"Luggage-tag" suture fixation of partially dislocated intraocular lenses

Identifieur interne : 001178 ( PascalFrancis/Checkpoint ); précédent : 001177; suivant : 001179

"Luggage-tag" suture fixation of partially dislocated intraocular lenses

Auteurs : Steven R. Virata [États-Unis] ; Nancy M. Holekamp [États-Unis] ; Travis A. Meredith [États-Unis]

Source :

RBID : Pascal:01-0388286

Descripteurs français

English descriptors

Abstract

There are many techniques for sulcus-suturing dislocated or partially dislocated intraocular lenses. Many involve passing suture or a knot around the end of the haptic before securing the suture to the sclera. However, in some patients, the tip of the dislocated haptic cannot be visualized. We describe a suturing method using vitrectomy techniques that was used in two patients when the end of the haptic could not be visualized. The technique involves passing an untied loop of double-armed suture under the haptic so that it emerges upward between the haptic and the optic. The loop of suture is regrasped from above the haptic and externalized. The free ends are passed through the loop in a manner analogous to a luggage tag, and the knot is secured. This technique may be useful in patients where the tip of the haptic cannot be visualized, or in patients requiring minimal manipulation of the intraocular lens.


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

Pascal:01-0388286

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">"Luggage-tag" suture fixation of partially dislocated intraocular lenses</title>
<author>
<name sortKey="Virata, Steven R" sort="Virata, Steven R" uniqKey="Virata S" first="Steven R." last="Virata">Steven R. Virata</name>
<affiliation wicri:level="4">
<inist:fA14 i1="01">
<s1>Barnes Retina Institute and the Department of Ophthalmology and Visual Sciences, Washington University School of Medicine</s1>
<s2>St. Louis, Missouri</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName>
<region type="state">Missouri (État)</region>
</placeName>
<orgName type="university">École de médecine (Université Washington de Saint-Louis)</orgName>
</affiliation>
</author>
<author>
<name sortKey="Holekamp, Nancy M" sort="Holekamp, Nancy M" uniqKey="Holekamp N" first="Nancy M." last="Holekamp">Nancy M. Holekamp</name>
<affiliation wicri:level="4">
<inist:fA14 i1="01">
<s1>Barnes Retina Institute and the Department of Ophthalmology and Visual Sciences, Washington University School of Medicine</s1>
<s2>St. Louis, Missouri</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName>
<region type="state">Missouri (État)</region>
</placeName>
<orgName type="university">École de médecine (Université Washington de Saint-Louis)</orgName>
</affiliation>
</author>
<author>
<name sortKey="Meredith, Travis A" sort="Meredith, Travis A" uniqKey="Meredith T" first="Travis A." last="Meredith">Travis A. Meredith</name>
<affiliation wicri:level="4">
<inist:fA14 i1="01">
<s1>Barnes Retina Institute and the Department of Ophthalmology and Visual Sciences, Washington University School of Medicine</s1>
<s2>St. Louis, Missouri</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName>
<region type="state">Missouri (État)</region>
</placeName>
<orgName type="university">École de médecine (Université Washington de Saint-Louis)</orgName>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">01-0388286</idno>
<date when="2001">2001</date>
<idno type="stanalyst">PASCAL 01-0388286 INIST</idno>
<idno type="RBID">Pascal:01-0388286</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">001363</idno>
<idno type="wicri:Area/PascalFrancis/Curation">000149</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">001178</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">"Luggage-tag" suture fixation of partially dislocated intraocular lenses</title>
<author>
<name sortKey="Virata, Steven R" sort="Virata, Steven R" uniqKey="Virata S" first="Steven R." last="Virata">Steven R. Virata</name>
<affiliation wicri:level="4">
<inist:fA14 i1="01">
<s1>Barnes Retina Institute and the Department of Ophthalmology and Visual Sciences, Washington University School of Medicine</s1>
<s2>St. Louis, Missouri</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName>
<region type="state">Missouri (État)</region>
</placeName>
<orgName type="university">École de médecine (Université Washington de Saint-Louis)</orgName>
</affiliation>
</author>
<author>
<name sortKey="Holekamp, Nancy M" sort="Holekamp, Nancy M" uniqKey="Holekamp N" first="Nancy M." last="Holekamp">Nancy M. Holekamp</name>
<affiliation wicri:level="4">
<inist:fA14 i1="01">
<s1>Barnes Retina Institute and the Department of Ophthalmology and Visual Sciences, Washington University School of Medicine</s1>
<s2>St. Louis, Missouri</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName>
<region type="state">Missouri (État)</region>
</placeName>
<orgName type="university">École de médecine (Université Washington de Saint-Louis)</orgName>
</affiliation>
</author>
<author>
<name sortKey="Meredith, Travis A" sort="Meredith, Travis A" uniqKey="Meredith T" first="Travis A." last="Meredith">Travis A. Meredith</name>
<affiliation wicri:level="4">
<inist:fA14 i1="01">
<s1>Barnes Retina Institute and the Department of Ophthalmology and Visual Sciences, Washington University School of Medicine</s1>
<s2>St. Louis, Missouri</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName>
<region type="state">Missouri (État)</region>
</placeName>
<orgName type="university">École de médecine (Université Washington de Saint-Louis)</orgName>
</affiliation>
</author>
</analytic>
<series>
<title level="j" type="main">Ophthalmic surgery and lasers</title>
<title level="j" type="abbreviated">Ophthalmic surg. lasers</title>
<idno type="ISSN">1082-3069</idno>
<imprint>
<date when="2001">2001</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">Ophthalmic surgery and lasers</title>
<title level="j" type="abbreviated">Ophthalmic surg. lasers</title>
<idno type="ISSN">1082-3069</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Case study</term>
<term>Elderly</term>
<term>Eye</term>
<term>Fixation</term>
<term>Intraocular lens</term>
<term>Luxation</term>
<term>Sclera</term>
<term>Suturation</term>
<term>Technique</term>
<term>Treatment</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Lentille intraoculaire</term>
<term>Luxation</term>
<term>Fixation</term>
<term>Sclérotique</term>
<term>Suture chirurgicale</term>
<term>Technique</term>
<term>Traitement</term>
<term>Etude cas</term>
<term>Personne âgée</term>
<term>Oeil</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr">
<term>Personne âgée</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">There are many techniques for sulcus-suturing dislocated or partially dislocated intraocular lenses. Many involve passing suture or a knot around the end of the haptic before securing the suture to the sclera. However, in some patients, the tip of the dislocated haptic cannot be visualized. We describe a suturing method using vitrectomy techniques that was used in two patients when the end of the haptic could not be visualized. The technique involves passing an untied loop of double-armed suture under the haptic so that it emerges upward between the haptic and the optic. The loop of suture is regrasped from above the haptic and externalized. The free ends are passed through the loop in a manner analogous to a luggage tag, and the knot is secured. This technique may be useful in patients where the tip of the haptic cannot be visualized, or in patients requiring minimal manipulation of the intraocular lens.</div>
</front>
</TEI>
<inist>
<standard h6="B">
<pA>
<fA01 i1="01" i2="1">
<s0>1082-3069</s0>
</fA01>
<fA02 i1="01">
<s0>OSLAF2</s0>
</fA02>
<fA03 i2="1">
<s0>Ophthalmic surg. lasers</s0>
</fA03>
<fA05>
<s2>32</s2>
</fA05>
<fA06>
<s2>4</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG">
<s1>"Luggage-tag" suture fixation of partially dislocated intraocular lenses</s1>
</fA08>
<fA11 i1="01" i2="1">
<s1>VIRATA (Steven R.)</s1>
</fA11>
<fA11 i1="02" i2="1">
<s1>HOLEKAMP (Nancy M.)</s1>
</fA11>
<fA11 i1="03" i2="1">
<s1>MEREDITH (Travis A.)</s1>
</fA11>
<fA14 i1="01">
<s1>Barnes Retina Institute and the Department of Ophthalmology and Visual Sciences, Washington University School of Medicine</s1>
<s2>St. Louis, Missouri</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</fA14>
<fA20>
<s1>346-348</s1>
</fA20>
<fA21>
<s1>2001</s1>
</fA21>
<fA23 i1="01">
<s0>ENG</s0>
</fA23>
<fA43 i1="01">
<s1>INIST</s1>
<s2>14946</s2>
<s5>354000099044270160</s5>
</fA43>
<fA44>
<s0>0000</s0>
<s1>© 2001 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45>
<s0>11 ref.</s0>
</fA45>
<fA47 i1="01" i2="1">
<s0>01-0388286</s0>
</fA47>
<fA60>
<s1>P</s1>
</fA60>
<fA61>
<s0>A</s0>
</fA61>
<fA64 i1="01" i2="1">
<s0>Ophthalmic surgery and lasers</s0>
</fA64>
<fA66 i1="01">
<s0>USA</s0>
</fA66>
<fC01 i1="01" l="ENG">
<s0>There are many techniques for sulcus-suturing dislocated or partially dislocated intraocular lenses. Many involve passing suture or a knot around the end of the haptic before securing the suture to the sclera. However, in some patients, the tip of the dislocated haptic cannot be visualized. We describe a suturing method using vitrectomy techniques that was used in two patients when the end of the haptic could not be visualized. The technique involves passing an untied loop of double-armed suture under the haptic so that it emerges upward between the haptic and the optic. The loop of suture is regrasped from above the haptic and externalized. The free ends are passed through the loop in a manner analogous to a luggage tag, and the knot is secured. This technique may be useful in patients where the tip of the haptic cannot be visualized, or in patients requiring minimal manipulation of the intraocular lens.</s0>
</fC01>
<fC02 i1="01" i2="X">
<s0>002B25B</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE">
<s0>Lentille intraoculaire</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG">
<s0>Intraocular lens</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA">
<s0>Lente intraocular</s0>
<s5>01</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE">
<s0>Luxation</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG">
<s0>Luxation</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA">
<s0>Luxación</s0>
<s5>02</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE">
<s0>Fixation</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG">
<s0>Fixation</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA">
<s0>Fijación</s0>
<s5>03</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE">
<s0>Sclérotique</s0>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG">
<s0>Sclera</s0>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA">
<s0>Esclerótica</s0>
<s5>04</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE">
<s0>Suture chirurgicale</s0>
<s5>05</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG">
<s0>Suturation</s0>
<s5>05</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA">
<s0>Sutura quirúrgica</s0>
<s5>05</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE">
<s0>Technique</s0>
<s5>06</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG">
<s0>Technique</s0>
<s5>06</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA">
<s0>Técnica</s0>
<s5>06</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE">
<s0>Traitement</s0>
<s5>07</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG">
<s0>Treatment</s0>
<s5>07</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA">
<s0>Tratamiento</s0>
<s5>07</s5>
</fC03>
<fC03 i1="08" i2="X" l="FRE">
<s0>Etude cas</s0>
<s5>08</s5>
</fC03>
<fC03 i1="08" i2="X" l="ENG">
<s0>Case study</s0>
<s5>08</s5>
</fC03>
<fC03 i1="08" i2="X" l="SPA">
<s0>Estudio caso</s0>
<s5>08</s5>
</fC03>
<fC03 i1="09" i2="X" l="FRE">
<s0>Personne âgée</s0>
<s5>09</s5>
</fC03>
<fC03 i1="09" i2="X" l="ENG">
<s0>Elderly</s0>
<s5>09</s5>
</fC03>
<fC03 i1="09" i2="X" l="SPA">
<s0>Anciano</s0>
<s5>09</s5>
</fC03>
<fC03 i1="10" i2="X" l="FRE">
<s0>Oeil</s0>
<s5>10</s5>
</fC03>
<fC03 i1="10" i2="X" l="ENG">
<s0>Eye</s0>
<s5>10</s5>
</fC03>
<fC03 i1="10" i2="X" l="SPA">
<s0>Ojo</s0>
<s5>10</s5>
</fC03>
<fC07 i1="01" i2="X" l="FRE">
<s0>Homme</s0>
</fC07>
<fC07 i1="01" i2="X" l="ENG">
<s0>Human</s0>
</fC07>
<fC07 i1="01" i2="X" l="SPA">
<s0>Hombre</s0>
</fC07>
<fC07 i1="02" i2="X" l="FRE">
<s0>Chirurgie</s0>
<s5>37</s5>
</fC07>
<fC07 i1="02" i2="X" l="ENG">
<s0>Surgery</s0>
<s5>37</s5>
</fC07>
<fC07 i1="02" i2="X" l="SPA">
<s0>Cirugía</s0>
<s5>37</s5>
</fC07>
<fN21>
<s1>274</s1>
</fN21>
</pA>
</standard>
</inist>
<affiliations>
<list>
<country>
<li>États-Unis</li>
</country>
<region>
<li>Missouri (État)</li>
</region>
<orgName>
<li>École de médecine (Université Washington de Saint-Louis)</li>
</orgName>
</list>
<tree>
<country name="États-Unis">
<region name="Missouri (État)">
<name sortKey="Virata, Steven R" sort="Virata, Steven R" uniqKey="Virata S" first="Steven R." last="Virata">Steven R. Virata</name>
</region>
<name sortKey="Holekamp, Nancy M" sort="Holekamp, Nancy M" uniqKey="Holekamp N" first="Nancy M." last="Holekamp">Nancy M. Holekamp</name>
<name sortKey="Meredith, Travis A" sort="Meredith, Travis A" uniqKey="Meredith T" first="Travis A." last="Meredith">Travis A. Meredith</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PascalFrancis/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001178 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Checkpoint/biblio.hfd -nk 001178 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PascalFrancis
   |étape=   Checkpoint
   |type=    RBID
   |clé=     Pascal:01-0388286
   |texte=   "Luggage-tag" suture fixation of partially dislocated intraocular lenses
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024