Aim

To report the clinical outcome of a surgical technique for insertion of the silicone tube of a Baerveldt glaucoma implant (BGI) in the posterior chamber sulcus.

Methods

Non‐comparative, interventional case series. Eight eyes of eight patients, with a follow‐up of at least 18 months, who underwent insertion of a BGI with the silicone tube placed in the posterior chamber sulcus between 1998 and 2005 were included. Control of intraocular pressure (IOP), number of pressure‐lowering medications, visual acuity and surgical complications were recorded.

Results

Eight eyes of eight patients (mean (range) age 76.4 (62–94) years) were included in the study. The IOP was reduced from a preoperative mean (SD) of 28.2 (14.4) to 12.6 (5.8) mm Hg at 18 months. The mean (SD) number of preoperative medications for IOP control was reduced from 2.8 (1.5) to 1.3 (1.5) medications in the same period. No complications were observed during surgery or follow‐up.

Conclusion

Placement of the silicone tube in the posterior chamber sulcus is a safe and effective alternative technique for IOP control in patients with pseudophakia. Sulcus placement may reduce the likelihood of corneal endothelial loss and avoid the need for pars‐plana vitrectomy and posterior segment tube insertion in complicated eyes.


Url:
DOI: 10.1136/bjo.2006.107839
PubMed: 17301121
PubMed Central: 1955614

Links to Exploration step

PMC:1955614***** Acces problem to record *****\

Le document en format XML


Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000946 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 000946 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:1955614
   |texte=   Baerveldt glaucoma implant insertion in the posterior chamber sulcus
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:17301121" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024