning fiber display couples a laser diode to a vibrating optical fiber that projects a virtual image onto the retina to display warning icons that the visually impaired can recognize. Initial low‐vision subject testing has given promising results for this low‐cost assistive device.

Url:
DOI: 10.1889/1.1847738

Links to Exploration step

ISTEX:D7AC19375AEAA7BCDF76B41777CCBCA90B57EA78

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Low‐cost wearable low‐vision aid using a handmade retinal light‐scanning microdisplay</title>
<author>
<name sortKey="Bryant, Ryland C" sort="Bryant, Ryland C" uniqKey="Bryant R" first="Ryland C." last="Bryant">Ryland C. Bryant</name>
<affiliation>
<mods:affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Seibel, Eric J" sort="Seibel, Eric J" uniqKey="Seibel E" first="Eric J." last="Seibel">Eric J. Seibel</name>
<affiliation>
<mods:affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Lee, Cameron M" sort="Lee, Cameron M" uniqKey="Lee C" first="Cameron M." last="Lee">Cameron M. Lee</name>
<affiliation>
<mods:affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Schroder, Konrad E" sort="Schroder, Konrad E" uniqKey="Schroder K" first="Konrad E." last="Schroder">Konrad E. Schroder</name>
<affiliation>
<mods:affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</mods:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:D7AC19375AEAA7BCDF76B41777CCBCA90B57EA78</idno>
<date when="2004" year="2004">2004</date>
<idno type="doi">10.1889/1.1847738</idno>
<idno type="url">https://api.istex.fr/document/D7AC19375AEAA7BCDF76B41777CCBCA90B57EA78/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000191</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Low‐cost wearable low‐vision aid using a handmade retinal light‐scanning microdisplay</title>
<author>
<name sortKey="Bryant, Ryland C" sort="Bryant, Ryland C" uniqKey="Bryant R" first="Ryland C." last="Bryant">Ryland C. Bryant</name>
<affiliation>
<mods:affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Seibel, Eric J" sort="Seibel, Eric J" uniqKey="Seibel E" first="Eric J." last="Seibel">Eric J. Seibel</name>
<affiliation>
<mods:affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Lee, Cameron M" sort="Lee, Cameron M" uniqKey="Lee C" first="Cameron M." last="Lee">Cameron M. Lee</name>
<affiliation>
<mods:affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Schroder, Konrad E" sort="Schroder, Konrad E" uniqKey="Schroder K" first="Konrad E." last="Schroder">Konrad E. Schroder</name>
<affiliation>
<mods:affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</mods:affiliation>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Journal of the Society for Information Display</title>
<idno type="ISSN">1071-0922</idno>
<idno type="eISSN">1938-3657</idno>
<imprint>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2004-12">2004-12</date>
<biblScope unit="volume">12</biblScope>
<biblScope unit="issue">4</biblScope>
<biblScope unit="page" from="397">397</biblScope>
<biblScope unit="page" to="404">404</biblScope>
</imprint>
<idno type="ISSN">1071-0922</idno>
</series>
<idno type="istex">D7AC19375AEAA7BCDF76B41777CCBCA90B57EA78</idno>
<idno type="DOI">10.1889/1.1847738</idno>
<idno type="ArticleID">JSID1057</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">1071-0922</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Low vision</term>
<term>legally blind</term>
<term>machine vision</term>
<term>microdisplay</term>
<term>wearable computer</term>
</keywords>
</textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Abstract— The Wearable Low Vision Aid (WLVA) is a portable system that uses machine vision to track potential walking hazards for the visually impaired. A scanning fiber display couples a laser diode to a vibrating optical fiber that projects a virtual image onto the retina to display warning icons that the visually impaired can recognize. Initial low‐vision subject testing has given promising results for this low‐cost assistive device.</div>
</front>
</TEI>
<istex>
<corpusName>wiley</corpusName>
<author>
<json:item>
<name>Ryland C. Bryant</name>
<affiliations>
<json:string>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</json:string>
</affiliations>
</json:item>
<json:item>
<name>Eric J. Seibel</name>
<affiliations>
<json:string>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</json:string>
</affiliations>
</json:item>
<json:item>
<name>Cameron M. Lee</name>
<affiliations>
<json:string>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</json:string>
</affiliations>
</json:item>
<json:item>
<name>Konrad E. Schroder</name>
<affiliations>
<json:string>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</json:string>
</affiliations>
</json:item>
</author>
<subject>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>Low vision</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>legally blind</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>microdisplay</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>machine vision</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>wearable computer</value>
</json:item>
</subject>
<articleId>
<json:string>JSID1057</json:string>
</articleId>
<language>
<json:string>eng</json:string>
</language>
<abstract>Abstract— The Wearable Low Vision Aid (WLVA) is a portable system that uses machine vision to track potential walking hazards for the visually impaired. A scanning fiber display couples a laser diode to a vibrating optical fiber that projects a virtual image onto the retina to display warning icons that the visually impaired can recognize. Initial low‐vision subject testing has given promising results for this low‐cost assistive device.</abstract>
<qualityIndicators>
<score>6.944</score>
<pdfVersion>1.6</pdfVersion>
<pdfPageSize>612 x 792 pts (letter)</pdfPageSize>
<refBibsNative>true</refBibsNative>
<keywordCount>5</keywordCount>
<abstractCharCount>440</abstractCharCount>
<pdfWordCount>4628</pdfWordCount>
<pdfCharCount>27446</pdfCharCount>
<pdfPageCount>8</pdfPageCount>
<abstractWordCount>68</abstractWordCount>
</qualityIndicators>
<title>Low‐cost wearable low‐vision aid using a handmade retinal light‐scanning microdisplay</title>
<genre.original>
<json:string>article</json:string>
</genre.original>
<genre>
<json:string>article</json:string>
</genre>
<host>
<volume>12</volume>
<publisherId>
<json:string>JSID</json:string>
</publisherId>
<pages>
<total>8</total>
<last>404</last>
<first>397</first>
</pages>
<issn>
<json:string>1071-0922</json:string>
</issn>
<issue>4</issue>
<genre>
<json:string>journal</json:string>
</genre>
<language>
<json:string>unknown</json:string>
</language>
<eissn>
<json:string>1938-3657</json:string>
</eissn>
<title>Journal of the Society for Information Display</title>
<doi>
<json:string>10.1002/(ISSN)1938-3657</json:string>
</doi>
</host>
<publicationDate>2004</publicationDate>
<copyrightDate>2004</copyrightDate>
<doi>
<json:string>10.1889/1.1847738</json:string>
</doi>
<id>D7AC19375AEAA7BCDF76B41777CCBCA90B57EA78</id>
<fulltext>
<json:item>
<original>true</original>
<mimetype>application/pdf</mimetype>
<extension>pdf</extension>
<uri>https://api.istex.fr/document/D7AC19375AEAA7BCDF76B41777CCBCA90B57EA78/fulltext/pdf</uri>
</json:item>
<json:item>
<original>false</original>
<mimetype>application/zip</mimetype>
<extension>zip</extension>
<uri>https://api.istex.fr/document/D7AC19375AEAA7BCDF76B41777CCBCA90B57EA78/fulltext/zip</uri>
</json:item>
<istex:fulltextTEI uri="https://api.istex.fr/document/D7AC19375AEAA7BCDF76B41777CCBCA90B57EA78/fulltext/tei">
<teiHeader>
<fileDesc>
<titleStmt>
<title level="a" type="main" xml:lang="en">Low‐cost wearable low‐vision aid using a handmade retinal light‐scanning microdisplay</title>
</titleStmt>
<publicationStmt>
<authority>ISTEX</authority>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<availability>
<p>WILEY</p>
</availability>
<date>2004</date>
</publicationStmt>
<sourceDesc>
<biblStruct type="inbook">
<analytic>
<title level="a" type="main" xml:lang="en">Low‐cost wearable low‐vision aid using a handmade retinal light‐scanning microdisplay</title>
<author>
<persName>
<forename type="first">Ryland C.</forename>
<surname>Bryant</surname>
</persName>
<note type="correspondence">
<p>Correspondence:</p>
</note>
<affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</affiliation>
</author>
<author>
<persName>
<forename type="first">Eric J.</forename>
<surname>Seibel</surname>
</persName>
<affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</affiliation>
</author>
<author>
<persName>
<forename type="first">Cameron M.</forename>
<surname>Lee</surname>
</persName>
<affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</affiliation>
</author>
<author>
<persName>
<forename type="first">Konrad E.</forename>
<surname>Schroder</surname>
</persName>
<affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</affiliation>
</author>
</analytic>
<monogr>
<title level="j">Journal of the Society for Information Display</title>
<idno type="pISSN">1071-0922</idno>
<idno type="eISSN">1938-3657</idno>
<idno type="DOI">10.1002/(ISSN)1938-3657</idno>
<imprint>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2004-12"></date>
<biblScope unit="volume">12</biblScope>
<biblScope unit="issue">4</biblScope>
<biblScope unit="page" from="397">397</biblScope>
<biblScope unit="page" to="404">404</biblScope>
</imprint>
</monogr>
<idno type="istex">D7AC19375AEAA7BCDF76B41777CCBCA90B57EA78</idno>
<idno type="DOI">10.1889/1.1847738</idno>
<idno type="ArticleID">JSID1057</idno>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<creation>
<date>2004</date>
</creation>
<langUsage>
<language ident="en">en</language>
</langUsage>
<abstract xml:lang="en">
<p>Abstract— The Wearable Low Vision Aid (WLVA) is a portable system that uses machine vision to track potential walking hazards for the visually impaired. A scanning fiber display couples a laser diode to a vibrating optical fiber that projects a virtual image onto the retina to display warning icons that the visually impaired can recognize. Initial low‐vision subject testing has given promising results for this low‐cost assistive device.</p>
</abstract>
<textClass xml:lang="en">
<keywords scheme="keyword">
<list>
<head>keywords</head>
<item>
<term>Low vision</term>
</item>
<item>
<term>legally blind</term>
</item>
<item>
<term>microdisplay</term>
</item>
<item>
<term>machine vision</term>
</item>
<item>
<term>wearable computer</term>
</item>
</list>
</keywords>
</textClass>
</profileDesc>
<revisionDesc>
<change when="2004-12">Published</change>
</revisionDesc>
</teiHeader>
</istex:fulltextTEI>
<json:item>
<original>false</original>
<mimetype>text/plain</mimetype>
<extension>txt</extension>
<uri>https://api.istex.fr/document/D7AC19375AEAA7BCDF76B41777CCBCA90B57EA78/fulltext/txt</uri>
</json:item>
</fulltext>
<metadata>
<istex:metadataXml wicri:clean="Wiley, elements deleted: body">
<istex:xmlDeclaration>version="1.0" encoding="UTF-8" standalone="yes"</istex:xmlDeclaration>
<istex:document>
<component version="2.0" type="serialArticle" xml:lang="en">
<header>
<publicationMeta level="product">
<publisherInfo>
<publisherName>Blackwell Publishing Ltd</publisherName>
<publisherLoc>Oxford, UK</publisherLoc>
</publisherInfo>
<doi origin="wiley" registered="yes">10.1002/(ISSN)1938-3657</doi>
<issn type="print">1071-0922</issn>
<issn type="electronic">1938-3657</issn>
<idGroup>
<id type="product" value="JSID"></id>
<id type="publisherDivision" value="ST"></id>
</idGroup>
<titleGroup>
<title type="main" sort="JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY">Journal of the Society for Information Display</title>
</titleGroup>
</publicationMeta>
<publicationMeta level="part" position="12104">
<doi origin="wiley">10.1002/jsid.2004.12.issue-4</doi>
<numberingGroup>
<numbering type="journalVolume" number="12">12</numbering>
<numbering type="journalIssue" number="4">4</numbering>
</numberingGroup>
<coverDate startDate="2004-12">December 2004</coverDate>
</publicationMeta>
<publicationMeta level="unit" type="article" position="9" status="forIssue">
<doi origin="wiley">10.1889/1.1847738</doi>
<idGroup>
<id type="unit" value="JSID1057"></id>
</idGroup>
<countGroup>
<count type="pageTotal" number="8"></count>
</countGroup>
<titleGroup>
<title type="tocHeading1">SELECTED EXTENDED PAPERS FROM THE 2004 SID INTERNATIONAL SYMPOSIUM (SID '04)</title>
</titleGroup>
<copyright>2004 Society for Information Display</copyright>
<eventGroup>
<event type="xmlConverted" agent="Converter:BPG_TO_WML3G version:3.1.5 mode:FullText" date="2012-06-27"></event>
<event type="publishedOnlineFinalForm" date="2012-06-18"></event>
<event type="firstOnline" date="2012-06-18"></event>
<event type="xmlConverted" agent="Converter:WILEY_ML3G_TO_WILEY_ML3GV2 version:3.8.8" date="2014-02-01"></event>
<event type="xmlConverted" agent="Converter:WML3G_To_WML3G version:4.1.7 mode:FullText,remove_FC" date="2014-11-01"></event>
</eventGroup>
<numberingGroup>
<numbering type="pageFirst" number="397">397</numbering>
<numbering type="pageLast" number="404">404</numbering>
</numberingGroup>
<correspondenceTo>
<email>ryland@u.washington.edu</email>
</correspondenceTo>
<linkGroup>
<link type="toTypesetVersion" href="file:JSID.JSID1057.pdf"></link>
</linkGroup>
</publicationMeta>
<contentMeta>
<countGroup>
<count type="referenceTotal" number="13"></count>
<count type="linksCrossRef" number="5"></count>
</countGroup>
<titleGroup>
<title type="main">Low‐cost wearable low‐vision aid using a handmade retinal light‐scanning microdisplay</title>
</titleGroup>
<creators>
<creator creatorRole="author" xml:id="cr1" affiliationRef="#a1" corresponding="yes">
<personName>
<givenNames>Ryland C.</givenNames>
<familyName>Bryant</familyName>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr2" affiliationRef="#a1">
<personName>
<givenNames>Eric J.</givenNames>
<familyName>Seibel</familyName>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr3" affiliationRef="#a1">
<personName>
<givenNames>Cameron M.</givenNames>
<familyName>Lee</familyName>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr4" affiliationRef="#a1">
<personName>
<givenNames>Konrad E.</givenNames>
<familyName>Schroder</familyName>
</personName>
</creator>
</creators>
<affiliationGroup>
<affiliation xml:id="a1">
<unparsedAffiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</unparsedAffiliation>
</affiliation>
</affiliationGroup>
<keywordGroup xml:lang="en">
<keyword xml:id="k1">Low vision</keyword>
<keyword xml:id="k2">legally blind</keyword>
<keyword xml:id="k3">microdisplay</keyword>
<keyword xml:id="k4">machine vision</keyword>
<keyword xml:id="k5">wearable computer</keyword>
</keywordGroup>
<abstractGroup>
<abstract type="main" xml:lang="en">
<p>
<b>Abstract—</b>
The Wearable Low Vision Aid (WLVA) is a portable system that uses machine vision to track potential walking hazards for the visually impaired. A scanning fiber display couples a laser diode to a vibrating optical fiber that projects a virtual image onto the retina to display warning icons that the visually impaired can recognize. Initial low‐vision subject testing has given promising results for this low‐cost assistive device.</p>
</abstract>
</abstractGroup>
</contentMeta>
</header>
</component>
</istex:document>
</istex:metadataXml>
<mods version="3.6">
<titleInfo lang="en">
<title>Low‐cost wearable low‐vision aid using a handmade retinal light‐scanning microdisplay</title>
</titleInfo>
<titleInfo type="alternative" contentType="CDATA" lang="en">
<title>Low‐cost wearable low‐vision aid using a handmade retinal light‐scanning microdisplay</title>
</titleInfo>
<name type="personal">
<namePart type="given">Ryland C.</namePart>
<namePart type="family">Bryant</namePart>
<affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</affiliation>
<description>Correspondence: </description>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Eric J.</namePart>
<namePart type="family">Seibel</namePart>
<affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Cameron M.</namePart>
<namePart type="family">Lee</namePart>
<affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Konrad E.</namePart>
<namePart type="family">Schroder</namePart>
<affiliation>Human Interface Technology Laboratory, 215 Fluke Hall, UW Mailbox 352142, Seattle, WA 98195‐2142</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<typeOfResource>text</typeOfResource>
<genre type="article" displayLabel="article"></genre>
<originInfo>
<publisher>Blackwell Publishing Ltd</publisher>
<place>
<placeTerm type="text">Oxford, UK</placeTerm>
</place>
<dateIssued encoding="w3cdtf">2004-12</dateIssued>
<copyrightDate encoding="w3cdtf">2004</copyrightDate>
</originInfo>
<language>
<languageTerm type="code" authority="rfc3066">en</languageTerm>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<internetMediaType>text/html</internetMediaType>
<extent unit="references">13</extent>
</physicalDescription>
<abstract lang="en">Abstract— The Wearable Low Vision Aid (WLVA) is a portable system that uses machine vision to track potential walking hazards for the visually impaired. A scanning fiber display couples a laser diode to a vibrating optical fiber that projects a virtual image onto the retina to display warning icons that the visually impaired can recognize. Initial low‐vision subject testing has given promising results for this low‐cost assistive device.</abstract>
<subject lang="en">
<genre>keywords</genre>
<topic>Low vision</topic>
<topic>legally blind</topic>
<topic>microdisplay</topic>
<topic>machine vision</topic>
<topic>wearable computer</topic>
</subject>
<relatedItem type="host">
<titleInfo>
<title>Journal of the Society for Information Display</title>
</titleInfo>
<genre type="journal">journal</genre>
<identifier type="ISSN">1071-0922</identifier>
<identifier type="eISSN">1938-3657</identifier>
<identifier type="DOI">10.1002/(ISSN)1938-3657</identifier>
<identifier type="PublisherID">JSID</identifier>
<part>
<date>2004</date>
<detail type="volume">
<caption>vol.</caption>
<number>12</number>
</detail>
<detail type="issue">
<caption>no.</caption>
<number>4</number>
</detail>
<extent unit="pages">
<start>397</start>
<end>404</end>
<total>8</total>
</extent>
</part>
</relatedItem>
<identifier type="istex">D7AC19375AEAA7BCDF76B41777CCBCA90B57EA78</identifier>
<identifier type="DOI">10.1889/1.1847738</identifier>
<identifier type="ArticleID">JSID1057</identifier>
<accessCondition type="use and reproduction" contentType="copyright">2004 Society for Information Display</accessCondition>
<recordInfo>
<recordContentSource>WILEY</recordContentSource>
<recordOrigin>Blackwell Publishing Ltd</recordOrigin>
</recordInfo>
</mods>
</metadata>
<serie></serie>
</istex>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/OcrV1/Data/Istex/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000191 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Corpus/biblio.hfd -nk 000191 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    OcrV1
   |flux=    Istex
   |étape=   Corpus
   |type=    RBID
   |clé=     ISTEX:D7AC19375AEAA7BCDF76B41777CCBCA90B57EA78
   |texte=   Low‐cost wearable low‐vision aid using a handmade retinal light‐scanning microdisplay
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Sat Nov 11 16:53:45 2017. Site generation: Mon Mar 11 23:15:16 2024