Spontaneous disinsertion of a multipiece foldable acrylic intraocular lens haptic 3 and 12 months after implantation

Identifieur interne : 000F92 ( PascalFrancis/Corpus ); précédent : 000F91; suivant : 000F93

Spontaneous disinsertion of a multipiece foldable acrylic intraocular lens haptic 3 and 12 months after implantation

Auteurs : YONG MING POR ; Soon-Phaik Chee

Source :

RBID : Pascal:04-0298049

Descripteurs français

English descriptors

Abstract

We report 2 cases of spontaneous postoperative haptic disinsertion with the Alcon AcrySof® MA60BM posterior chamber intraocular lens (PC IOL). A 14-year-old girl with a history of acute retinal necrosis and pars plana vitrectomy with lensectomy for retinal detachment repair had secondary implantation of a PC IOL in the ciliary sulcus. Three months later, the superior haptic disinserted from the optic and dislocated into the anterior chamber. In the second case, a 22-year-old man had lens aspiration and PC IOL implantation in the capsular bag. One year after surgery, the PC IOL had a similar problem, with the disinserted superior haptic remaining in the capsular bag while the optic and inferior haptic dislocated into the anterior chamber. In both patients, the PC lOLs were exchanged for rigid single-piece PC lOLs. The patients have had no further problems.

Notice en format standard (ISO 2709)

Pour connaître la documentation sur le format Inist Standard.

pA  
A01 01  1    @0 0886-3350
A02 01      @0 JCSUEV
A03   1    @0 J. cataract refractive surg.
A05       @2 30
A06       @2 5
A08 01  1  ENG  @1 Spontaneous disinsertion of a multipiece foldable acrylic intraocular lens haptic 3 and 12 months after implantation
A11 01  1    @1 YONG MING POR
A11 02  1    @1 CHEE (Soon-Phaik)
A14 01      @1 Singapore National Eye Centre @2 Singapore @3 SGP @Z 1 aut. @Z 2 aut.
A20       @1 1139-1142
A21       @1 2004
A23 01      @0 ENG
A43 01      @1 INIST @2 20937 @5 354000114546840320
A44       @0 0000 @1 © 2004 INIST-CNRS. All rights reserved.
A45       @0 7 ref.
A47 01  1    @0 04-0298049
A60       @1 P @3 EC
A61       @0 A
A64 01  1    @0 Journal of cataract and refractive surgery
A66 01      @0 USA
C01 01    ENG  @0 We report 2 cases of spontaneous postoperative haptic disinsertion with the Alcon AcrySof® MA60BM posterior chamber intraocular lens (PC IOL). A 14-year-old girl with a history of acute retinal necrosis and pars plana vitrectomy with lensectomy for retinal detachment repair had secondary implantation of a PC IOL in the ciliary sulcus. Three months later, the superior haptic disinserted from the optic and dislocated into the anterior chamber. In the second case, a 22-year-old man had lens aspiration and PC IOL implantation in the capsular bag. One year after surgery, the PC IOL had a similar problem, with the disinserted superior haptic remaining in the capsular bag while the optic and inferior haptic dislocated into the anterior chamber. In both patients, the PC lOLs were exchanged for rigid single-piece PC lOLs. The patients have had no further problems.
C02 01  X    @0 002B25B
C03 01  X  FRE  @0 Spontané @5 02
C03 01  X  ENG  @0 Spontaneous @5 02
C03 01  X  SPA  @0 Espontáneo @5 02
C03 02  X  FRE  @0 Acrylique dérivé polymère @2 NK @5 03
C03 02  X  ENG  @0 Acrylic polymer @2 NK @5 03
C03 02  X  SPA  @0 Acrilico derivado polímero @2 NK @5 03
C03 03  X  FRE  @0 Implantation @5 05
C03 03  X  ENG  @0 Implantation @5 05
C03 03  X  SPA  @0 Implantación @5 05
C03 04  X  FRE  @0 Chirurgie @5 06
C03 04  X  ENG  @0 Surgery @5 06
C03 04  X  SPA  @0 Cirugía @5 06
C03 05  X  FRE  @0 Ophtalmologie @5 08
C03 05  X  ENG  @0 Ophthalmology @5 08
C03 05  X  SPA  @0 Oftalmología @5 08
C03 06  X  FRE  @0 Traitement @5 25
C03 06  X  ENG  @0 Treatment @5 25
C03 06  X  SPA  @0 Tratamiento @5 25
N21       @1 180
N44 01      @1 OTO
N82       @1 OTO

Format Inist (serveur)

NO : PASCAL 04-0298049 INIST
ET : Spontaneous disinsertion of a multipiece foldable acrylic intraocular lens haptic 3 and 12 months after implantation
AU : YONG MING POR; CHEE (Soon-Phaik)
AF : Singapore National Eye Centre/Singapore/Singapour (1 aut., 2 aut.)
DT : Publication en série; Etude de cas, cas et faits cliniques; Niveau analytique
SO : Journal of cataract and refractive surgery; ISSN 0886-3350; Coden JCSUEV; Etats-Unis; Da. 2004; Vol. 30; No. 5; Pp. 1139-1142; Bibl. 7 ref.
LA : Anglais
EA : We report 2 cases of spontaneous postoperative haptic disinsertion with the Alcon AcrySof® MA60BM posterior chamber intraocular lens (PC IOL). A 14-year-old girl with a history of acute retinal necrosis and pars plana vitrectomy with lensectomy for retinal detachment repair had secondary implantation of a PC IOL in the ciliary sulcus. Three months later, the superior haptic disinserted from the optic and dislocated into the anterior chamber. In the second case, a 22-year-old man had lens aspiration and PC IOL implantation in the capsular bag. One year after surgery, the PC IOL had a similar problem, with the disinserted superior haptic remaining in the capsular bag while the optic and inferior haptic dislocated into the anterior chamber. In both patients, the PC lOLs were exchanged for rigid single-piece PC lOLs. The patients have had no further problems.
CC : 002B25B
FD : Spontané; Acrylique dérivé polymère; Implantation; Chirurgie; Ophtalmologie; Traitement
ED : Spontaneous; Acrylic polymer; Implantation; Surgery; Ophthalmology; Treatment
SD : Espontáneo; Acrilico derivado polímero; Implantación; Cirugía; Oftalmología; Tratamiento
LO : INIST-20937.354000114546840320
ID : 04-0298049

Links to Exploration step

Pascal:04-0298049

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">Spontaneous disinsertion of a multipiece foldable acrylic intraocular lens haptic 3 and 12 months after implantation</title>
<author>
<name sortKey="Yong Ming Por" sort="Yong Ming Por" uniqKey="Yong Ming Por" last="Yong Ming Por">YONG MING POR</name>
<affiliation>
<inist:fA14 i1="01">
<s1>Singapore National Eye Centre</s1>
<s2>Singapore</s2>
<s3>SGP</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author>
<name sortKey="Chee, Soon Phaik" sort="Chee, Soon Phaik" uniqKey="Chee S" first="Soon-Phaik" last="Chee">Soon-Phaik Chee</name>
<affiliation>
<inist:fA14 i1="01">
<s1>Singapore National Eye Centre</s1>
<s2>Singapore</s2>
<s3>SGP</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">04-0298049</idno>
<date when="2004">2004</date>
<idno type="stanalyst">PASCAL 04-0298049 INIST</idno>
<idno type="RBID">Pascal:04-0298049</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000F92</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">Spontaneous disinsertion of a multipiece foldable acrylic intraocular lens haptic 3 and 12 months after implantation</title>
<author>
<name sortKey="Yong Ming Por" sort="Yong Ming Por" uniqKey="Yong Ming Por" last="Yong Ming Por">YONG MING POR</name>
<affiliation>
<inist:fA14 i1="01">
<s1>Singapore National Eye Centre</s1>
<s2>Singapore</s2>
<s3>SGP</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author>
<name sortKey="Chee, Soon Phaik" sort="Chee, Soon Phaik" uniqKey="Chee S" first="Soon-Phaik" last="Chee">Soon-Phaik Chee</name>
<affiliation>
<inist:fA14 i1="01">
<s1>Singapore National Eye Centre</s1>
<s2>Singapore</s2>
<s3>SGP</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</analytic>
<series>
<title level="j" type="main">Journal of cataract and refractive surgery</title>
<title level="j" type="abbreviated">J. cataract refractive surg.</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="2004">2004</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">Journal of cataract and refractive surgery</title>
<title level="j" type="abbreviated">J. cataract refractive surg.</title>
<idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Acrylic polymer</term>
<term>Implantation</term>
<term>Ophthalmology</term>
<term>Spontaneous</term>
<term>Surgery</term>
<term>Treatment</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Spontané</term>
<term>Acrylique dérivé polymère</term>
<term>Implantation</term>
<term>Chirurgie</term>
<term>Ophtalmologie</term>
<term>Traitement</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">We report 2 cases of spontaneous postoperative haptic disinsertion with the Alcon AcrySof® MA60BM posterior chamber intraocular lens (PC IOL). A 14-year-old girl with a history of acute retinal necrosis and pars plana vitrectomy with lensectomy for retinal detachment repair had secondary implantation of a PC IOL in the ciliary sulcus. Three months later, the superior haptic disinserted from the optic and dislocated into the anterior chamber. In the second case, a 22-year-old man had lens aspiration and PC IOL implantation in the capsular bag. One year after surgery, the PC IOL had a similar problem, with the disinserted superior haptic remaining in the capsular bag while the optic and inferior haptic dislocated into the anterior chamber. In both patients, the PC lOLs were exchanged for rigid single-piece PC lOLs. The patients have had no further problems.</div>
</front>
</TEI>
<inist>
<standard h6="B">
<pA>
<fA01 i1="01" i2="1">
<s0>0886-3350</s0>
</fA01>
<fA02 i1="01">
<s0>JCSUEV</s0>
</fA02>
<fA03 i2="1">
<s0>J. cataract refractive surg.</s0>
</fA03>
<fA05>
<s2>30</s2>
</fA05>
<fA06>
<s2>5</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG">
<s1>Spontaneous disinsertion of a multipiece foldable acrylic intraocular lens haptic 3 and 12 months after implantation</s1>
</fA08>
<fA11 i1="01" i2="1">
<s1>YONG MING POR</s1>
</fA11>
<fA11 i1="02" i2="1">
<s1>CHEE (Soon-Phaik)</s1>
</fA11>
<fA14 i1="01">
<s1>Singapore National Eye Centre</s1>
<s2>Singapore</s2>
<s3>SGP</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
</fA14>
<fA20>
<s1>1139-1142</s1>
</fA20>
<fA21>
<s1>2004</s1>
</fA21>
<fA23 i1="01">
<s0>ENG</s0>
</fA23>
<fA43 i1="01">
<s1>INIST</s1>
<s2>20937</s2>
<s5>354000114546840320</s5>
</fA43>
<fA44>
<s0>0000</s0>
<s1>© 2004 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45>
<s0>7 ref.</s0>
</fA45>
<fA47 i1="01" i2="1">
<s0>04-0298049</s0>
</fA47>
<fA60>
<s1>P</s1>
<s3>EC</s3>
</fA60>
<fA61>
<s0>A</s0>
</fA61>
<fA64 i1="01" i2="1">
<s0>Journal of cataract and refractive surgery</s0>
</fA64>
<fA66 i1="01">
<s0>USA</s0>
</fA66>
<fC01 i1="01" l="ENG">
<s0>We report 2 cases of spontaneous postoperative haptic disinsertion with the Alcon AcrySof® MA60BM posterior chamber intraocular lens (PC IOL). A 14-year-old girl with a history of acute retinal necrosis and pars plana vitrectomy with lensectomy for retinal detachment repair had secondary implantation of a PC IOL in the ciliary sulcus. Three months later, the superior haptic disinserted from the optic and dislocated into the anterior chamber. In the second case, a 22-year-old man had lens aspiration and PC IOL implantation in the capsular bag. One year after surgery, the PC IOL had a similar problem, with the disinserted superior haptic remaining in the capsular bag while the optic and inferior haptic dislocated into the anterior chamber. In both patients, the PC lOLs were exchanged for rigid single-piece PC lOLs. The patients have had no further problems.</s0>
</fC01>
<fC02 i1="01" i2="X">
<s0>002B25B</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE">
<s0>Spontané</s0>
<s5>02</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG">
<s0>Spontaneous</s0>
<s5>02</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA">
<s0>Espontáneo</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE">
<s0>Acrylique dérivé polymère</s0>
<s2>NK</s2>
<s5>03</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG">
<s0>Acrylic polymer</s0>
<s2>NK</s2>
<s5>03</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA">
<s0>Acrilico derivado polímero</s0>
<s2>NK</s2>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE">
<s0>Implantation</s0>
<s5>05</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG">
<s0>Implantation</s0>
<s5>05</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA">
<s0>Implantación</s0>
<s5>05</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE">
<s0>Chirurgie</s0>
<s5>06</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG">
<s0>Surgery</s0>
<s5>06</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA">
<s0>Cirugía</s0>
<s5>06</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE">
<s0>Ophtalmologie</s0>
<s5>08</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG">
<s0>Ophthalmology</s0>
<s5>08</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA">
<s0>Oftalmología</s0>
<s5>08</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE">
<s0>Traitement</s0>
<s5>25</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG">
<s0>Treatment</s0>
<s5>25</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA">
<s0>Tratamiento</s0>
<s5>25</s5>
</fC03>
<fN21>
<s1>180</s1>
</fN21>
<fN44 i1="01">
<s1>OTO</s1>
</fN44>
<fN82>
<s1>OTO</s1>
</fN82>
</pA>
</standard>
<server>
<NO>PASCAL 04-0298049 INIST</NO>
<ET>Spontaneous disinsertion of a multipiece foldable acrylic intraocular lens haptic 3 and 12 months after implantation</ET>
<AU>YONG MING POR; CHEE (Soon-Phaik)</AU>
<AF>Singapore National Eye Centre/Singapore/Singapour (1 aut., 2 aut.)</AF>
<DT>Publication en série; Etude de cas, cas et faits cliniques; Niveau analytique</DT>
<SO>Journal of cataract and refractive surgery; ISSN 0886-3350; Coden JCSUEV; Etats-Unis; Da. 2004; Vol. 30; No. 5; Pp. 1139-1142; Bibl. 7 ref.</SO>
<LA>Anglais</LA>
<EA>We report 2 cases of spontaneous postoperative haptic disinsertion with the Alcon AcrySof® MA60BM posterior chamber intraocular lens (PC IOL). A 14-year-old girl with a history of acute retinal necrosis and pars plana vitrectomy with lensectomy for retinal detachment repair had secondary implantation of a PC IOL in the ciliary sulcus. Three months later, the superior haptic disinserted from the optic and dislocated into the anterior chamber. In the second case, a 22-year-old man had lens aspiration and PC IOL implantation in the capsular bag. One year after surgery, the PC IOL had a similar problem, with the disinserted superior haptic remaining in the capsular bag while the optic and inferior haptic dislocated into the anterior chamber. In both patients, the PC lOLs were exchanged for rigid single-piece PC lOLs. The patients have had no further problems.</EA>
<CC>002B25B</CC>
<FD>Spontané; Acrylique dérivé polymère; Implantation; Chirurgie; Ophtalmologie; Traitement</FD>
<ED>Spontaneous; Acrylic polymer; Implantation; Surgery; Ophthalmology; Treatment</ED>
<SD>Espontáneo; Acrilico derivado polímero; Implantación; Cirugía; Oftalmología; Tratamiento</SD>
<LO>INIST-20937.354000114546840320</LO>
<ID>04-0298049</ID>
</server>
</inist>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PascalFrancis/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000F92 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Corpus/biblio.hfd -nk 000F92 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PascalFrancis
   |étape=   Corpus
   |type=    RBID
   |clé=     Pascal:04-0298049
   |texte=   Spontaneous disinsertion of a multipiece foldable acrylic intraocular lens haptic 3 and 12 months after implantation
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024