Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Training for laparoscopic Nissen fundoplication with a newly designed model: a replacement for animal tissue models?

Identifieur interne : 000890 ( Pmc/Corpus ); précédent : 000889; suivant : 000891

Training for laparoscopic Nissen fundoplication with a newly designed model: a replacement for animal tissue models?

Auteurs : Sanne M. B. I. Botden ; Lorna Christie ; Richard Goossens ; Jack J. Jakimowicz

Source :

RBID : PMC:2982997

Abstract

Background

To bridge the early learning curve for laparoscopic Nissen fundoplication from the clinical setting to a safe environment, training models can be used. This study aimed to develop a reusable, low-cost model to be used for training in laparoscopic Nissen fundoplication procedure as an alternative to the use of animal tissue models.

Methods

From artificial organs and tissue, an anatomic model of the human upper abdomen was developed for training in performing laparoscopic Nissen fundoplication. The 20 participants and tutors in the European Association for Endoscopic Surgery (EAES) upper gastrointestinal surgery course completed four complementary tasks of laparoscopic Nissen fundoplication with the artificial model, then compared the realism, haptic feedback, and training properties of the model with those of animal tissue models.

Results

The main difference between the two training models was seen in the properties of the stomach. The wrapping of the stomach in the artificial model was rated significantly lower than that in the animal tissue model (mean, 3.6 vs. 4.2; p = 0.010). The main criticism of the stomach of the artificial model was that it was too rigid for making a proper wrap. The suturing of the stomach wall, however, was regarded as fairly realistic (mean, 3.6). The crura on the artificial model were rated better (mean, 4.3) than those on the animal tissue (mean, 4.0), although the difference was not significant. The participants regarded the model as a good to excellent (mean, 4.3) training tool.

Conclusion

The newly developed model is regarded as a good tool for training in laparoscopic Nissen fundoplication procedure. It is cheaper, more durable, and more readily available for training and can therefore be used in every training center. The stomach of this model, however, still needs improvement because it is too rigid for making the wrap.


Url:
DOI: 10.1007/s00464-010-1104-0
PubMed: 20526629
PubMed Central: 2982997

Links to Exploration step

PMC:2982997***** Acces problem to record *****\

Le document en format XML


Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000890 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 000890 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:2982997
   |texte=   Training for laparoscopic Nissen fundoplication with a newly designed model: a replacement for animal tissue models?
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:20526629" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024