Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Dependence of the Impact Response of Polyvinylidene Fluoride Sensors on Their Supporting Materials' Elasticity

Identifieur interne : 001329 ( Pmc/Checkpoint ); précédent : 001328; suivant : 001330

Dependence of the Impact Response of Polyvinylidene Fluoride Sensors on Their Supporting Materials' Elasticity

Auteurs : Yunfang Jia ; Xinjuan Chen ; Qingshan Ni ; Longhua Li ; Cheng Ju

Source :

RBID : PMC:3758616

Abstract

Polyvinylidene fluoride (PVDF) is popular sensing material because of its unique piezoelectric characteristics. In this work an impact sensor was prepared from a sandwiched structure PVDF film, and the related detection circuits were presented. The dependence of the PVDF sensors' response on the elasticity of the supporting materials was examined and discussed. Here two response indexes were discussed, which were the peak-to-peak voltage (Vpp) and the recovery time. Firstly, falling impact experiments were executed on desk-supported PVDF sensors (100 μm PVDF film) using free falls of different weights from different heights. Then the same shock experiments were repeated on the same sensor, but changing the backstops to a sponge and rubber, respectively. On the desk, the values of Vpp were bigger than when the other two backstops were used; but the changes of the impact energy could not be reflected by the PVDF sensor when it was supported by a hard material. It was found that the biggest sensitivity of the voltage response (about 96.62 V/J) was obtained by the sponge-supported sensor; for the same sensor, when it was supported by rubber, the slope was 82.26 V/J. Moreover, the recovery time for the desk-supported sensor was almost constant, varying from 0.15 to 0.18 s, while for the same sensor supported by sponge or rubber, its recovery time changed with the shifting of the impact energy in the range of 0.02∼0.36 s, but no pattern could be found in the recovery-time characteristics.


Url:
DOI: 10.3390/s130708669
PubMed: 23881132
PubMed Central: 3758616


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:3758616

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Dependence of the Impact Response of Polyvinylidene Fluoride Sensors on Their Supporting Materials' Elasticity</title>
<author>
<name sortKey="Jia, Yunfang" sort="Jia, Yunfang" uniqKey="Jia Y" first="Yunfang" last="Jia">Yunfang Jia</name>
</author>
<author>
<name sortKey="Chen, Xinjuan" sort="Chen, Xinjuan" uniqKey="Chen X" first="Xinjuan" last="Chen">Xinjuan Chen</name>
</author>
<author>
<name sortKey="Ni, Qingshan" sort="Ni, Qingshan" uniqKey="Ni Q" first="Qingshan" last="Ni">Qingshan Ni</name>
</author>
<author>
<name sortKey="Li, Longhua" sort="Li, Longhua" uniqKey="Li L" first="Longhua" last="Li">Longhua Li</name>
</author>
<author>
<name sortKey="Ju, Cheng" sort="Ju, Cheng" uniqKey="Ju C" first="Cheng" last="Ju">Cheng Ju</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">23881132</idno>
<idno type="pmc">3758616</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3758616</idno>
<idno type="RBID">PMC:3758616</idno>
<idno type="doi">10.3390/s130708669</idno>
<date when="2013">2013</date>
<idno type="wicri:Area/Pmc/Corpus">002471</idno>
<idno type="wicri:Area/Pmc/Curation">002471</idno>
<idno type="wicri:Area/Pmc/Checkpoint">001329</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Dependence of the Impact Response of Polyvinylidene Fluoride Sensors on Their Supporting Materials' Elasticity</title>
<author>
<name sortKey="Jia, Yunfang" sort="Jia, Yunfang" uniqKey="Jia Y" first="Yunfang" last="Jia">Yunfang Jia</name>
</author>
<author>
<name sortKey="Chen, Xinjuan" sort="Chen, Xinjuan" uniqKey="Chen X" first="Xinjuan" last="Chen">Xinjuan Chen</name>
</author>
<author>
<name sortKey="Ni, Qingshan" sort="Ni, Qingshan" uniqKey="Ni Q" first="Qingshan" last="Ni">Qingshan Ni</name>
</author>
<author>
<name sortKey="Li, Longhua" sort="Li, Longhua" uniqKey="Li L" first="Longhua" last="Li">Longhua Li</name>
</author>
<author>
<name sortKey="Ju, Cheng" sort="Ju, Cheng" uniqKey="Ju C" first="Cheng" last="Ju">Cheng Ju</name>
</author>
</analytic>
<series>
<title level="j">Sensors (Basel, Switzerland)</title>
<idno type="eISSN">1424-8220</idno>
<imprint>
<date when="2013">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>Polyvinylidene fluoride (PVDF) is popular sensing material because of its unique piezoelectric characteristics. In this work an impact sensor was prepared from a sandwiched structure PVDF film, and the related detection circuits were presented. The dependence of the PVDF sensors' response on the elasticity of the supporting materials was examined and discussed. Here two response indexes were discussed, which were the peak-to-peak voltage (V
<sub>pp</sub>
) and the recovery time. Firstly, falling impact experiments were executed on desk-supported PVDF sensors (100 μm PVDF film) using free falls of different weights from different heights. Then the same shock experiments were repeated on the same sensor, but changing the backstops to a sponge and rubber, respectively. On the desk, the values of V
<sub>pp</sub>
were bigger than when the other two backstops were used; but the changes of the impact energy could not be reflected by the PVDF sensor when it was supported by a hard material. It was found that the biggest sensitivity of the voltage response (about 96.62 V/J) was obtained by the sponge-supported sensor; for the same sensor, when it was supported by rubber, the slope was 82.26 V/J. Moreover, the recovery time for the desk-supported sensor was almost constant, varying from 0.15 to 0.18 s, while for the same sensor supported by sponge or rubber, its recovery time changed with the shifting of the impact energy in the range of 0.02∼0.36 s, but no pattern could be found in the recovery-time characteristics.</p>
</div>
</front>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct>
<analytic>
<author>
<name sortKey="Kawai, H" uniqKey="Kawai H">H. Kawai</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Lima, J A P" uniqKey="Lima J">J.A.P. Lima</name>
</author>
<author>
<name sortKey="Marin, E" uniqKey="Marin E">E. Marin</name>
</author>
<author>
<name sortKey="Da Silva, M G" uniqKey="Da Silva M">M.G. da Silva</name>
</author>
<author>
<name sortKey="Sthel, M S" uniqKey="Sthel M">M.S. Sthel</name>
</author>
<author>
<name sortKey="Cardoso, S L" uniqKey="Cardoso S">S.L. Cardoso</name>
</author>
<author>
<name sortKey="Vargas, H" uniqKey="Vargas H">H. Vargas</name>
</author>
<author>
<name sortKey="Miranda, L C M" uniqKey="Miranda L">L.C.M. Miranda</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kepler, R G" uniqKey="Kepler R">R.G. Kepler</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Fukada, E" uniqKey="Fukada E">E. Fukada</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Huh, Y H" uniqKey="Huh Y">Y.-H. Huh</name>
</author>
<author>
<name sortKey="Kim, J I" uniqKey="Kim J">J.I. Kim</name>
</author>
<author>
<name sortKey="Lee, J H" uniqKey="Lee J">J.H. Lee</name>
</author>
<author>
<name sortKey="Hong, S G" uniqKey="Hong S">S.G. Hong</name>
</author>
<author>
<name sortKey="Park, J H" uniqKey="Park J">J.H. Park</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Xu, J" uniqKey="Xu J">J. Xu</name>
</author>
<author>
<name sortKey="Dapinoa, M J" uniqKey="Dapinoa M">M.J. Dapinoa</name>
</author>
<author>
<name sortKey="Gallego Perez, D" uniqKey="Gallego Perez D">D. Gallego Perez</name>
</author>
<author>
<name sortKey="Hansford, D" uniqKey="Hansford D">D. Hansford</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Toda, M" uniqKey="Toda M">M. Toda</name>
</author>
<author>
<name sortKey="Dahl, J" uniqKey="Dahl J">J. Dahl</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Rathod, V T" uniqKey="Rathod V">V.T. Rathod</name>
</author>
<author>
<name sortKey="Mahapatra, D R" uniqKey="Mahapatra D">D.R. Mahapatra</name>
</author>
<author>
<name sortKey="Jain, A" uniqKey="Jain A">A. Jain</name>
</author>
<author>
<name sortKey="Gayathri, A" uniqKey="Gayathri A">A. Gayathri</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Seminara, L" uniqKey="Seminara L">L. Seminara</name>
</author>
<author>
<name sortKey="Capurro, M" uniqKey="Capurro M">M. Capurro</name>
</author>
<author>
<name sortKey="Cirillo, P" uniqKey="Cirillo P">P. Cirillo</name>
</author>
<author>
<name sortKey="Cannata, G" uniqKey="Cannata G">G. Cannata</name>
</author>
<author>
<name sortKey="Valle, M" uniqKey="Valle M">M. Valle</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Dahiya, R S" uniqKey="Dahiya R">R.S. Dahiya</name>
</author>
<author>
<name sortKey="Valle, M" uniqKey="Valle M">M. Valle</name>
</author>
<author>
<name sortKey="Metta, G" uniqKey="Metta G">G. Metta</name>
</author>
<author>
<name sortKey="Lorenzelli, L" uniqKey="Lorenzelli L">L. Lorenzelli</name>
</author>
<author>
<name sortKey="Adami, A" uniqKey="Adami A">A. Adami</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Tsuchimi, D" uniqKey="Tsuchimi D">D. Tsuchimi</name>
</author>
<author>
<name sortKey="Okuyama, T" uniqKey="Okuyama T">T. Okuyama</name>
</author>
<author>
<name sortKey="Tanaka, M" uniqKey="Tanaka M">M. Tanaka</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Matsunaga, N" uniqKey="Matsunaga N">N. Matsunaga</name>
</author>
<author>
<name sortKey="Zengin, A T" uniqKey="Zengin A">A.T. Zengin</name>
</author>
<author>
<name sortKey="Kawaji, S" uniqKey="Kawaji S">S. Kawaji</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Gao, G" uniqKey="Gao G">G. Gao</name>
</author>
<author>
<name sortKey="Wang, Z" uniqKey="Wang Z">Z. Wang</name>
</author>
<author>
<name sortKey="Gao, R" uniqKey="Gao R">R. Gao</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Kimoto, A" uniqKey="Kimoto A">A. Kimoto</name>
</author>
<author>
<name sortKey="Sugitani, N" uniqKey="Sugitani N">N. Sugitani</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Chuang, C H" uniqKey="Chuang C">C.H. Chuang</name>
</author>
<author>
<name sortKey="Liou, Y R" uniqKey="Liou Y">Y.R. Liou</name>
</author>
<author>
<name sortKey="Chen, C W" uniqKey="Chen C">C.W. Chen</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Bauer, F" uniqKey="Bauer F">F. Bauer</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Zhang, A" uniqKey="Zhang A">A. Zhang</name>
</author>
<author>
<name sortKey="Tang, Z" uniqKey="Tang Z">Z. Tang</name>
</author>
<author>
<name sortKey="Zheng, H" uniqKey="Zheng H">H. Zheng</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Bauer, F" uniqKey="Bauer F">F. Bauer</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Dargahi, J" uniqKey="Dargahi J">J. Dargahi</name>
</author>
<author>
<name sortKey="Parameswaran, M" uniqKey="Parameswaran M">M. Parameswaran</name>
</author>
<author>
<name sortKey="Payandeh, S" uniqKey="Payandeh S">S. Payandeh</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Tavakkoli, J" uniqKey="Tavakkoli J">J. Tavakkoli</name>
</author>
<author>
<name sortKey="Birer, A" uniqKey="Birer A">A. Birer</name>
</author>
<author>
<name sortKey="Cathignol, D" uniqKey="Cathignol D">D. Cathignol</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Sharma, T" uniqKey="Sharma T">T. Sharma</name>
</author>
<author>
<name sortKey="Je, S" uniqKey="Je S">S. Je</name>
</author>
<author>
<name sortKey="Gill, B" uniqKey="Gill B">B. Gill</name>
</author>
<author>
<name sortKey="Zhang, X J" uniqKey="Zhang X">X.J. Zhang</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Chiu, Y Y" uniqKey="Chiu Y">Y.Y. Chiu</name>
</author>
<author>
<name sortKey="Lin, W Y" uniqKey="Lin W">W.Y. Lin</name>
</author>
<author>
<name sortKey="Wang, H Y" uniqKey="Wang H">H.Y. Wang</name>
</author>
<author>
<name sortKey="Huang, S B" uniqKey="Huang S">S.B. Huang</name>
</author>
<author>
<name sortKey="Wu, M H" uniqKey="Wu M">M.H. Wu</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Rajala, S" uniqKey="Rajala S">S. Rajala</name>
</author>
<author>
<name sortKey="Lekkala, J" uniqKey="Lekkala J">J. Lekkala</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Ngalamou, L" uniqKey="Ngalamou L">L. Ngalamou</name>
</author>
<author>
<name sortKey="Noury, N" uniqKey="Noury N">N. Noury</name>
</author>
<author>
<name sortKey="Chamberod, E" uniqKey="Chamberod E">E. Chamberod</name>
</author>
<author>
<name sortKey="Benech, P" uniqKey="Benech P">P. Benech</name>
</author>
</analytic>
</biblStruct>
</listBibl>
</div1>
</back>
</TEI>
<pmc article-type="research-article">
<pmc-dir>properties open_access</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Sensors (Basel)</journal-id>
<journal-id journal-id-type="iso-abbrev">Sensors (Basel)</journal-id>
<journal-title-group>
<journal-title>Sensors (Basel, Switzerland)</journal-title>
</journal-title-group>
<issn pub-type="epub">1424-8220</issn>
<publisher>
<publisher-name>MDPI</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">23881132</article-id>
<article-id pub-id-type="pmc">3758616</article-id>
<article-id pub-id-type="doi">10.3390/s130708669</article-id>
<article-id pub-id-type="publisher-id">sensors-13-08669</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Dependence of the Impact Response of Polyvinylidene Fluoride Sensors on Their Supporting Materials' Elasticity</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Jia</surname>
<given-names>Yunfang</given-names>
</name>
<xref rid="c1-sensors-13-08669" ref-type="corresp">
<sup>*</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Chen</surname>
<given-names>Xinjuan</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Ni</surname>
<given-names>Qingshan</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Li</surname>
<given-names>Longhua</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Ju</surname>
<given-names>Cheng</given-names>
</name>
</contrib>
<aff id="af1-sensors-13-08669">The College of Information Technical Science, Nankai University, Tianjin 300071, China; E-Mails:
<email>chenxin_juan@126.com</email>
(X.C.);
<email>nqsnankai@163.com</email>
(Q.N.);
<email>longhuasmile@163.com</email>
(L.L.);
<email>15114574349@163.com</email>
(C.J.)</aff>
</contrib-group>
<author-notes>
<corresp id="c1-sensors-13-08669">
<label>*</label>
Author to whom correspondence should be addressed; E-Mail:
<email>jiayf@nankai.edu.cn</email>
; Tel.: +86-22-2350-1565.</corresp>
</author-notes>
<pub-date pub-type="collection">
<month>7</month>
<year>2013</year>
</pub-date>
<pub-date pub-type="epub">
<day>05</day>
<month>7</month>
<year>2013</year>
</pub-date>
<volume>13</volume>
<issue>7</issue>
<fpage>8669</fpage>
<lpage>8678</lpage>
<history>
<date date-type="received">
<day>13</day>
<month>4</month>
<year>2013</year>
</date>
<date date-type="rev-recd">
<day>08</day>
<month>5</month>
<year>2013</year>
</date>
<date date-type="accepted">
<day>23</day>
<month>6</month>
<year>2013</year>
</date>
</history>
<permissions>
<copyright-statement>© 2013 by the authors; licensee MDPI, Basel, Switzerland.</copyright-statement>
<copyright-year>2013</copyright-year>
<license>
<license-p>
<pmc-comment>CREATIVE COMMONS</pmc-comment>
This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (
<ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/3.0/">http://creativecommons.org/licenses/by/3.0/</ext-link>
).</license-p>
</license>
</permissions>
<abstract>
<p>Polyvinylidene fluoride (PVDF) is popular sensing material because of its unique piezoelectric characteristics. In this work an impact sensor was prepared from a sandwiched structure PVDF film, and the related detection circuits were presented. The dependence of the PVDF sensors' response on the elasticity of the supporting materials was examined and discussed. Here two response indexes were discussed, which were the peak-to-peak voltage (V
<sub>pp</sub>
) and the recovery time. Firstly, falling impact experiments were executed on desk-supported PVDF sensors (100 μm PVDF film) using free falls of different weights from different heights. Then the same shock experiments were repeated on the same sensor, but changing the backstops to a sponge and rubber, respectively. On the desk, the values of V
<sub>pp</sub>
were bigger than when the other two backstops were used; but the changes of the impact energy could not be reflected by the PVDF sensor when it was supported by a hard material. It was found that the biggest sensitivity of the voltage response (about 96.62 V/J) was obtained by the sponge-supported sensor; for the same sensor, when it was supported by rubber, the slope was 82.26 V/J. Moreover, the recovery time for the desk-supported sensor was almost constant, varying from 0.15 to 0.18 s, while for the same sensor supported by sponge or rubber, its recovery time changed with the shifting of the impact energy in the range of 0.02∼0.36 s, but no pattern could be found in the recovery-time characteristics.</p>
</abstract>
<kwd-group>
<kwd>PVDF</kwd>
<kwd>piezoelectric polymer</kwd>
<kwd>impact response</kwd>
<kwd>peak-to-peak voltage</kwd>
<kwd>recovery time</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec>
<label>1.</label>
<title>Introduction</title>
<p>Polyvinylidene fluoride (PVDF) is reported to possess the properties of piezoelectricity, pyroelectricity and ferroelectricity [
<xref rid="b1-sensors-13-08669" ref-type="bibr">1</xref>
<xref rid="b3-sensors-13-08669" ref-type="bibr">3</xref>
]. Because of the PVDF film features of high sensitivity, wide frequency response, flexibility, cost effectiveness, ease of fabrication and light weight, it has been a popular sensing material because of its unique piezoelectric characteristics, though many other kinds of piezoelectric polymers have been proposed [
<xref rid="b4-sensors-13-08669" ref-type="bibr">4</xref>
].</p>
<p>For examples, deformation-caused piezoelectric sensing was induced by adhering PVDF sensors onto the surface of a wind turbine blade, allowing the damage to the blade to be monitored [
<xref rid="b5-sensors-13-08669" ref-type="bibr">5</xref>
]. A novel acoustic sensor was developed using microsized PVDF pillars which were arrayed and sandwiched between two electrodes [
<xref rid="b6-sensors-13-08669" ref-type="bibr">6</xref>
]. In the field of ultrasonic range sensors, both the transmitter and receiver could be built from separate curved PVDF transducers or a single one [
<xref rid="b7-sensors-13-08669" ref-type="bibr">7</xref>
], and the ultrasonic properties of the large-area PVDF film were characterized and compared with PZT for the purpose of evaluating its performance in ultrasonic sensing [
<xref rid="b8-sensors-13-08669" ref-type="bibr">8</xref>
]. In robotic applications, PVDF touch sensors were good candidates [
<xref rid="b9-sensors-13-08669" ref-type="bibr">9</xref>
], a novel touching sensor named Piezoelectric Oxide Semiconductor FET (POSFET) was proposed [
<xref rid="b10-sensors-13-08669" ref-type="bibr">10</xref>
] and applied in human skin condition monitoring [
<xref rid="b11-sensors-13-08669" ref-type="bibr">11</xref>
]. Based on the traditional PVDF touch sensor, a multilayered PVDF film was adopted to construct pain sensors [
<xref rid="b12-sensors-13-08669" ref-type="bibr">12</xref>
], and identification of materials could be performed by monitoring the peak of PVDF sensors' output signal after touching target objects [
<xref rid="b13-sensors-13-08669" ref-type="bibr">13</xref>
,
<xref rid="b14-sensors-13-08669" ref-type="bibr">14</xref>
], and the detection of incident slippage and static friction was executed by PVDF tactile sensors with structured electrodes [
<xref rid="b15-sensors-13-08669" ref-type="bibr">15</xref>
]. When compared with fragile ceramic piezoelectric materials, the native tenacity and flexibility of PVDF piezoelectric film make it an ideal candidate for shock sensors [
<xref rid="b16-sensors-13-08669" ref-type="bibr">16</xref>
]. Voltage signals is response to impacts could be examined in a collision [
<xref rid="b17-sensors-13-08669" ref-type="bibr">17</xref>
] or an explosion [
<xref rid="b18-sensors-13-08669" ref-type="bibr">18</xref>
]. PVDF sensors' biomedical applications are new research hot-spots. By a build-in POSFET PVDF sensors on the inside wall of the grasper, the pressure generated by the endoscope grasper on tissues could be monitored [
<xref rid="b19-sensors-13-08669" ref-type="bibr">19</xref>
]. The same idea was also applied in lithotrities surgery [
<xref rid="b20-sensors-13-08669" ref-type="bibr">20</xref>
] and catheters [
<xref rid="b21-sensors-13-08669" ref-type="bibr">21</xref>
]. The intensity of shock waves generated in the surgery was fed back by a PVDF shock-wave hydrophone to guarantee the destruction of stones and the safety of benign tissues [
<xref rid="b20-sensors-13-08669" ref-type="bibr">20</xref>
], and pressure could be determined in real time flow measurements [
<xref rid="b21-sensors-13-08669" ref-type="bibr">21</xref>
]. Physiological pulse signals could be measured by a PVDF pressure sensor [
<xref rid="b22-sensors-13-08669" ref-type="bibr">22</xref>
]; its high sensitivity was evidenced by its comparison with an Electro Mechanical Film (EMFi) device [
<xref rid="b23-sensors-13-08669" ref-type="bibr">23</xref>
].</p>
<p>It is found in the limited review that the emphases of the reported studies are mainly focused on the preparation of PVDF piezoelectric polymer films in the early stage [
<xref rid="b1-sensors-13-08669" ref-type="bibr">1</xref>
<xref rid="b4-sensors-13-08669" ref-type="bibr">4</xref>
] and the exploration of PVDF related applications in the past twenty years [
<xref rid="b5-sensors-13-08669" ref-type="bibr">5</xref>
<xref rid="b22-sensors-13-08669" ref-type="bibr">22</xref>
]. It is accepted that the response of a PVDF senor is influenced by many conditions, such as the ambient temperature [
<xref rid="b24-sensors-13-08669" ref-type="bibr">24</xref>
], the smoothness of the touched object [
<xref rid="b11-sensors-13-08669" ref-type="bibr">11</xref>
] and the structure of electrodes [
<xref rid="b15-sensors-13-08669" ref-type="bibr">15</xref>
]. It is also noted that the sandwiched structure is adopted as the sensing element in almost all of the referenced reports. In this structure the front-side is always used as the sensing surface, and much attention has been paid to what kind of response signals could be obtained by PVDF sensors when their sensing surfaces suffered external pressure [
<xref rid="b12-sensors-13-08669" ref-type="bibr">12</xref>
,
<xref rid="b15-sensors-13-08669" ref-type="bibr">15</xref>
,
<xref rid="b21-sensors-13-08669" ref-type="bibr">21</xref>
], friction [
<xref rid="b15-sensors-13-08669" ref-type="bibr">15</xref>
], deformation [
<xref rid="b5-sensors-13-08669" ref-type="bibr">5</xref>
], impact with different energies [
<xref rid="b16-sensors-13-08669" ref-type="bibr">16</xref>
<xref rid="b18-sensors-13-08669" ref-type="bibr">18</xref>
,
<xref rid="b20-sensors-13-08669" ref-type="bibr">20</xref>
] or were touched with different materials [
<xref rid="b13-sensors-13-08669" ref-type="bibr">13</xref>
,
<xref rid="b14-sensors-13-08669" ref-type="bibr">14</xref>
],
<italic>etc.</italic>
, while, for their back side there are very few concerns, as we know. Different backstops were used in different reports, such as the aluminum cantilever [
<xref rid="b8-sensors-13-08669" ref-type="bibr">8</xref>
], plastics [
<xref rid="b9-sensors-13-08669" ref-type="bibr">9</xref>
], silicon wafers [
<xref rid="b21-sensors-13-08669" ref-type="bibr">21</xref>
], polydimethylsiloxane (PDMS) [
<xref rid="b22-sensors-13-08669" ref-type="bibr">22</xref>
] and rubber [
<xref rid="b23-sensors-13-08669" ref-type="bibr">23</xref>
], but the supporting materials' influence on PVDF sensors' response characteristics were seldom mentioned.</p>
<p>In this work, various backstops' influences on PVDF sensors' response to a falling shock are measured. The temporal voltage response signals for the same PVDF sensor are measured under three different supporting conditions, which are using a desk, rubber and a sponge as supporting materials, in order of increasing elasticity Two characteristics are discussed here, which are the peak-to-peak voltage (Vpp) of the response signals and the recovery time after suffering an impact. The qualitative analysis of their variation induced by backstops was presented as the coordinates of Vpp
<italic>vs.</italic>
the impact energy and the recovery time vs. the impact energy. The peak of the temporal response curves was suitable for a soft-supported PVDF sensor, while for rigid-supported ones, the changes of impact energy could be reflected by the areas under the response peaks of the temporal response curves, not the peaks' actual value.</p>
</sec>
<sec>
<label>2.</label>
<title>Experimental Section</title>
<sec sec-type="materials">
<label>2.1.</label>
<title>Materials</title>
<p>The PVDF piezoelectric film was purchased from Jinzhou KeXin Eectronic Materials Co. Ltd, (Jinzhou, China). The purchased sheet had been already stretched and poled. The type of PVDF film was KXP02, the thickness was 100 μm. The polarized polymer material had a zigzag molecular structure which as sketched in
<xref rid="f1-sensors-13-08669" ref-type="fig">Figure 1(a)</xref>
. The atoms of fluorine and hydrogen were separated in the two sides of the carbon chain. There were spontaneous dipoles in this structure. After polarization PVDF could exhibit piezoelectric properties, and the charge coefficient, d
<sub>31</sub>
, d
<sub>32</sub>
and d
<sub>33</sub>
were 17 ± 1, 5∼6 and 21 ± 1 pico-Coulomb per Newton (pC/N), respectively.</p>
<p>Copper foil (DongGuan FeiYing Electronic Material Co. Ltd., DongGuan, China) was used as the electrode material. The thickness was 0.02–0.05 mm and there was a conducting resin on one side of the foil.</p>
<p>A charge amplifier was constructed to transform the sensing charge generated by PVDF into an output voltage signal. The principal circuit and a photo of the charge amplifier are given in
<xref rid="f1-sensors-13-08669" ref-type="fig">Figure 1(c,d)</xref>
, respectively. Here CA 3140 was an integrated circuit operational amplifier (Harris Semiconductor Melbourne, Florida, USA), which was used to transfer the piezoelectric charges generated by the PVDF sensor. As shown in
<xref rid="f1-sensors-13-08669" ref-type="fig">Figure 1(c)</xref>
, the impact sensing charges were input from the IN port; by the used of the parallel resistor-capacitor (200 MΩ and 100 pF) in the negative feedback loop of CA 3140, an impact-sensing voltage signal could be output from the OUT port. Furthermore, a low pass filter was used to screen out the ultimate voltage signal.</p>
</sec>
<sec>
<label>2.2.</label>
<title>Experiments</title>
<p>The sensors were prepared based on PVDF films and copper foil with a sandwiched structure, as outlined in
<xref rid="f1-sensors-13-08669" ref-type="fig">Figure 1(b)</xref>
. First two out-leads were soldered on tailored copper foils, and the Cu foils were transmitted and conglutinated onto the surfaces of PVDF film by the conducting resin on the copper foils. Second, the PVDF sensors were laid on different backstops with flat surfaces, which were desk, rubber and sponge. Third, a falling path was formed with hardboard to guarantee the impacting force happened exactly on the PVDF sensors. Here, two kinds of weights, which were 20 and 50 g, were tested; the weights fell down freely from three different heights, 10, 15, 20 cm.</p>
</sec>
<sec>
<label>2.3.</label>
<title>Detection System and Equipments</title>
<p>The detection system was depicted in
<xref rid="f1-sensors-13-08669" ref-type="fig">Figure 1(d)</xref>
and the principal circuit for the charge amplifier was presented in
<xref rid="f1-sensors-13-08669" ref-type="fig">Figure 1(c)</xref>
. The charges generated by the PVDF sensors' piezoelectricity were introduced into the charge amplifier, through the capacitor in
<xref rid="f1-sensors-13-08669" ref-type="fig">Figure 1(c)</xref>
the charges' variation of the PVDF sensor could be transformed and screened out as a voltage signal. Finally, the impacting sensitive voltage signals were displayed by a TDS2022B oscilloscope (Tektronix Inc. Beaverton, OR, USA), and the data were collected by a computer through a USB port and analyzed by Origin Lab 8.1 (Origin Lab Corporation, Northampton, MA, USA).</p>
</sec>
</sec>
<sec>
<label>3.</label>
<title>Results and Discussion</title>
<sec>
<label>3.1.</label>
<title>PVDF Sensors' Voltage Response Results When Supported by the Desk</title>
<p>The shock response of the PVDF sensor was measured on the desk; the temporal voltage response curves are presented in
<xref rid="f2-sensors-13-08669" ref-type="fig">Figure 2(a)</xref>
. The falling impact conditions are adjusted according to
<xref rid="t1-sensors-13-08669" ref-type="table">Table 1</xref>
. That means higher impacting energy could be obtained when the heavier object fell from the higher position. The impact energies were estimated and are listed in
<xref rid="t1-sensors-13-08669" ref-type="table">Table 1</xref>
, by assuming all the mechanical potential energy was transformed to impact energy. To contrast their response characteristics under different conditions, the collected voltage signals were moved along the x-axis to aim at the same zero time.</p>
<p>The main explanation of the results is that the intensity of polarization in the PVDF film will be changed when it suffers a falling impact. To maintain the electric neutrality, it will release or capture charges from outside circuits as given in
<xref rid="f1-sensors-13-08669" ref-type="fig">Figure 1(c)</xref>
. The quantity of these charges is measured and transformed into a voltage signal by the measuring circuits, given in
<xref rid="f1-sensors-13-08669" ref-type="fig">Figure 1(c,d)</xref>
.</p>
<p>In
<xref rid="f2-sensors-13-08669" ref-type="fig">Figure 2(b)</xref>
, the abscissa is the impact energy; the approximate values are given in
<xref rid="t1-sensors-13-08669" ref-type="table">Table 1</xref>
. Similar curve shapes for these two analyzed items can be found in
<xref rid="f2-sensors-13-08669" ref-type="fig">Figure 2(b)</xref>
. Since the area was the product of Vpp and the recovery time, so it was reasonable to deduce that the difference of the recovery time under different impacting conditions was tiny. Approximately calculations indicated that the recovery time for the desk supported sensor was about 0.15∼0.18 s.</p>
<p>By comparing the horizontally moved curves in
<xref rid="f2-sensors-13-08669" ref-type="fig">Figure 2(a)</xref>
, it was found that: (1) under different impact conditions the positive peaks' amplitudes were not obviously changed, while the negative peaks were lowered, so the value of V
<sub>pp</sub>
must be changed by the increasing impact energy, as shown by the right y-axis in
<xref rid="f2-sensors-13-08669" ref-type="fig">Figure 2(b)</xref>
. (2) After the impact, the response voltages would return to their original value. In this progress there was a recovery time, a sample of which was depicted as a yellow double arrowhead line for the dashed black line in
<xref rid="f2-sensors-13-08669" ref-type="fig">Figure 2(a)</xref>
, but it seemed that the variation of their recovery time was very small. Furthermore, V
<sub>pp</sub>
and the integration areas under peaks were calculated by MATLAB, and their relation with the changing impacting energy was plotted in
<xref rid="f2-sensors-13-08669" ref-type="fig">Figure 2(b)</xref>
. Here V
<sub>pp</sub>
means the maximal output voltage minus the minimum output voltage, and integration areas were the areas under the curves from the highest to the lowest. These two items were plotted in a double- y-axis coordinates, as shown in
<xref rid="f2-sensors-13-08669" ref-type="fig">Figure 2(b)</xref>
.</p>
</sec>
<sec>
<label>3.2.</label>
<title>Results of the Elastically Supported PVDF Sensor</title>
<p>After changing the backstops, the experiments mentioned above were repeated on the 100 μm PVDF sensor used in
<xref rid="f2-sensors-13-08669" ref-type="fig">Figure 2</xref>
. Here two kinds of supporting materials were tested, which were sponge and rubber. The temporal response curves were plotted in
<xref rid="f3-sensors-13-08669" ref-type="fig">Figure 3(a-c)</xref>
. The values of Vpp for all the figures in
<xref rid="f3-sensors-13-08669" ref-type="fig">Figure 3(a-c)</xref>
, and
<xref rid="f2-sensors-13-08669" ref-type="fig">Figure 2(a)</xref>
are analyzed and plotted in
<xref rid="f3-sensors-13-08669" ref-type="fig">Figure 3(d)</xref>
.</p>
<p>It was found from
<xref rid="f3-sensors-13-08669" ref-type="fig">Figure 3(a)</xref>
, that the response curves' vibration of the sponge supported sensor was stronger than the rubber supported one under the same impact conditions. We deduced that the reason might lie in the elasticity of the supporting materials. The elasticity of sponge was bigger than that of rubber, so it offered a buffering action to PVDF film sensor and made it suffer a second elastic force after undergoing the impact, and this force could cause a second-piezoelectric-signal which was labeled in
<xref rid="f3-sensors-13-08669" ref-type="fig">Figure 3(a,c)</xref>
, while for the rubber supported one, this signal was relatively small. This deduction could be supported by further comparison with
<xref rid="f2-sensors-13-08669" ref-type="fig">Figure 2(a)</xref>
. On the hard material (the wooden desk) with almost no elasticity, no second-piezoelectric-signal was detected.</p>
<p>Another result that could be obtained in
<xref rid="f3-sensors-13-08669" ref-type="fig">Figure 3(a–c)</xref>
was that Vpp changed with the increasing impacting energy. Their relationship was proposed in
<xref rid="f3-sensors-13-08669" ref-type="fig">Figure 3(d)</xref>
. The ascending curves in
<xref rid="f3-sensors-13-08669" ref-type="fig">Figure 3(b)</xref>
indicated that with the increase in impact energies, the values of Vpp were enhanced, but the slopes of these curves were obviously different. Desk-supported sensors exhibited smaller V
<sub>pp</sub>
variation than rubber and sponge supported ones. For the same sensor (100 μm), the biggest curves' slope of Vpp
<italic>v</italic>
s. impacting energy was displayed by the sponge-supported one, the slope of which was 96.62 V/J., while for the same sensor, when it was supported by rubber, the slope was 82.255 V/J; and when it was supported by the desk the voltage response saturated quickly.</p>
</sec>
<sec>
<label>3.3.</label>
<title>Discussion</title>
<p>According to the experiments mentioned above, PVDF sensors could respond to a suffered impact and transform the mechanical energy into an electronic signal, but there were differences in their response signals when the sensors' supporting materials were changed.</p>
<p>Firstly, the impact power could be expressed in the value of the peak-to-peak voltage, so the V
<sub>pp</sub>
<italic>vs.</italic>
impact energy curve was chosen as the response curve. When the impact energy was in the range of 0.02∼0.08 J, the bigger V
<sub>pp</sub>
values could be transduced by a hard supported sensors (like the desk used in this work) than by the sponge or rubber supported ones, but the difference of impact energy could not be discriminated by the desk supported sensor, which was shown by the black and purple lines in
<xref rid="f3-sensors-13-08669" ref-type="fig">Figure 3(d)</xref>
, and the quantitative detection could be realized better by the sponge supported sensor than the rub ber or desk supported one, whose sensitivities were given in above subsection.</p>
<p>Secondly, the recovery time between differently supported sensors also varied. The green and black curves in
<xref rid="f3-sensors-13-08669" ref-type="fig">Figure 3(a–c)</xref>
represent the sponge supported sensor's response signals under three different conditions. These solid curves were magnified in the time range of 0.41∼0.66 s here, as shown in
<xref rid="f3-sensors-13-08669" ref-type="fig">Figure 3(a)</xref>
, to observe the sponge supported PVDF sensor's temporal response characteristics. It was deduced according to the black solid curve in
<xref rid="f4-sensors-13-08669" ref-type="fig">Figure 4(a)</xref>
, that the sensor might endure a sympathetic vibration after it suffered a falling impact induced by a 50 g weight dropped from a 10 cm height, since the amplitude output voltage was enhanced after suffering the impact and could not recover. Furthermore, the response time data was extracted and plotted under recovery-time
<italic>vs.</italic>
impacting-energy coordinates, shown in
<xref rid="f4-sensors-13-08669" ref-type="fig">Figure 4(b)</xref>
. As given in the explanation of
<xref rid="f2-sensors-13-08669" ref-type="fig">Figure 2(a)</xref>
, the recovery time for desk supported sensors was about 0.15 to 0.18 s. So the characteristic curve about recovering time for the desk supported sensor was nearly flat as shown by the fitted curve in
<xref rid="f4-sensors-13-08669" ref-type="fig">Figure 4(b)</xref>
, but for the sponge and rubber supported sensor the recovery time was up-and-down and no order could be found.</p>
<p>Thirdly, comparisons between
<xref rid="f2-sensors-13-08669" ref-type="fig">Figure 2(a)</xref>
, and
<xref rid="f3-sensors-13-08669" ref-type="fig">Figure 3(a–c)</xref>
indicate that, for the same sensor (100 μm), when the supporting materials are changed from desk, rubber, to sponge, more obvious second piezoelectric signals could be observed. This phenomenon was coincident with the elasticity of these three materials.</p>
</sec>
</sec>
<sec sec-type="conclusions">
<label>4.</label>
<title>Conclusions</title>
<p>The supporting materials' influence on a PVDF sensor's impact response was tested and discussed in this work. Three kinds of supporting materials were examined, which were a desk, rubber and sponge, as examples of three kinds of rigidity or elasticity. There were obvious response signals for the PVDF sensor supported by all these materials. Their response characteristics on different supporting materials could be evaluated by the curves of V
<sub>pp</sub>
<italic>vs.</italic>
the impact-energy. The desk supported PVDF sensor could convert the impact energy into a relatively bigger V
<sub>pp</sub>
than the same sensor supported by rubber or sponge, but the desk supported sensor was responsive enough to measure the impact intensity, because the values of V
<sub>pp</sub>
were almost constant when the impact energies were changed. Combined with the discussion about the recovery time, it was summarized that the rigidly supported PVDF sensor could transform the impact to a relatively higher voltage signal (V
<sub>pp</sub>
) in a constant time; it would be a choice for a shock controlled switch. Impact intensity measurements could be executed on the softly supported PVDF sensor, like sponge in this work.</p>
</sec>
</body>
<back>
<ack>
<p>This work was supported by the National Natural Science Foundation of China (Grant No. 60602002) and the Tianjin Science Technology Research Foundation of China (Grant No. 12JCZDJC22400).</p>
</ack>
<notes>
<title>Conflict of Interest</title>
<p>The authors declare no conflict of interest.</p>
</notes>
<ref-list>
<title>References</title>
<ref id="b1-sensors-13-08669">
<label>1.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kawai</surname>
<given-names>H.</given-names>
</name>
</person-group>
<article-title>The piezoelectricity of poly (vinylidene fluoride)</article-title>
<source>Jpn. J. Appl. Phys.</source>
<year>1969</year>
<volume>8</volume>
<fpage>975</fpage>
<lpage>976</lpage>
</element-citation>
</ref>
<ref id="b2-sensors-13-08669">
<label>2.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lima</surname>
<given-names>J.A.P.</given-names>
</name>
<name>
<surname>Marin</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>da Silva</surname>
<given-names>M.G.</given-names>
</name>
<name>
<surname>Sthel</surname>
<given-names>M.S.</given-names>
</name>
<name>
<surname>Cardoso</surname>
<given-names>S.L.</given-names>
</name>
<name>
<surname>Vargas</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Miranda</surname>
<given-names>L.C.M.</given-names>
</name>
</person-group>
<article-title>Application of the thermal wave resonator to the measurement of the thermal diffusivity of gas mixtures</article-title>
<source>Rev. Sci. Instr.</source>
<year>2001</year>
<volume>72</volume>
<fpage>1580</fpage>
<lpage>1582</lpage>
</element-citation>
</ref>
<ref id="b3-sensors-13-08669">
<label>3.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kepler</surname>
<given-names>R.G.</given-names>
</name>
</person-group>
<article-title>Piezoelectricity, pyroelectricity and ferroelectricity in organic materials</article-title>
<source>Ann. Rev. Phys. Chem.</source>
<year>1978</year>
<volume>29</volume>
<fpage>497</fpage>
<lpage>518</lpage>
</element-citation>
</ref>
<ref id="b4-sensors-13-08669">
<label>4.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fukada</surname>
<given-names>E.</given-names>
</name>
</person-group>
<article-title>History and recent progress in piezoelectric polymer research</article-title>
<source>IEEE Tran. Ultrason. Ferroelectr.</source>
<year>1998</year>
<volume>47</volume>
<fpage>597</fpage>
<lpage>605</lpage>
</element-citation>
</ref>
<ref id="b5-sensors-13-08669">
<label>5.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Huh</surname>
<given-names>Y.-H.</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>J.I.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>J.H.</given-names>
</name>
<name>
<surname>Hong</surname>
<given-names>S.G.</given-names>
</name>
<name>
<surname>Park</surname>
<given-names>J.H.</given-names>
</name>
</person-group>
<article-title>Application of PVDF film sensor to detect early damage in wind turbine blade components</article-title>
<source>Procedia Eng.</source>
<year>2011</year>
<volume>10</volume>
<fpage>3304</fpage>
<lpage>3309</lpage>
</element-citation>
</ref>
<ref id="b6-sensors-13-08669">
<label>6.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Xu</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Dapinoa</surname>
<given-names>M.J.</given-names>
</name>
<name>
<surname>Gallego Perez</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Hansford</surname>
<given-names>D.</given-names>
</name>
</person-group>
<article-title>Microphone based on Polyvinylidene MahapatraFluoride (PVDF) micro-pillars and patterned electrodes</article-title>
<source>Sens. Actuators A-Phys.</source>
<year>2009</year>
<volume>153</volume>
<fpage>24</fpage>
<lpage>32</lpage>
</element-citation>
</ref>
<ref id="b7-sensors-13-08669">
<label>7.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Toda</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Dahl</surname>
<given-names>J.</given-names>
</name>
</person-group>
<article-title>PVDF corrugated transducer for ultrasonic ranging sensor</article-title>
<source>Sens. Actuators A-Phys.</source>
<year>2007</year>
<volume>134</volume>
<fpage>427</fpage>
<lpage>435</lpage>
</element-citation>
</ref>
<ref id="b8-sensors-13-08669">
<label>8.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rathod</surname>
<given-names>V.T.</given-names>
</name>
<name>
<surname>Mahapatra</surname>
<given-names>D.R.</given-names>
</name>
<name>
<surname>Jain</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Gayathri</surname>
<given-names>A.</given-names>
</name>
</person-group>
<article-title>Characterization of a large-area PVDF thin film for electromechanical and ultrasonic sensing applications</article-title>
<source>Sens. Actuators A-Phys.</source>
<year>2010</year>
<volume>163</volume>
<fpage>164</fpage>
<lpage>171</lpage>
</element-citation>
</ref>
<ref id="b9-sensors-13-08669">
<label>9.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Seminara</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Capurro</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Cirillo</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Cannata</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Valle</surname>
<given-names>M.</given-names>
</name>
</person-group>
<article-title>Electromechanical characterization of piezoelectric PVDF polymer films for tactile sensors in robotics applications</article-title>
<source>Sens. Actuators A-Phys.</source>
<year>2011</year>
<volume>169</volume>
<fpage>49</fpage>
<lpage>58</lpage>
</element-citation>
</ref>
<ref id="b10-sensors-13-08669">
<label>10.</label>
<element-citation publication-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Dahiya</surname>
<given-names>R.S.</given-names>
</name>
<name>
<surname>Valle</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Metta</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Lorenzelli</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Adami</surname>
<given-names>A.</given-names>
</name>
</person-group>
<article-title>Design and Fabrication of Posfet Devices for Tactile Sensing</article-title>
<conf-name>Proceedings of the International Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS)</conf-name>
<conf-loc>Denver, CO, USA</conf-loc>
<conf-date>21–25 June 2009</conf-date>
<fpage>1881</fpage>
<lpage>1884</lpage>
</element-citation>
</ref>
<ref id="b11-sensors-13-08669">
<label>11.</label>
<element-citation publication-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Tsuchimi</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Okuyama</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Tanaka</surname>
<given-names>M.</given-names>
</name>
</person-group>
<article-title>Development of a Haptic Sensor System for Monitoring Human Skin Conditions</article-title>
<conf-name>Proceedings of the 13th International Conference on Biomedical Engineering</conf-name>
<conf-loc>Singapore</conf-loc>
<conf-date>3–6 December 2008</conf-date>
<fpage>2219</fpage>
<lpage>2222</lpage>
</element-citation>
</ref>
<ref id="b12-sensors-13-08669">
<label>12.</label>
<element-citation publication-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Matsunaga</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Zengin</surname>
<given-names>A.T.</given-names>
</name>
<name>
<surname>Kawaji</surname>
<given-names>S.</given-names>
</name>
</person-group>
<article-title>Evaluation of Multilayered Pain Sensor Model of Human Skin</article-title>
<conf-name>Proceedings of the ICROS-SICE International Joint Conference</conf-name>
<conf-loc>Fukuoka, Japan</conf-loc>
<conf-date>18–21 August 2009</conf-date>
<fpage>3840</fpage>
<lpage>3845</lpage>
</element-citation>
</ref>
<ref id="b13-sensors-13-08669">
<label>13.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gao</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Gao</surname>
<given-names>R.</given-names>
</name>
</person-group>
<article-title>A PVDF film sensor for material identification</article-title>
<source>Sens. Actuators A-Phys.</source>
<year>1990</year>
<volume>23</volume>
<fpage>886</fpage>
<lpage>889</lpage>
</element-citation>
</ref>
<ref id="b14-sensors-13-08669">
<label>14.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kimoto</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Sugitani</surname>
<given-names>N.</given-names>
</name>
</person-group>
<article-title>A new sensing method based on PVDF film for material identification</article-title>
<source>Meas. Sci. Technol.</source>
<year>2010</year>
<pub-id pub-id-type="doi">10.1088/0957-0233/21/7/075202</pub-id>
</element-citation>
</ref>
<ref id="b15-sensors-13-08669">
<label>15.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chuang</surname>
<given-names>C.H.</given-names>
</name>
<name>
<surname>Liou</surname>
<given-names>Y.R.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>C.W.</given-names>
</name>
</person-group>
<article-title>Detection system of incident slippage and friction coefficient based on a flexible tactile sensor with structural electrodes</article-title>
<source>Sens. Actuators A-Phys.</source>
<year>2012</year>
<volume>188</volume>
<fpage>48</fpage>
<lpage>55</lpage>
</element-citation>
</ref>
<ref id="b16-sensors-13-08669">
<label>16.</label>
<element-citation publication-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Bauer</surname>
<given-names>F.</given-names>
</name>
</person-group>
<article-title>Advances in Piezoelectric PVDF Shock Compression Sensors</article-title>
<conf-name>Proceedings of the 10th International Symposium on Electrets</conf-name>
<conf-loc>Athens, Greece</conf-loc>
<conf-date>22–24 September 1999</conf-date>
<fpage>647</fpage>
<lpage>650</lpage>
</element-citation>
</ref>
<ref id="b17-sensors-13-08669">
<label>17.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Tang</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Zheng</surname>
<given-names>H.</given-names>
</name>
</person-group>
<article-title>A study of impact piezoelectric property of PVDF stress gauges</article-title>
<source>J. Exp. Mech.</source>
<year>2009</year>
<volume>24</volume>
<fpage>244</fpage>
<lpage>250</lpage>
</element-citation>
</ref>
<ref id="b18-sensors-13-08669">
<label>18.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bauer</surname>
<given-names>F.</given-names>
</name>
</person-group>
<article-title>PVDF shock sensors: Applications to polar materials and high explosives</article-title>
<source>IEEE Tran. Ultrason. Ferroelectr.</source>
<year>2000</year>
<volume>47</volume>
<fpage>1448</fpage>
<lpage>1454</lpage>
</element-citation>
</ref>
<ref id="b19-sensors-13-08669">
<label>19.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dargahi</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Parameswaran</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Payandeh</surname>
<given-names>S.</given-names>
</name>
</person-group>
<article-title>Micromachined piezoelectric tactile sensor for an endoscopic grasper—Theory, Fabrication and experiments</article-title>
<source>J. Microelectromech. Syst.</source>
<year>2000</year>
<volume>9</volume>
<fpage>329</fpage>
<lpage>335</lpage>
</element-citation>
</ref>
<ref id="b20-sensors-13-08669">
<label>20.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tavakkoli</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Birer</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Cathignol</surname>
<given-names>D.</given-names>
</name>
</person-group>
<article-title>Development of a PVDF low-cost shock-wave hydrophone</article-title>
<source>Shock Waves</source>
<year>1996</year>
<volume>5</volume>
<fpage>369</fpage>
<lpage>374</lpage>
</element-citation>
</ref>
<ref id="b21-sensors-13-08669">
<label>21.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sharma</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Je</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Gill</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>X.J.</given-names>
</name>
</person-group>
<article-title>Patterning piezoelectric thin film PVDF–TrFE based pressure sensor for catheter application</article-title>
<source>Sens. Actuators A-Phys.</source>
<year>2012</year>
<volume>177</volume>
<fpage>87</fpage>
<lpage>92</lpage>
</element-citation>
</ref>
<ref id="b22-sensors-13-08669">
<label>22.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chiu</surname>
<given-names>Y.Y.</given-names>
</name>
<name>
<surname>Lin</surname>
<given-names>W.Y.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>H.Y.</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>S.B.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>M.H.</given-names>
</name>
</person-group>
<article-title>Development of a piezoelectric polyvinylidene fluoride (PVDF) polymer-based sensor patch for simultaneous heartbeat and respiration monitoring</article-title>
<source>Sens. Actuators A-Phys.</source>
<year>2013</year>
<volume>189</volume>
<fpage>328</fpage>
<lpage>334</lpage>
</element-citation>
</ref>
<ref id="b23-sensors-13-08669">
<label>23.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rajala</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Lekkala</surname>
<given-names>J.</given-names>
</name>
</person-group>
<article-title>Film-Type sensor materials PVDF and EMFi in measurement of cardiorespiratory signals—A review</article-title>
<source>IEEE Sens. J.</source>
<year>2012</year>
<volume>12</volume>
<fpage>439</fpage>
<lpage>446</lpage>
</element-citation>
</ref>
<ref id="b24-sensors-13-08669">
<label>24.</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ngalamou</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Noury</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Chamberod</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Benech</surname>
<given-names>P.</given-names>
</name>
</person-group>
<article-title>Analysis of the sensitivity and the temperature influence of a static force sensor based on a PVDF resonator</article-title>
<source>Sens. Actuators A-Phys.</source>
<year>1996</year>
<volume>57</volume>
<fpage>173</fpage>
<lpage>177</lpage>
</element-citation>
</ref>
</ref-list>
</back>
<floats-group>
<fig id="f1-sensors-13-08669" position="float">
<label>Figure 1.</label>
<caption>
<p>Sketch maps for the PVDF sensor and the related detection system: (
<bold>a</bold>
) the molecular structure of PVDF; (
<bold>b</bold>
) the sandwiched structure of PVDF sensor; (
<bold>c</bold>
) the principle circuit of the charge amplifier used to transform piezoelectric charges generated by PVDF sensor to a voltage signal; (
<bold>d</bold>
) the outline for the experimental setup and the detection system.</p>
</caption>
<graphic xlink:href="sensors-13-08669f1"></graphic>
</fig>
<fig id="f2-sensors-13-08669" position="float">
<label>Figure 2.</label>
<caption>
<p>Response of PVDF sensor on the desk: (
<bold>a</bold>
) temporal response curves for the sensors prepared from 100 μm PVDF film when the weights were 50, 20 g and the falling height was changed from 10 to 20 cm; (
<bold>b</bold>
) the analysis of peaks' area and the peak-to-peak voltage (V
<sub>pp</sub>
)
<italic>vs.</italic>
the impacting energy.</p>
</caption>
<graphic xlink:href="sensors-13-08669f2"></graphic>
</fig>
<fig id="f3-sensors-13-08669" position="float">
<label>Figure 3.</label>
<caption>
<p>Response of PVDF sensors on sponge and rubber. (
<bold>a</bold>
-
<bold>c</bold>
) temporal response curves for the PVDF sensor prepared from 100 μm PVDF film, the weights were 50, 20 g, and the falling height was 10, 15, 20 cm; (
<bold>d</bold>
) the analysis of the peak-to-peak voltage (Vpp)
<italic>vs.</italic>
the impact energy for the same sensor prepared from 100 μm PVDF film.</p>
</caption>
<graphic xlink:href="sensors-13-08669f3a"></graphic>
<graphic xlink:href="sensors-13-08669f3b"></graphic>
</fig>
<fig id="f4-sensors-13-08669" position="float">
<label>Figure 4.</label>
<caption>
<p>Comparison of the recovery time of the PVDF sensor after suffering impact, when it was supported by three backstops which were desk, rubber and sponge, respectively. (
<bold>a</bold>
) The enlarged temporal response curves of the sponge supported sensor after being impacted by 50 g weight from different height, 10, 15 and 20 cm. (
<bold>b</bold>
) The data of the PVDF sensor's recovery time in the coordinates of recovery-time
<italic>vs.</italic>
impact-energy, which were extracted from
<xref rid="f2-sensors-13-08669" ref-type="fig">Figure 2(a)</xref>
and
<xref rid="f3-sensors-13-08669" ref-type="fig">Figure 3(a)</xref>
.</p>
</caption>
<graphic xlink:href="sensors-13-08669f4"></graphic>
</fig>
<table-wrap id="t1-sensors-13-08669" position="float">
<label>Table 1.</label>
<caption>
<p>The approximate impact energy.</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="center" valign="top" rowspan="1" colspan="1">
<bold>Mass (g)</bold>
</th>
<th align="center" valign="top" rowspan="1" colspan="1">
<bold>Height (cm)</bold>
</th>
<th align="center" valign="top" rowspan="1" colspan="1">
<bold>Impact energy (J)</bold>
</th>
</tr>
</thead>
<tbody>
<tr>
<td align="center" valign="top" rowspan="1" colspan="1">20</td>
<td align="center" valign="top" rowspan="1" colspan="1">10</td>
<td align="center" valign="top" rowspan="1" colspan="1">0.0196</td>
</tr>
<tr>
<td align="center" valign="top" rowspan="1" colspan="1">20</td>
<td align="center" valign="top" rowspan="1" colspan="1">15</td>
<td align="center" valign="top" rowspan="1" colspan="1">0.0294</td>
</tr>
<tr>
<td align="center" valign="top" rowspan="1" colspan="1">20</td>
<td align="center" valign="top" rowspan="1" colspan="1">20</td>
<td align="center" valign="top" rowspan="1" colspan="1">0.0392</td>
</tr>
<tr>
<td align="center" valign="top" rowspan="1" colspan="1">50</td>
<td align="center" valign="top" rowspan="1" colspan="1">10</td>
<td align="center" valign="top" rowspan="1" colspan="1">0.049</td>
</tr>
<tr>
<td align="center" valign="top" rowspan="1" colspan="1">50</td>
<td align="center" valign="top" rowspan="1" colspan="1">15</td>
<td align="center" valign="top" rowspan="1" colspan="1">0.0735</td>
</tr>
<tr>
<td align="center" valign="top" rowspan="1" colspan="1">50</td>
<td align="center" valign="top" rowspan="1" colspan="1">20</td>
<td align="center" valign="top" rowspan="1" colspan="1">0.098</td>
</tr>
</tbody>
</table>
</table-wrap>
</floats-group>
</pmc>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Chen, Xinjuan" sort="Chen, Xinjuan" uniqKey="Chen X" first="Xinjuan" last="Chen">Xinjuan Chen</name>
<name sortKey="Jia, Yunfang" sort="Jia, Yunfang" uniqKey="Jia Y" first="Yunfang" last="Jia">Yunfang Jia</name>
<name sortKey="Ju, Cheng" sort="Ju, Cheng" uniqKey="Ju C" first="Cheng" last="Ju">Cheng Ju</name>
<name sortKey="Li, Longhua" sort="Li, Longhua" uniqKey="Li L" first="Longhua" last="Li">Longhua Li</name>
<name sortKey="Ni, Qingshan" sort="Ni, Qingshan" uniqKey="Ni Q" first="Qingshan" last="Ni">Qingshan Ni</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Pmc/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001329 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Checkpoint/biblio.hfd -nk 001329 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Pmc
   |étape=   Checkpoint
   |type=    RBID
   |clé=     PMC:3758616
   |texte=   Dependence of the Impact Response of Polyvinylidene Fluoride Sensors on Their Supporting Materials' Elasticity
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Checkpoint/RBID.i   -Sk "pubmed:23881132" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024