[Anterior chamber intraocular lenses for aphakia correction].

Identifieur interne : 002E62 ( Ncbi/Merge ); précédent : 002E61; suivant : 002E63

[Anterior chamber intraocular lenses for aphakia correction].

Auteurs : T. Kohnen [Allemagne] ; F H Hengerer

Source :

RBID : pubmed:24706252

English descriptors

Abstract

The intraocular correction of aphakia in the anterior chamber currently consists of two options: an angle supported intraocular lens (IOL, Kelman Multiflex) and an iris fixated IOL (Artisan/Verisyse). The angle supported IOL is fixated with four haptic points in the anterior chamber and the iris fixated IOL is enclavated to the anterior iris surface. Acceptable results of both IOLs are reported in the literature; however both IOLs show some long-term complications in some eyes. Alternatives to these anterior chamber IOLs to correct aphakia are the retropupillary fixated Artisan and sclera fixated IOLs.

DOI: 10.1007/s00347-013-2853-7
PubMed: 24706252

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:24706252

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">[Anterior chamber intraocular lenses for aphakia correction].</title>
<author>
<name sortKey="Kohnen, T" sort="Kohnen, T" uniqKey="Kohnen T" first="T" last="Kohnen">T. Kohnen</name>
<affiliation wicri:level="1">
<nlm:affiliation>Klinik für Augenheilkunde, Klinikum der Goethe-Universität, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Deutschland, kohnen@em.uni-frankfurt.de.</nlm:affiliation>
<country wicri:rule="url">Allemagne</country>
<wicri:regionArea>Klinik für Augenheilkunde, Klinikum der Goethe-Universität, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Deutschland</wicri:regionArea>
<wicri:noRegion>Deutschland</wicri:noRegion>
<wicri:noRegion>Deutschland</wicri:noRegion>
<wicri:noRegion>Deutschland</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Hengerer, F H" sort="Hengerer, F H" uniqKey="Hengerer F" first="F H" last="Hengerer">F H Hengerer</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="doi">10.1007/s00347-013-2853-7</idno>
<idno type="RBID">pubmed:24706252</idno>
<idno type="pmid">24706252</idno>
<idno type="wicri:Area/PubMed/Corpus">000700</idno>
<idno type="wicri:Area/PubMed/Curation">000700</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000466</idno>
<idno type="wicri:Area/Ncbi/Merge">002E62</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">[Anterior chamber intraocular lenses for aphakia correction].</title>
<author>
<name sortKey="Kohnen, T" sort="Kohnen, T" uniqKey="Kohnen T" first="T" last="Kohnen">T. Kohnen</name>
<affiliation wicri:level="1">
<nlm:affiliation>Klinik für Augenheilkunde, Klinikum der Goethe-Universität, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Deutschland, kohnen@em.uni-frankfurt.de.</nlm:affiliation>
<country wicri:rule="url">Allemagne</country>
<wicri:regionArea>Klinik für Augenheilkunde, Klinikum der Goethe-Universität, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Deutschland</wicri:regionArea>
<wicri:noRegion>Deutschland</wicri:noRegion>
<wicri:noRegion>Deutschland</wicri:noRegion>
<wicri:noRegion>Deutschland</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Hengerer, F H" sort="Hengerer, F H" uniqKey="Hengerer F" first="F H" last="Hengerer">F H Hengerer</name>
</author>
</analytic>
<series>
<title level="j">Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft</title>
<idno type="eISSN">1433-0423</idno>
<imprint>
<date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Anterior Chamber (surgery)</term>
<term>Aphakia, Postcataract (surgery)</term>
<term>Humans</term>
<term>Iris (surgery)</term>
<term>Lens Implantation, Intraocular (instrumentation)</term>
<term>Lens Implantation, Intraocular (methods)</term>
<term>Lenses, Intraocular</term>
<term>Reoperation (instrumentation)</term>
<term>Reoperation (methods)</term>
<term>Suture Anchors</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Lens Implantation, Intraocular</term>
<term>Reoperation</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Lens Implantation, Intraocular</term>
<term>Reoperation</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Anterior Chamber</term>
<term>Aphakia, Postcataract</term>
<term>Iris</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Suture Anchors</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The intraocular correction of aphakia in the anterior chamber currently consists of two options: an angle supported intraocular lens (IOL, Kelman Multiflex) and an iris fixated IOL (Artisan/Verisyse). The angle supported IOL is fixated with four haptic points in the anterior chamber and the iris fixated IOL is enclavated to the anterior iris surface. Acceptable results of both IOLs are reported in the literature; however both IOLs show some long-term complications in some eyes. Alternatives to these anterior chamber IOLs to correct aphakia are the retropupillary fixated Artisan and sclera fixated IOLs.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">24706252</PMID>
<DateCreated>
<Year>2014</Year>
<Month>04</Month>
<Day>23</Day>
</DateCreated>
<DateCompleted>
<Year>2015</Year>
<Month>04</Month>
<Day>13</Day>
</DateCompleted>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1433-0423</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>111</Volume>
<Issue>4</Issue>
<PubDate>
<Year>2014</Year>
<Month>Apr</Month>
</PubDate>
</JournalIssue>
<Title>Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft</Title>
<ISOAbbreviation>Ophthalmologe</ISOAbbreviation>
</Journal>
<ArticleTitle>[Anterior chamber intraocular lenses for aphakia correction].</ArticleTitle>
<Pagination>
<MedlinePgn>310-4</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1007/s00347-013-2853-7</ELocationID>
<Abstract>
<AbstractText>The intraocular correction of aphakia in the anterior chamber currently consists of two options: an angle supported intraocular lens (IOL, Kelman Multiflex) and an iris fixated IOL (Artisan/Verisyse). The angle supported IOL is fixated with four haptic points in the anterior chamber and the iris fixated IOL is enclavated to the anterior iris surface. Acceptable results of both IOLs are reported in the literature; however both IOLs show some long-term complications in some eyes. Alternatives to these anterior chamber IOLs to correct aphakia are the retropupillary fixated Artisan and sclera fixated IOLs.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Kohnen</LastName>
<ForeName>T</ForeName>
<Initials>T</Initials>
<AffiliationInfo>
<Affiliation>Klinik für Augenheilkunde, Klinikum der Goethe-Universität, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Deutschland, kohnen@em.uni-frankfurt.de.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Hengerer</LastName>
<ForeName>F H</ForeName>
<Initials>FH</Initials>
</Author>
</AuthorList>
<Language>ger</Language>
<PublicationTypeList>
<PublicationType UI="D004740">English Abstract</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<VernacularTitle>Vorderkammerintraokularlinsen bei Aphakie.</VernacularTitle>
</Article>
<MedlineJournalInfo>
<Country>Germany</Country>
<MedlineTA>Ophthalmologe</MedlineTA>
<NlmUniqueID>9206148</NlmUniqueID>
<ISSNLinking>0941-293X</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000867">Anterior Chamber</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D001036">Aphakia, Postcataract</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007498">Iris</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012086">Reoperation</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000295">instrumentation</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D053441">Suture Anchors</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2014</Year>
<Month>4</Month>
<Day>8</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2014</Year>
<Month>4</Month>
<Day>8</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>4</Month>
<Day>14</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="doi">10.1007/s00347-013-2853-7</ArticleId>
<ArticleId IdType="pubmed">24706252</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Allemagne</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Hengerer, F H" sort="Hengerer, F H" uniqKey="Hengerer F" first="F H" last="Hengerer">F H Hengerer</name>
</noCountry>
<country name="Allemagne">
<noRegion>
<name sortKey="Kohnen, T" sort="Kohnen, T" uniqKey="Kohnen T" first="T" last="Kohnen">T. Kohnen</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002E62 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 002E62 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:24706252
   |texte=   [Anterior chamber intraocular lenses for aphakia correction].
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:24706252" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024