Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Depth compression based on mis-scaling of binocular disparity may contribute to angular expansion in perceived optical slant

Identifieur interne : 001488 ( Pmc/Corpus ); précédent : 001487; suivant : 001489

Depth compression based on mis-scaling of binocular disparity may contribute to angular expansion in perceived optical slant

Auteurs : Zhi Li ; Frank H. Durgin

Source :

RBID : PMC:3791958

Abstract

Three studies, involving a total of 145 observers examined quantitative theories of the overestimation of perceived optical slant. The first two studies investigated the depth/width anisotropies on positive and negative slant in both pitch and yaw at 2 and 8 m using calibrated immersive virtual environments. Observers made judgments of the relative lengths of extents that were frontal with those that were in depth. The physical aspect ratio that was perceived as 1:1 was determined for each slant. The observed anisotropies can be modeled by assuming overestimation in perceived slant. Three one-parameter slant perception models (angular expansion, affine depth compression caused by mis-scaling of binocular disparity, and intrinsic bias) were compared. The angular expansion and the affine depth compression models provided significantly better fits to the aspect ratio data than the intrinsic bias model did. The affine model required depth compression at the 2 m distance; however, that was much more than the depth compression measured directly in the third study using the same apparatus. The present results suggest that depth compression based on mis-scaling of binocular disparity may contribute to slant overestimation, especially as viewing distance increases, but also suggest that a functional rather than mechanistic account may be more appropriate for explaining biases in perceived slant in near space.


Url:
DOI: 10.1167/13.12.3
PubMed: 24097046
PubMed Central: 3791958

Links to Exploration step

PMC:3791958***** Acces problem to record *****\

Le document en format XML


Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001488 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 001488 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:3791958
   |texte=   Depth compression based on mis-scaling of binocular disparity may contribute to angular expansion in perceived optical slant
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:24097046" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024