A novel technique to release sticking haptic of a single-piece hydrophobic acrylic IOL using irrigation-aspiration probe.

Identifieur interne : 000245 ( PubMed/Curation ); précédent : 000244; suivant : 000246

A novel technique to release sticking haptic of a single-piece hydrophobic acrylic IOL using irrigation-aspiration probe.

Auteurs : Sudarshan Kumar Khokhar ; Neha Midha ; Bharat Patil ; Bhagabat Nayak ; Sriram Simakurthy

Source :

RBID : pubmed:26391168

Abstract

To describe a novel technique to release sticking haptic of a single-piece hydrophobic acrylic intraocular lens (IOL) using irrigation-aspiration (I/A) probe.

DOI: 10.5301/ejo.5000669
PubMed: 26391168

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:26391168

Curation

No country items

Sudarshan Kumar Khokhar
<affiliation>
<nlm:affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</nlm:affiliation>
<wicri:noCountry code="subField">Delhi - India</wicri:noCountry>
</affiliation>
Neha Midha
<affiliation>
<nlm:affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</nlm:affiliation>
<wicri:noCountry code="subField">Delhi - India</wicri:noCountry>
</affiliation>
Bharat Patil
<affiliation>
<nlm:affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</nlm:affiliation>
<wicri:noCountry code="subField">Delhi - India</wicri:noCountry>
</affiliation>
Bhagabat Nayak
<affiliation>
<nlm:affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</nlm:affiliation>
<wicri:noCountry code="subField">Delhi - India</wicri:noCountry>
</affiliation>
Sriram Simakurthy
<affiliation>
<nlm:affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</nlm:affiliation>
<wicri:noCountry code="subField">Delhi - India</wicri:noCountry>
</affiliation>

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">A novel technique to release sticking haptic of a single-piece hydrophobic acrylic IOL using irrigation-aspiration probe.</title>
<author>
<name sortKey="Khokhar, Sudarshan Kumar" sort="Khokhar, Sudarshan Kumar" uniqKey="Khokhar S" first="Sudarshan Kumar" last="Khokhar">Sudarshan Kumar Khokhar</name>
<affiliation>
<nlm:affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</nlm:affiliation>
<wicri:noCountry code="subField">Delhi - India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Midha, Neha" sort="Midha, Neha" uniqKey="Midha N" first="Neha" last="Midha">Neha Midha</name>
<affiliation>
<nlm:affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</nlm:affiliation>
<wicri:noCountry code="subField">Delhi - India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Patil, Bharat" sort="Patil, Bharat" uniqKey="Patil B" first="Bharat" last="Patil">Bharat Patil</name>
<affiliation>
<nlm:affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</nlm:affiliation>
<wicri:noCountry code="subField">Delhi - India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Nayak, Bhagabat" sort="Nayak, Bhagabat" uniqKey="Nayak B" first="Bhagabat" last="Nayak">Bhagabat Nayak</name>
<affiliation>
<nlm:affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</nlm:affiliation>
<wicri:noCountry code="subField">Delhi - India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Simakurthy, Sriram" sort="Simakurthy, Sriram" uniqKey="Simakurthy S" first="Sriram" last="Simakurthy">Sriram Simakurthy</name>
<affiliation>
<nlm:affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</nlm:affiliation>
<wicri:noCountry code="subField">Delhi - India</wicri:noCountry>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2016">2016</date>
<idno type="doi">10.5301/ejo.5000669</idno>
<idno type="RBID">pubmed:26391168</idno>
<idno type="pmid">26391168</idno>
<idno type="wicri:Area/PubMed/Corpus">000245</idno>
<idno type="wicri:Area/PubMed/Curation">000245</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">A novel technique to release sticking haptic of a single-piece hydrophobic acrylic IOL using irrigation-aspiration probe.</title>
<author>
<name sortKey="Khokhar, Sudarshan Kumar" sort="Khokhar, Sudarshan Kumar" uniqKey="Khokhar S" first="Sudarshan Kumar" last="Khokhar">Sudarshan Kumar Khokhar</name>
<affiliation>
<nlm:affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</nlm:affiliation>
<wicri:noCountry code="subField">Delhi - India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Midha, Neha" sort="Midha, Neha" uniqKey="Midha N" first="Neha" last="Midha">Neha Midha</name>
<affiliation>
<nlm:affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</nlm:affiliation>
<wicri:noCountry code="subField">Delhi - India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Patil, Bharat" sort="Patil, Bharat" uniqKey="Patil B" first="Bharat" last="Patil">Bharat Patil</name>
<affiliation>
<nlm:affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</nlm:affiliation>
<wicri:noCountry code="subField">Delhi - India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Nayak, Bhagabat" sort="Nayak, Bhagabat" uniqKey="Nayak B" first="Bhagabat" last="Nayak">Bhagabat Nayak</name>
<affiliation>
<nlm:affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</nlm:affiliation>
<wicri:noCountry code="subField">Delhi - India</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Simakurthy, Sriram" sort="Simakurthy, Sriram" uniqKey="Simakurthy S" first="Sriram" last="Simakurthy">Sriram Simakurthy</name>
<affiliation>
<nlm:affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</nlm:affiliation>
<wicri:noCountry code="subField">Delhi - India</wicri:noCountry>
</affiliation>
</author>
</analytic>
<series>
<title level="j">European journal of ophthalmology</title>
<idno type="eISSN">1724-6016</idno>
<imprint>
<date when="2016" type="published">2016</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To describe a novel technique to release sticking haptic of a single-piece hydrophobic acrylic intraocular lens (IOL) using irrigation-aspiration (I/A) probe.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="In-Data-Review">
<PMID Version="1">26391168</PMID>
<DateCreated>
<Year>2016</Year>
<Month>04</Month>
<Day>16</Day>
</DateCreated>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1724-6016</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>26</Volume>
<Issue>3</Issue>
<PubDate>
<Year>2016</Year>
<Month>Apr</Month>
<Day>12</Day>
</PubDate>
</JournalIssue>
<Title>European journal of ophthalmology</Title>
<ISOAbbreviation>Eur J Ophthalmol</ISOAbbreviation>
</Journal>
<ArticleTitle>A novel technique to release sticking haptic of a single-piece hydrophobic acrylic IOL using irrigation-aspiration probe.</ArticleTitle>
<Pagination>
<MedlinePgn>281-2</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.5301/ejo.5000669</ELocationID>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To describe a novel technique to release sticking haptic of a single-piece hydrophobic acrylic intraocular lens (IOL) using irrigation-aspiration (I/A) probe.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">In our technique, the I/A probe is introduced into the anterior chamber on Visco mode. Using the aspiration port of the I/A probe, the sticking haptic is held at its tip and suction force is built up until occlusion is noted. Then the haptic is nudged towards the center of the IOL along its curve. After the haptic is free from optic, the suction is released.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">Several techniques have been described to release the sticking haptic such as squeezing the haptic at the site where it sticks to the IOL or using Sinskey hook for releasing the adhesion. These techniques require extra manipulation of the IOL by introduction of surgical instruments. In our technique, we used the I/A probe itself for separating the sticky haptic successfully.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">This technique allows separation of sticking haptic without any extra instrumentation, thus reducing intraocular maneuvering and total surgery time.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Khokhar</LastName>
<ForeName>Sudarshan Kumar</ForeName>
<Initials>SK</Initials>
<AffiliationInfo>
<Affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Midha</LastName>
<ForeName>Neha</ForeName>
<Initials>N</Initials>
<AffiliationInfo>
<Affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Patil</LastName>
<ForeName>Bharat</ForeName>
<Initials>B</Initials>
<AffiliationInfo>
<Affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Nayak</LastName>
<ForeName>Bhagabat</ForeName>
<Initials>B</Initials>
<AffiliationInfo>
<Affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Simakurthy</LastName>
<ForeName>Sriram</ForeName>
<Initials>S</Initials>
<AffiliationInfo>
<Affiliation>Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Delhi - India.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2015</Year>
<Month>09</Month>
<Day>14</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>Italy</Country>
<MedlineTA>Eur J Ophthalmol</MedlineTA>
<NlmUniqueID>9110772</NlmUniqueID>
<ISSNLinking>1120-6721</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="ppublish">
<Year>2016</Year>
<Month>4</Month>
<Day>12</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="aheadofprint">
<Year>2015</Year>
<Month>9</Month>
<Day>14</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2015</Year>
<Month>7</Month>
<Day>31</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2015</Year>
<Month>9</Month>
<Day>23</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2015</Year>
<Month>9</Month>
<Day>24</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>9</Month>
<Day>24</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pii">FCBBA2D0-3746-4A22-AC35-E61FFFF85F3A</ArticleId>
<ArticleId IdType="doi">10.5301/ejo.5000669</ArticleId>
<ArticleId IdType="pubmed">26391168</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000245 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000245 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:26391168
   |texte=   A novel technique to release sticking haptic of a single-piece hydrophobic acrylic IOL using irrigation-aspiration probe.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:26391168" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024