Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

[Three-dimensional ultrasound biomicroscopic examinations for haptic differentiation of potentially accommodative intraocular lenses].

Identifieur interne : 000627 ( Ncbi/Merge ); précédent : 000626; suivant : 000628

[Three-dimensional ultrasound biomicroscopic examinations for haptic differentiation of potentially accommodative intraocular lenses].

Auteurs : O. Stachs [Allemagne] ; H. Schneider ; J. Stave ; R. Beck ; R F Guthoff

Source :

RBID : pubmed:15503052

English descriptors

Abstract

The principal ability of potentially accommodative IOLs is based on an axial shift of the IOL optics induced by the ciliary body action in interaction with a reversible change in haptic angulation. The aim of this study was to investigate the accommodative performance of this new IOL generation.

DOI: 10.1007/s00347-004-1122-1
PubMed: 15503052

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:15503052

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">[Three-dimensional ultrasound biomicroscopic examinations for haptic differentiation of potentially accommodative intraocular lenses].</title>
<author>
<name sortKey="Stachs, O" sort="Stachs, O" uniqKey="Stachs O" first="O" last="Stachs">O. Stachs</name>
<affiliation wicri:level="1">
<nlm:affiliation>Augenklinik, Universität Rostock. oliver.stachs@med.uni-rostock.de</nlm:affiliation>
<country wicri:rule="url">Allemagne</country>
</affiliation>
</author>
<author>
<name sortKey="Schneider, H" sort="Schneider, H" uniqKey="Schneider H" first="H" last="Schneider">H. Schneider</name>
</author>
<author>
<name sortKey="Stave, J" sort="Stave, J" uniqKey="Stave J" first="J" last="Stave">J. Stave</name>
</author>
<author>
<name sortKey="Beck, R" sort="Beck, R" uniqKey="Beck R" first="R" last="Beck">R. Beck</name>
</author>
<author>
<name sortKey="Guthoff, R F" sort="Guthoff, R F" uniqKey="Guthoff R" first="R F" last="Guthoff">R F Guthoff</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2005">2005</date>
<idno type="doi">10.1007/s00347-004-1122-1</idno>
<idno type="RBID">pubmed:15503052</idno>
<idno type="pmid">15503052</idno>
<idno type="wicri:Area/PubMed/Corpus">001A45</idno>
<idno type="wicri:Area/PubMed/Curation">001A45</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001643</idno>
<idno type="wicri:Area/Ncbi/Merge">000627</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">[Three-dimensional ultrasound biomicroscopic examinations for haptic differentiation of potentially accommodative intraocular lenses].</title>
<author>
<name sortKey="Stachs, O" sort="Stachs, O" uniqKey="Stachs O" first="O" last="Stachs">O. Stachs</name>
<affiliation wicri:level="1">
<nlm:affiliation>Augenklinik, Universität Rostock. oliver.stachs@med.uni-rostock.de</nlm:affiliation>
<country wicri:rule="url">Allemagne</country>
</affiliation>
</author>
<author>
<name sortKey="Schneider, H" sort="Schneider, H" uniqKey="Schneider H" first="H" last="Schneider">H. Schneider</name>
</author>
<author>
<name sortKey="Stave, J" sort="Stave, J" uniqKey="Stave J" first="J" last="Stave">J. Stave</name>
</author>
<author>
<name sortKey="Beck, R" sort="Beck, R" uniqKey="Beck R" first="R" last="Beck">R. Beck</name>
</author>
<author>
<name sortKey="Guthoff, R F" sort="Guthoff, R F" uniqKey="Guthoff R" first="R F" last="Guthoff">R F Guthoff</name>
</author>
</analytic>
<series>
<title level="j">Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft</title>
<idno type="ISSN">0941-293X</idno>
<imprint>
<date when="2005" type="published">2005</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Accommodation, Ocular (physiology)</term>
<term>Aged</term>
<term>Equipment Failure Analysis</term>
<term>Female</term>
<term>Humans</term>
<term>Image Enhancement (instrumentation)</term>
<term>Image Processing, Computer-Assisted (instrumentation)</term>
<term>Imaging, Three-Dimensional (instrumentation)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Microscopy, Acoustic (instrumentation)</term>
<term>Ophthalmoscopes</term>
<term>Optics and Photonics</term>
<term>Phantoms, Imaging</term>
<term>Prosthesis Design</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Image Enhancement</term>
<term>Image Processing, Computer-Assisted</term>
<term>Imaging, Three-Dimensional</term>
<term>Microscopy, Acoustic</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Accommodation, Ocular</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Equipment Failure Analysis</term>
<term>Female</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Ophthalmoscopes</term>
<term>Optics and Photonics</term>
<term>Phantoms, Imaging</term>
<term>Prosthesis Design</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The principal ability of potentially accommodative IOLs is based on an axial shift of the IOL optics induced by the ciliary body action in interaction with a reversible change in haptic angulation. The aim of this study was to investigate the accommodative performance of this new IOL generation.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">15503052</PMID>
<DateCreated>
<Year>2005</Year>
<Month>03</Month>
<Day>10</Day>
</DateCreated>
<DateCompleted>
<Year>2005</Year>
<Month>07</Month>
<Day>19</Day>
</DateCompleted>
<DateRevised>
<Year>2008</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0941-293X</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>102</Volume>
<Issue>3</Issue>
<PubDate>
<Year>2005</Year>
<Month>Mar</Month>
</PubDate>
</JournalIssue>
<Title>Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft</Title>
<ISOAbbreviation>Ophthalmologe</ISOAbbreviation>
</Journal>
<ArticleTitle>[Three-dimensional ultrasound biomicroscopic examinations for haptic differentiation of potentially accommodative intraocular lenses].</ArticleTitle>
<Pagination>
<MedlinePgn>265-71</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">The principal ability of potentially accommodative IOLs is based on an axial shift of the IOL optics induced by the ciliary body action in interaction with a reversible change in haptic angulation. The aim of this study was to investigate the accommodative performance of this new IOL generation.</AbstractText>
<AbstractText Label="METHOD" NlmCategory="METHODS">The authors have designed a test device to study IOL performance experimentally. These results were extrapolated to the in vivo situation in patients with accommodative implants.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The 3D high-resolution presentation of the anterior segment of the eye allows a separation of the IOL haptic elements. In vitro and in the selected in vivo cases a change in haptic angulation <10 degrees in combination with a maximal IOL shift of 0.5 mm was found.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">The simulation model used in combination with 3D ultrasound biomicroscopy provides information about the potential of accommodative IOL designs. Conclusions corresponding to changes in haptic angulation during accommodation can be drawn and applied to the in vivo situation.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Stachs</LastName>
<ForeName>O</ForeName>
<Initials>O</Initials>
<AffiliationInfo>
<Affiliation>Augenklinik, Universität Rostock. oliver.stachs@med.uni-rostock.de</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Schneider</LastName>
<ForeName>H</ForeName>
<Initials>H</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Stave</LastName>
<ForeName>J</ForeName>
<Initials>J</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Beck</LastName>
<ForeName>R</ForeName>
<Initials>R</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Guthoff</LastName>
<ForeName>R F</ForeName>
<Initials>RF</Initials>
</Author>
</AuthorList>
<Language>ger</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D004740">English Abstract</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<VernacularTitle>3D-ultraschallbiomikroskopische Untersuchungen zur Differenzierung der Haptiken von potenziell akkommodationsfähigen Intraokularlinsen.</VernacularTitle>
</Article>
<MedlineJournalInfo>
<Country>Germany</Country>
<MedlineTA>Ophthalmologe</MedlineTA>
<NlmUniqueID>9206148</NlmUniqueID>
<ISSNLinking>0941-293X</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000065">Accommodation, Ocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000502">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019544">Equipment Failure Analysis</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007089">Image Enhancement</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007091">Image Processing, Computer-Assisted</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D021621">Imaging, Three-Dimensional</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D033401">Microscopy, Acoustic</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D019721">Ophthalmoscopes</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D055095">Optics and Photonics</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019047">Phantoms, Imaging</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2004</Year>
<Month>10</Month>
<Day>27</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2005</Year>
<Month>7</Month>
<Day>20</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2004</Year>
<Month>10</Month>
<Day>27</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="doi">10.1007/s00347-004-1122-1</ArticleId>
<ArticleId IdType="pubmed">15503052</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Allemagne</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Beck, R" sort="Beck, R" uniqKey="Beck R" first="R" last="Beck">R. Beck</name>
<name sortKey="Guthoff, R F" sort="Guthoff, R F" uniqKey="Guthoff R" first="R F" last="Guthoff">R F Guthoff</name>
<name sortKey="Schneider, H" sort="Schneider, H" uniqKey="Schneider H" first="H" last="Schneider">H. Schneider</name>
<name sortKey="Stave, J" sort="Stave, J" uniqKey="Stave J" first="J" last="Stave">J. Stave</name>
</noCountry>
<country name="Allemagne">
<noRegion>
<name sortKey="Stachs, O" sort="Stachs, O" uniqKey="Stachs O" first="O" last="Stachs">O. Stachs</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000627 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 000627 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:15503052
   |texte=   [Three-dimensional ultrasound biomicroscopic examinations for haptic differentiation of potentially accommodative intraocular lenses].
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:15503052" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024