OpenHELP (Heidelberg laparoscopy phantom): development of an open-source surgical evaluation and training tool

Identifieur interne : 000882 ( Pmc/Corpus ); précédent : 000881; suivant : 000883

OpenHELP (Heidelberg laparoscopy phantom): development of an open-source surgical evaluation and training tool

Auteurs : H. G. Kenngott ; J. J. Wünscher ; M. Wagner ; A. Preukschas ; A. L. Wekerle ; P. Neher ; S. Suwelack ; S. Speidel ; F. Nickel ; D. Oladokun ; L. Maier-Hein ; R. Dillmann ; H. P. Meinzer ; B. P. Müller-Stich

Source :

RBID : PMC:4607709

Abstract

Background

Apart from animal testing and clinical trials, surgical research and laparoscopic training mainly rely on phantoms. The aim of this project was to design a phantom with realistic anatomy and haptic characteristics, modular design and easy reproducibility. The phantom was named open-source Heidelberg laparoscopic phantom (OpenHELP) and serves as an open-source platform.

Methods

The phantom was based on an anonymized CT scan of a male patient. The anatomical structures were segmented to obtain digital three-dimensional models of the torso and the organs. The digital models were materialized via rapid prototyping. One flexible, using an elastic abdominal wall, and one rigid method, using a plastic shell, to simulate pneumoperitoneum were developed. Artificial organ production was carried out sequentially starting from raw gypsum models to silicone molds to final silicone casts. The reproduction accuracy was exemplarily evaluated for ten silicone rectum models by comparing the digital 3D surface of the original rectum with CT scan by calculating the root mean square error of surface variations. Haptic realism was also evaluated to find the most realistic silicone compositions on a visual analog scale (VAS, 0–10).

Results

The rigid and durable plastic torso and soft silicone organs of the abdominal cavity were successfully produced. A simulation of pneumoperitoneum could be created successfully by both methods. The reproduction accuracy of ten silicone rectum models showed an average root mean square error of 2.26 (0–11.48) mm. Haptic realism revealed an average value on a VAS of 7.25 (5.2–9.6) for the most realistic rectum.

Conclusion

The OpenHELP phantom proved to be feasible and accurate. The phantom was consecutively applied frequently in the field of computer-assisted surgery at our institutions and is accessible as an open-source project at www.open-cas.org for the academic community.


Url:
DOI: 10.1007/s00464-015-4094-0
PubMed: 25673345
PubMed Central: 4607709

Links to Exploration step

PMC:4607709***** Acces problem to record *****\

Le document en format XML


Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000882 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 000882 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:4607709
   |texte=   OpenHELP (Heidelberg laparoscopy phantom): development of an open-source surgical evaluation and training tool
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:25673345" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024