Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

[Long-term follow-up following posterior chamber lens implantation with defective or absent posterior chamber].

Identifieur interne : 002275 ( PubMed/Curation ); précédent : 002274; suivant : 002276

[Long-term follow-up following posterior chamber lens implantation with defective or absent posterior chamber].

Auteurs : R. Hennekes ; T. Pham Duy

Source :

RBID : pubmed:2684821

English descriptors

Abstract

41 patients were follow up in whom a posterior chamber lens was implanted despite of ruptured posterior capsule. Follow-up period was 9 months to 5 years: 30 lenses were well centered, 7 were slightly decentrated, 2 were strongly decentrated. In 2 cases the lens was luxated into the vitreous. CME was observed in two cases and retinal detachment in 5 cases. In 6 selected patients without posterior capsule, a 2-loop PCL (Simcoe-type) was implanted by controlled suture-fixation into the ciliary sulcus. The inferior haptic was sutured directly in the 6 o'clock position while the superior haptic (12 o'clock) was fixed indirectly by an "iris flap" (made from the "iridectomy") which was turned posteriorly. Follow-up period of 1-2 years: no decentration, vitreous in the anterior chamber in 2 cases.

PubMed: 2684821

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:2684821

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">[Long-term follow-up following posterior chamber lens implantation with defective or absent posterior chamber].</title>
<author>
<name sortKey="Hennekes, R" sort="Hennekes, R" uniqKey="Hennekes R" first="R" last="Hennekes">R. Hennekes</name>
</author>
<author>
<name sortKey="Pham Duy, T" sort="Pham Duy, T" uniqKey="Pham Duy T" first="T" last="Pham Duy">T. Pham Duy</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1989">1989</date>
<idno type="RBID">pubmed:2684821</idno>
<idno type="pmid">2684821</idno>
<idno type="wicri:Area/PubMed/Corpus">002275</idno>
<idno type="wicri:Area/PubMed/Curation">002275</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">[Long-term follow-up following posterior chamber lens implantation with defective or absent posterior chamber].</title>
<author>
<name sortKey="Hennekes, R" sort="Hennekes, R" uniqKey="Hennekes R" first="R" last="Hennekes">R. Hennekes</name>
</author>
<author>
<name sortKey="Pham Duy, T" sort="Pham Duy, T" uniqKey="Pham Duy T" first="T" last="Pham Duy">T. Pham Duy</name>
</author>
</analytic>
<series>
<title level="j">Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft</title>
<idno type="ISSN">0723-8045</idno>
<imprint>
<date when="1989" type="published">1989</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Intraoperative Complications (surgery)</term>
<term>Lens Capsule, Crystalline (injuries)</term>
<term>Lens, Crystalline (injuries)</term>
<term>Lenses, Intraocular</term>
<term>Rupture</term>
<term>Suture Techniques</term>
<term>Vitrectomy</term>
</keywords>
<keywords scheme="MESH" qualifier="injuries" xml:lang="en">
<term>Lens Capsule, Crystalline</term>
<term>Lens, Crystalline</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Intraoperative Complications</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Rupture</term>
<term>Suture Techniques</term>
<term>Vitrectomy</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">41 patients were follow up in whom a posterior chamber lens was implanted despite of ruptured posterior capsule. Follow-up period was 9 months to 5 years: 30 lenses were well centered, 7 were slightly decentrated, 2 were strongly decentrated. In 2 cases the lens was luxated into the vitreous. CME was observed in two cases and retinal detachment in 5 cases. In 6 selected patients without posterior capsule, a 2-loop PCL (Simcoe-type) was implanted by controlled suture-fixation into the ciliary sulcus. The inferior haptic was sutured directly in the 6 o'clock position while the superior haptic (12 o'clock) was fixed indirectly by an "iris flap" (made from the "iridectomy") which was turned posteriorly. Follow-up period of 1-2 years: no decentration, vitreous in the anterior chamber in 2 cases.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">2684821</PMID>
<DateCreated>
<Year>1990</Year>
<Month>01</Month>
<Day>04</Day>
</DateCreated>
<DateCompleted>
<Year>1990</Year>
<Month>01</Month>
<Day>04</Day>
</DateCompleted>
<DateRevised>
<Year>2006</Year>
<Month>11</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0723-8045</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>86</Volume>
<Issue>5</Issue>
<PubDate>
<Year>1989</Year>
</PubDate>
</JournalIssue>
<Title>Fortschritte der Ophthalmologie : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft</Title>
<ISOAbbreviation>Fortschr Ophthalmol</ISOAbbreviation>
</Journal>
<ArticleTitle>[Long-term follow-up following posterior chamber lens implantation with defective or absent posterior chamber].</ArticleTitle>
<Pagination>
<MedlinePgn>426-8</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>41 patients were follow up in whom a posterior chamber lens was implanted despite of ruptured posterior capsule. Follow-up period was 9 months to 5 years: 30 lenses were well centered, 7 were slightly decentrated, 2 were strongly decentrated. In 2 cases the lens was luxated into the vitreous. CME was observed in two cases and retinal detachment in 5 cases. In 6 selected patients without posterior capsule, a 2-loop PCL (Simcoe-type) was implanted by controlled suture-fixation into the ciliary sulcus. The inferior haptic was sutured directly in the 6 o'clock position while the superior haptic (12 o'clock) was fixed indirectly by an "iris flap" (made from the "iridectomy") which was turned posteriorly. Follow-up period of 1-2 years: no decentration, vitreous in the anterior chamber in 2 cases.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Hennekes</LastName>
<ForeName>R</ForeName>
<Initials>R</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Pham Duy</LastName>
<ForeName>T</ForeName>
<Initials>T</Initials>
</Author>
</AuthorList>
<Language>ger</Language>
<PublicationTypeList>
<PublicationType UI="D004740">English Abstract</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<VernacularTitle>Langzeitbeobachtungen nach HKL-Implantation mit defekter oder fehlender Hinterkapsel.</VernacularTitle>
</Article>
<MedlineJournalInfo>
<Country>GERMANY, WEST</Country>
<MedlineTA>Fortschr Ophthalmol</MedlineTA>
<NlmUniqueID>8302807</NlmUniqueID>
<ISSNLinking>0723-8045</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005500">Follow-Up Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007431">Intraoperative Complications</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007903">Lens Capsule, Crystalline</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000293">injuries</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007908">Lens, Crystalline</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000293">injuries</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012421">Rupture</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D013536">Suture Techniques</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014821">Vitrectomy</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1989</Year>
<Month>1</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1989</Year>
<Month>1</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1989</Year>
<Month>1</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">2684821</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002275 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 002275 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:2684821
   |texte=   [Long-term follow-up following posterior chamber lens implantation with defective or absent posterior chamber].
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:2684821" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024