Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Surgical technique for repositioning subluxated previously scleral-fixated intraocular lenses

Identifieur interne : 000C04 ( PascalFrancis/Checkpoint ); précédent : 000C03; suivant : 000C05

Surgical technique for repositioning subluxated previously scleral-fixated intraocular lenses

Auteurs : Florian N. Balta [Roumanie]

Source :

RBID : Pascal:04-0586692

Descripteurs français

English descriptors

Abstract

PURPOSE: To describe a repositioning technique of a subluxated scleral-fixated rigid intraocular lens (IOL) with haptic holes in eyes with complete or anterior vitrectomy. DESIGN: Interventional case series. METHODS: Using a two-port pars plana vitrectomy, a 10-0 polypropylene suture with the free end fixated to a haptic hole cut from another artificial IOL is passed through a paracentesis, then through the hole of the haptic luxated in the vitreous cavity. It is then reanchored at the sclera, repositioning the IOL. RESULTS: In the two eyes, visual acuity was restored to pre-subluxation levels. During 6-month follow-up, anatomic and functional results were stable, and there were no complications. CONCLUSIONS: This technique enables repositioning of a subluxated, previously sutured rigid IOL without externalization of the lens or haptics and with good results.


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

Pascal:04-0586692

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">Surgical technique for repositioning subluxated previously scleral-fixated intraocular lenses</title>
<author>
<name sortKey="Balta, Florian N" sort="Balta, Florian N" uniqKey="Balta F" first="Florian N." last="Balta">Florian N. Balta</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Department of Ophthalmology, Bucharest Eye Hospital and Clinic, Garol Davila University of Medicine and Pharmacy</s1>
<s2>Bucharest</s2>
<s3>ROM</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
<country wicri:auto="ROM">Roumanie</country>
<wicri:noRegion>Bucharest</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">04-0586692</idno>
<date when="2004">2004</date>
<idno type="stanalyst">PASCAL 04-0586692 INIST</idno>
<idno type="RBID">Pascal:04-0586692</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000F28</idno>
<idno type="wicri:Area/PascalFrancis/Curation">000581</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">000C04</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">Surgical technique for repositioning subluxated previously scleral-fixated intraocular lenses</title>
<author>
<name sortKey="Balta, Florian N" sort="Balta, Florian N" uniqKey="Balta F" first="Florian N." last="Balta">Florian N. Balta</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Department of Ophthalmology, Bucharest Eye Hospital and Clinic, Garol Davila University of Medicine and Pharmacy</s1>
<s2>Bucharest</s2>
<s3>ROM</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
<country wicri:auto="ROM">Roumanie</country>
<wicri:noRegion>Bucharest</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series>
<title level="j" type="main">American journal of ophthalmology</title>
<title level="j" type="abbreviated">Am. j. ophthalmol.</title>
<idno type="ISSN">0002-9394</idno>
<imprint>
<date when="2004">2004</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">American journal of ophthalmology</title>
<title level="j" type="abbreviated">Am. j. ophthalmol.</title>
<idno type="ISSN">0002-9394</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Intraocular lens</term>
<term>Ophthalmology</term>
<term>Sclera</term>
<term>Surgery</term>
<term>Technique</term>
<term>Treatment</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Chirurgie</term>
<term>Technique</term>
<term>Sclérotique</term>
<term>Lentille intraoculaire</term>
<term>Ophtalmologie</term>
<term>Traitement</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr">
<term>Chirurgie</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">PURPOSE: To describe a repositioning technique of a subluxated scleral-fixated rigid intraocular lens (IOL) with haptic holes in eyes with complete or anterior vitrectomy. DESIGN: Interventional case series. METHODS: Using a two-port pars plana vitrectomy, a 10-0 polypropylene suture with the free end fixated to a haptic hole cut from another artificial IOL is passed through a paracentesis, then through the hole of the haptic luxated in the vitreous cavity. It is then reanchored at the sclera, repositioning the IOL. RESULTS: In the two eyes, visual acuity was restored to pre-subluxation levels. During 6-month follow-up, anatomic and functional results were stable, and there were no complications. CONCLUSIONS: This technique enables repositioning of a subluxated, previously sutured rigid IOL without externalization of the lens or haptics and with good results.</div>
</front>
</TEI>
<inist>
<standard h6="B">
<pA>
<fA01 i1="01" i2="1">
<s0>0002-9394</s0>
</fA01>
<fA02 i1="01">
<s0>AJOPAA</s0>
</fA02>
<fA03 i2="1">
<s0>Am. j. ophthalmol.</s0>
</fA03>
<fA05>
<s2>138</s2>
</fA05>
<fA06>
<s2>4</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG">
<s1>Surgical technique for repositioning subluxated previously scleral-fixated intraocular lenses</s1>
</fA08>
<fA11 i1="01" i2="1">
<s1>BALTA (Florian N.)</s1>
</fA11>
<fA14 i1="01">
<s1>Department of Ophthalmology, Bucharest Eye Hospital and Clinic, Garol Davila University of Medicine and Pharmacy</s1>
<s2>Bucharest</s2>
<s3>ROM</s3>
<sZ>1 aut.</sZ>
</fA14>
<fA20>
<s1>676-677</s1>
</fA20>
<fA21>
<s1>2004</s1>
</fA21>
<fA23 i1="01">
<s0>ENG</s0>
</fA23>
<fA43 i1="01">
<s1>INIST</s1>
<s2>2012</s2>
<s5>354000122483250370</s5>
</fA43>
<fA44>
<s0>0000</s0>
<s1>© 2004 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45>
<s0>5 ref.</s0>
</fA45>
<fA47 i1="01" i2="1">
<s0>04-0586692</s0>
</fA47>
<fA60>
<s1>P</s1>
<s3>CC</s3>
</fA60>
<fA61>
<s0>A</s0>
</fA61>
<fA64 i1="01" i2="1">
<s0>American journal of ophthalmology</s0>
</fA64>
<fA66 i1="01">
<s0>USA</s0>
</fA66>
<fC01 i1="01" l="ENG">
<s0>PURPOSE: To describe a repositioning technique of a subluxated scleral-fixated rigid intraocular lens (IOL) with haptic holes in eyes with complete or anterior vitrectomy. DESIGN: Interventional case series. METHODS: Using a two-port pars plana vitrectomy, a 10-0 polypropylene suture with the free end fixated to a haptic hole cut from another artificial IOL is passed through a paracentesis, then through the hole of the haptic luxated in the vitreous cavity. It is then reanchored at the sclera, repositioning the IOL. RESULTS: In the two eyes, visual acuity was restored to pre-subluxation levels. During 6-month follow-up, anatomic and functional results were stable, and there were no complications. CONCLUSIONS: This technique enables repositioning of a subluxated, previously sutured rigid IOL without externalization of the lens or haptics and with good results.</s0>
</fC01>
<fC02 i1="01" i2="X">
<s0>002B25B</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE">
<s0>Chirurgie</s0>
<s5>02</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG">
<s0>Surgery</s0>
<s5>02</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA">
<s0>Cirugía</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE">
<s0>Technique</s0>
<s5>03</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG">
<s0>Technique</s0>
<s5>03</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA">
<s0>Técnica</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE">
<s0>Sclérotique</s0>
<s5>05</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG">
<s0>Sclera</s0>
<s5>05</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA">
<s0>Esclerótica</s0>
<s5>05</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE">
<s0>Lentille intraoculaire</s0>
<s5>06</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG">
<s0>Intraocular lens</s0>
<s5>06</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA">
<s0>Lente intraocular</s0>
<s5>06</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE">
<s0>Ophtalmologie</s0>
<s5>08</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG">
<s0>Ophthalmology</s0>
<s5>08</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA">
<s0>Oftalmología</s0>
<s5>08</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE">
<s0>Traitement</s0>
<s5>25</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG">
<s0>Treatment</s0>
<s5>25</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA">
<s0>Tratamiento</s0>
<s5>25</s5>
</fC03>
<fN21>
<s1>334</s1>
</fN21>
<fN44 i1="01">
<s1>OTO</s1>
</fN44>
<fN82>
<s1>OTO</s1>
</fN82>
</pA>
</standard>
</inist>
<affiliations>
<list>
<country>
<li>Roumanie</li>
</country>
</list>
<tree>
<country name="Roumanie">
<noRegion>
<name sortKey="Balta, Florian N" sort="Balta, Florian N" uniqKey="Balta F" first="Florian N." last="Balta">Florian N. Balta</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PascalFrancis/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000C04 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Checkpoint/biblio.hfd -nk 000C04 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PascalFrancis
   |étape=   Checkpoint
   |type=    RBID
   |clé=     Pascal:04-0586692
   |texte=   Surgical technique for repositioning subluxated previously scleral-fixated intraocular lenses
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024