Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

A fast and stable vascular deformation scheme for interventional surgery training system

Identifieur interne : 000773 ( Pmc/Corpus ); précédent : 000772; suivant : 000774

A fast and stable vascular deformation scheme for interventional surgery training system

Auteurs : Xiufen Ye ; Jianguo Zhang ; Peng Li ; Tian Wang ; Shuxiang Guo

Source :

RBID : PMC:4822255

Abstract

Background

The emergence and development of robot assistant interventional vascular surgery technologies have benefited many patients with cardiovascular or cerebrovascular diseases. Due to the absence of effective training measures, these new advanced technologies have not been fully utilized and only few experienced surgeons can perform such complicated surgeries so far. In order to solve such problems, virtual reality based vascular interventional surgery training system, a promising way to train young surgeons or assist experienced surgeons to perform surgery, has been widely studied.

Methods

In this paper, we mainly conduct a thorough study on both reliable deformation and high real-time performance of an interactive surgery training system. An efficient hybrid geometric blood vessel model which handles the collision detection query and vascular deformation calculation separately is employed to enhance the real-time performance of our surgery training system. In addition, a position-based dynamic approach with volume conservation constraint is used to improve the vascular deformation result. Finally, a hash table based spatial adaptive acceleration algorithm which makes the training system much more efficient and reliable is described.

Results

Several necessary experiments are conducted to validate the vascular deformation scheme presented in this paper. From the results we can see that the position-based dynamic modeling method with volume conservation constraint can prevent the vascular deformation from the issue of penetration. In addition, the deformation calculation with spatial acceleration algorithm has enhanced the real-time performance significantly.

Conclusion

The corresponding experimental results indicate that both the hybrid geometric blood vessel model and the hash table based spatial adaptive acceleration algorithm can enhance the performance of our surgery training system greatly without losing the deformation accuracy.


Url:
DOI: 10.1186/s12938-016-0148-3
PubMed: 27048290
PubMed Central: 4822255

Links to Exploration step

PMC:4822255***** Acces problem to record *****\

Le document en format XML


Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000773 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 000773 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:4822255
   |texte=   A fast and stable vascular deformation scheme for interventional surgery training system
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:27048290" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024