Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens.
Identifieur interne : 001217 ( PubMed/Corpus ); précédent : 001216; suivant : 001218Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens.
Auteurs : Mario J. Saldanha ; Larry Benjamin ; Chetan K. PatelSource :
- Journal of cataract and refractive surgery [ 1873-4502 ] ; 2009.
English descriptors
- KwdEn :
- Acrylic Resins, Astigmatism (surgery), Capsulorhexis, Epithelial Cells (pathology), Female, Foreign-Body Migration (etiology), Humans, Image Processing, Computer-Assisted, Lens Capsule, Crystalline (surgery), Lens Implantation, Intraocular, Lenses, Intraocular, Male, Phacoemulsification, Postoperative Complications, Prospective Studies, Rotation.
- MESH :
- chemical : Acrylic Resins.
- etiology : Foreign-Body Migration.
- pathology : Epithelial Cells.
- surgery : Astigmatism, Lens Capsule, Crystalline.
- Capsulorhexis, Female, Humans, Image Processing, Computer-Assisted, Lens Implantation, Intraocular, Lenses, Intraocular, Male, Phacoemulsification, Postoperative Complications, Prospective Studies, Rotation.
Abstract
To assess the rotational stability of the AcrySof MA60BM acrylic intraocular lens (IOL) with and without aspiration of residual lens epithelial cells (LECs).
DOI: 10.1016/j.jcrs.2009.05.024
PubMed: 19781471
Links to Exploration step
pubmed:19781471Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens.</title>
<author><name sortKey="Saldanha, Mario J" sort="Saldanha, Mario J" uniqKey="Saldanha M" first="Mario J" last="Saldanha">Mario J. Saldanha</name>
<affiliation><nlm:affiliation>Oxford Eye Hospital, UK.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Benjamin, Larry" sort="Benjamin, Larry" uniqKey="Benjamin L" first="Larry" last="Benjamin">Larry Benjamin</name>
</author>
<author><name sortKey="Patel, Chetan K" sort="Patel, Chetan K" uniqKey="Patel C" first="Chetan K" last="Patel">Chetan K. Patel</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2009">2009</date>
<idno type="doi">10.1016/j.jcrs.2009.05.024</idno>
<idno type="RBID">pubmed:19781471</idno>
<idno type="pmid">19781471</idno>
<idno type="wicri:Area/PubMed/Corpus">001217</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens.</title>
<author><name sortKey="Saldanha, Mario J" sort="Saldanha, Mario J" uniqKey="Saldanha M" first="Mario J" last="Saldanha">Mario J. Saldanha</name>
<affiliation><nlm:affiliation>Oxford Eye Hospital, UK.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Benjamin, Larry" sort="Benjamin, Larry" uniqKey="Benjamin L" first="Larry" last="Benjamin">Larry Benjamin</name>
</author>
<author><name sortKey="Patel, Chetan K" sort="Patel, Chetan K" uniqKey="Patel C" first="Chetan K" last="Patel">Chetan K. Patel</name>
</author>
</analytic>
<series><title level="j">Journal of cataract and refractive surgery</title>
<idno type="eISSN">1873-4502</idno>
<imprint><date when="2009" type="published">2009</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Acrylic Resins</term>
<term>Astigmatism (surgery)</term>
<term>Capsulorhexis</term>
<term>Epithelial Cells (pathology)</term>
<term>Female</term>
<term>Foreign-Body Migration (etiology)</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted</term>
<term>Lens Capsule, Crystalline (surgery)</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Phacoemulsification</term>
<term>Postoperative Complications</term>
<term>Prospective Studies</term>
<term>Rotation</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Acrylic Resins</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en"><term>Foreign-Body Migration</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en"><term>Epithelial Cells</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en"><term>Astigmatism</term>
<term>Lens Capsule, Crystalline</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Capsulorhexis</term>
<term>Female</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Phacoemulsification</term>
<term>Postoperative Complications</term>
<term>Prospective Studies</term>
<term>Rotation</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">To assess the rotational stability of the AcrySof MA60BM acrylic intraocular lens (IOL) with and without aspiration of residual lens epithelial cells (LECs).</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">19781471</PMID>
<DateCreated><Year>2009</Year>
<Month>09</Month>
<Day>28</Day>
</DateCreated>
<DateCompleted><Year>2009</Year>
<Month>10</Month>
<Day>30</Day>
</DateCompleted>
<Article PubModel="Print"><Journal><ISSN IssnType="Electronic">1873-4502</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>35</Volume>
<Issue>10</Issue>
<PubDate><Year>2009</Year>
<Month>Oct</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens.</ArticleTitle>
<Pagination><MedlinePgn>1751-5</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/j.jcrs.2009.05.024</ELocationID>
<Abstract><AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To assess the rotational stability of the AcrySof MA60BM acrylic intraocular lens (IOL) with and without aspiration of residual lens epithelial cells (LECs).</AbstractText>
<AbstractText Label="SETTING" NlmCategory="METHODS">Stoke Mandeville Hospital, Aylesbury, United Kingdom.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">Routine phacoemulsification was performed with (Group A) or without (Group B) aspiration of residual LECs (random allocation). The baseline position of the IOL was determined from a video frame acquired at the conclusion of surgery. Postoperative IOL position was documented using digital retroillumination images at 2 weeks and 3 months. Early IOL rotation (surgery to 2 weeks postoperatively) was graded as mild (<10 degrees), moderate (10 to 30 degrees), or severe (>30 degrees) by semiobjective comparison of the images. Late IOL rotation (2 weeks to 3 months) was measured more precisely using purpose-designed software.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">Group A had incomplete aspiration of residual LECs. The only between-group demographic difference was significantly more men in Group A than in Group B (P<.05). There were no cases of severe early IOL rotation. Mild and moderate early rotation occurred in 91.5% of eyes and 8.5% of eyes, respectively. The mean late rotation was 0.03 degrees +/- 3.06 (SD) (range 7.8 to -8.7 degrees). Aspiration of residual LECs made no statistical difference in early or late rotation (P>.05). Between 2 weeks and 3 months, counterclockwise rotation occurred in 50% of all cases.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Postoperative rotation of the loop-haptic IOL was stable; LEC clearance did not adversely affect performance. The tendency toward counterclockwise rotation would not preclude good performance of a toric model of the IOL.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Saldanha</LastName>
<ForeName>Mario J</ForeName>
<Initials>MJ</Initials>
<AffiliationInfo><Affiliation>Oxford Eye Hospital, UK.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Benjamin</LastName>
<ForeName>Larry</ForeName>
<Initials>L</Initials>
</Author>
<Author ValidYN="Y"><LastName>Patel</LastName>
<ForeName>Chetan K</ForeName>
<Initials>CK</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D016449">Randomized Controlled Trial</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D000180">Acrylic Resins</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="N" UI="D000180">Acrylic Resins</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D001251">Astigmatism</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D019923">Capsulorhexis</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D004847">Epithelial Cells</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000473">pathology</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D005548">Foreign-Body Migration</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000209">etiology</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D007091">Image Processing, Computer-Assisted</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D007903">Lens Capsule, Crystalline</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D018918">Phacoemulsification</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D011183">Postoperative Complications</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011446">Prospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D012399">Rotation</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="received"><Year>2009</Year>
<Month>3</Month>
<Day>5</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="revised"><Year>2009</Year>
<Month>5</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted"><Year>2009</Year>
<Month>5</Month>
<Day>5</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2009</Year>
<Month>9</Month>
<Day>29</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2009</Year>
<Month>9</Month>
<Day>29</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2009</Year>
<Month>10</Month>
<Day>31</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pii">S0886-3350(09)00601-4</ArticleId>
<ArticleId IdType="doi">10.1016/j.jcrs.2009.05.024</ArticleId>
<ArticleId IdType="pubmed">19781471</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001217 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001217 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:19781471 |texte= Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:19781471" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |