Prospective evaluation of a plate haptic toric intraocular lens.

Identifieur interne : 001D52 ( PubMed/Curation ); précédent : 001D51; suivant : 001D53

Prospective evaluation of a plate haptic toric intraocular lens.

Auteurs : M. Leyland [Royaume-Uni] ; E. Zinicola ; P. Bloom ; N. Lee

Source :

RBID : pubmed:11339591

English descriptors

Abstract

Standard intraocular lenses (IOL) only correct the spherical component of aphakic refractive error. This study describes clinical experience with a foldable, injectable, toric IOL.

DOI: 10.1038/eye.2001.61
PubMed: 11339591

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:11339591

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Prospective evaluation of a plate haptic toric intraocular lens.</title>
<author>
<name sortKey="Leyland, M" sort="Leyland, M" uniqKey="Leyland M" first="M" last="Leyland">M. Leyland</name>
<affiliation wicri:level="1">
<nlm:affiliation>Hillingdon Hospital NHS Trust, Uxbridge, UK.</nlm:affiliation>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Hillingdon Hospital NHS Trust, Uxbridge</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Zinicola, E" sort="Zinicola, E" uniqKey="Zinicola E" first="E" last="Zinicola">E. Zinicola</name>
</author>
<author>
<name sortKey="Bloom, P" sort="Bloom, P" uniqKey="Bloom P" first="P" last="Bloom">P. Bloom</name>
</author>
<author>
<name sortKey="Lee, N" sort="Lee, N" uniqKey="Lee N" first="N" last="Lee">N. Lee</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2001">2001</date>
<idno type="RBID">pubmed:11339591</idno>
<idno type="pmid">11339591</idno>
<idno type="doi">10.1038/eye.2001.61</idno>
<idno type="wicri:Area/PubMed/Corpus">001D52</idno>
<idno type="wicri:Area/PubMed/Curation">001D52</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Prospective evaluation of a plate haptic toric intraocular lens.</title>
<author>
<name sortKey="Leyland, M" sort="Leyland, M" uniqKey="Leyland M" first="M" last="Leyland">M. Leyland</name>
<affiliation wicri:level="1">
<nlm:affiliation>Hillingdon Hospital NHS Trust, Uxbridge, UK.</nlm:affiliation>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Hillingdon Hospital NHS Trust, Uxbridge</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Zinicola, E" sort="Zinicola, E" uniqKey="Zinicola E" first="E" last="Zinicola">E. Zinicola</name>
</author>
<author>
<name sortKey="Bloom, P" sort="Bloom, P" uniqKey="Bloom P" first="P" last="Bloom">P. Bloom</name>
</author>
<author>
<name sortKey="Lee, N" sort="Lee, N" uniqKey="Lee N" first="N" last="Lee">N. Lee</name>
</author>
</analytic>
<series>
<title level="j">Eye (London, England)</title>
<idno type="ISSN">0950-222X</idno>
<imprint>
<date when="2001" type="published">2001</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Astigmatism (therapy)</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular (methods)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Phacoemulsification</term>
<term>Postoperative Period</term>
<term>Prospective Studies</term>
<term>Refraction, Ocular</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Lens Implantation, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="therapy" xml:lang="en">
<term>Astigmatism</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Phacoemulsification</term>
<term>Postoperative Period</term>
<term>Prospective Studies</term>
<term>Refraction, Ocular</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Standard intraocular lenses (IOL) only correct the spherical component of aphakic refractive error. This study describes clinical experience with a foldable, injectable, toric IOL.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">11339591</PMID>
<DateCreated>
<Year>2001</Year>
<Month>05</Month>
<Day>07</Day>
</DateCreated>
<DateCompleted>
<Year>2001</Year>
<Month>05</Month>
<Day>31</Day>
</DateCompleted>
<DateRevised>
<Year>2009</Year>
<Month>11</Month>
<Day>03</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0950-222X</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>15</Volume>
<Issue>Pt 2</Issue>
<PubDate>
<Year>2001</Year>
<Month>Apr</Month>
</PubDate>
</JournalIssue>
<Title>Eye (London, England)</Title>
<ISOAbbreviation>Eye (Lond)</ISOAbbreviation>
</Journal>
<ArticleTitle>Prospective evaluation of a plate haptic toric intraocular lens.</ArticleTitle>
<Pagination>
<MedlinePgn>202-5</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">Standard intraocular lenses (IOL) only correct the spherical component of aphakic refractive error. This study describes clinical experience with a foldable, injectable, toric IOL.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">Keratometric, refractive and visual data were collected on patients listed for cataract surgery. Toric IOLs were offered where keratometric cylinder was greater than 1.5 dioptres. Small-incision phacoemulsification surgery was performed and the IOL implanted with its long axis along the steep corneal axis. Post-operative refractive data were compared with pre-operative and expected refraction using vector analysis software.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">Results of 22 eyes of 16 consecutive patients implanted with toric IOLs are reported. Two IOLs rotated more than 30 degrees in the first 24 h and were re-dialled surgically. Two further IOLs (9%) rotated more than 30 degrees during follow-up. In 21 of 22 eyes (95%) the refractive astigmatism was reduced, with a mean 73% of planned correction (vector analysis) achieved.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">The toric IOL is a useful surgical tool to reduce the refractive effects of pre-existing corneal astigmatism. Design modification to prevent IOL rotation would make results more predictable.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Leyland</LastName>
<ForeName>M</ForeName>
<Initials>M</Initials>
<AffiliationInfo>
<Affiliation>Hillingdon Hospital NHS Trust, Uxbridge, UK.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Zinicola</LastName>
<ForeName>E</ForeName>
<Initials>E</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Bloom</LastName>
<ForeName>P</ForeName>
<Initials>P</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Lee</LastName>
<ForeName>N</ForeName>
<Initials>N</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D023362">Evaluation Studies</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>England</Country>
<MedlineTA>Eye (Lond)</MedlineTA>
<NlmUniqueID>8703986</NlmUniqueID>
<ISSNLinking>0950-222X</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000369">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D001251">Astigmatism</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000628">therapy</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005500">Follow-Up Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D018918">Phacoemulsification</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011184">Postoperative Period</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011446">Prospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012029">Refraction, Ocular</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2001</Year>
<Month>5</Month>
<Day>8</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2001</Year>
<Month>6</Month>
<Day>2</Day>
<Hour>10</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2001</Year>
<Month>5</Month>
<Day>8</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">11339591</ArticleId>
<ArticleId IdType="doi">10.1038/eye.2001.61</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001D52 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 001D52 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:11339591
   |texte=   Prospective evaluation of a plate haptic toric intraocular lens.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:11339591" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024