Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Non-colocated Kinesthetic Display Limits Compliance Discrimination in the Absence of Terminal Force Cues.

Identifieur interne : 004185 ( Ncbi/Curation ); précédent : 004184; suivant : 004186

Non-colocated Kinesthetic Display Limits Compliance Discrimination in the Absence of Terminal Force Cues.

Auteurs : Jeremy Brown ; Mackenzie Shelley ; Duane Gardner ; Emmanuel A. Gansallo ; R B Gillespie

Source :

RBID : pubmed:27101616

Abstract

An important goal of haptic display is to make available the action/reaction relationships that define interactions between the body and the physical world. While in physical world interactions reaction cues invariably impinge on the same part of the body involved in action (reaction and action are colocated), a haptic interface is quite capable of rendering feedback to a separate body part than that used for producing exploratory actions (non-colocated action and reaction). This most commonly occurs with the use of vibrotactile display, in which a cutaneous cue has been substituted for a kinesthetic cue (a kind of sensory substitution). In this paper we investigate whether non-colocated force and displacement cues degrade the perception of compliance. Using a custom non-colocated kinesthetic display in which one hand controls displacement and the other senses force, we ask participants to discriminate between two virtual springs with matched terminal force and adjustable non-linearity. An additional condition includes one hand controlling displacement while the other senses force encoded in a vibrotactile cue. Results show that when the terminal force cue is unavailable, and even when sensory substitution is not involved, non-colocated kinesthetic displays degrade compliance discrimination relative to colocated kinesthetic displays. Compliance discrimination is also degraded with vibrotactile display of force. These findings suggest that non-colocated kinesthetic displays and likewise cutaneous sensory substitution displays should be avoided when discrimination of compliance is necessary for task success.

DOI: 10.1109/TOH.2016.2554120
PubMed: 27101616

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:27101616

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Non-colocated Kinesthetic Display Limits Compliance Discrimination in the Absence of Terminal Force Cues.</title>
<author>
<name sortKey="Brown, Jeremy" sort="Brown, Jeremy" uniqKey="Brown J" first="Jeremy" last="Brown">Jeremy Brown</name>
</author>
<author>
<name sortKey="Shelley, Mackenzie" sort="Shelley, Mackenzie" uniqKey="Shelley M" first="Mackenzie" last="Shelley">Mackenzie Shelley</name>
</author>
<author>
<name sortKey="Gardner, Duane" sort="Gardner, Duane" uniqKey="Gardner D" first="Duane" last="Gardner">Duane Gardner</name>
</author>
<author>
<name sortKey="Gansallo, Emmanuel A" sort="Gansallo, Emmanuel A" uniqKey="Gansallo E" first="Emmanuel A" last="Gansallo">Emmanuel A. Gansallo</name>
</author>
<author>
<name sortKey="Gillespie, R B" sort="Gillespie, R B" uniqKey="Gillespie R" first="R B" last="Gillespie">R B Gillespie</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2016">2016</date>
<idno type="doi">10.1109/TOH.2016.2554120</idno>
<idno type="RBID">pubmed:27101616</idno>
<idno type="pmid">27101616</idno>
<idno type="wicri:Area/PubMed/Corpus">000034</idno>
<idno type="wicri:Area/PubMed/Curation">000034</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000069</idno>
<idno type="wicri:Area/Ncbi/Merge">004185</idno>
<idno type="wicri:Area/Ncbi/Curation">004185</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Non-colocated Kinesthetic Display Limits Compliance Discrimination in the Absence of Terminal Force Cues.</title>
<author>
<name sortKey="Brown, Jeremy" sort="Brown, Jeremy" uniqKey="Brown J" first="Jeremy" last="Brown">Jeremy Brown</name>
</author>
<author>
<name sortKey="Shelley, Mackenzie" sort="Shelley, Mackenzie" uniqKey="Shelley M" first="Mackenzie" last="Shelley">Mackenzie Shelley</name>
</author>
<author>
<name sortKey="Gardner, Duane" sort="Gardner, Duane" uniqKey="Gardner D" first="Duane" last="Gardner">Duane Gardner</name>
</author>
<author>
<name sortKey="Gansallo, Emmanuel A" sort="Gansallo, Emmanuel A" uniqKey="Gansallo E" first="Emmanuel A" last="Gansallo">Emmanuel A. Gansallo</name>
</author>
<author>
<name sortKey="Gillespie, R B" sort="Gillespie, R B" uniqKey="Gillespie R" first="R B" last="Gillespie">R B Gillespie</name>
</author>
</analytic>
<series>
<title level="j">IEEE transactions on haptics</title>
<idno type="eISSN">2329-4051</idno>
<imprint>
<date when="2016" type="published">2016</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">An important goal of haptic display is to make available the action/reaction relationships that define interactions between the body and the physical world. While in physical world interactions reaction cues invariably impinge on the same part of the body involved in action (reaction and action are colocated), a haptic interface is quite capable of rendering feedback to a separate body part than that used for producing exploratory actions (non-colocated action and reaction). This most commonly occurs with the use of vibrotactile display, in which a cutaneous cue has been substituted for a kinesthetic cue (a kind of sensory substitution). In this paper we investigate whether non-colocated force and displacement cues degrade the perception of compliance. Using a custom non-colocated kinesthetic display in which one hand controls displacement and the other senses force, we ask participants to discriminate between two virtual springs with matched terminal force and adjustable non-linearity. An additional condition includes one hand controlling displacement while the other senses force encoded in a vibrotactile cue. Results show that when the terminal force cue is unavailable, and even when sensory substitution is not involved, non-colocated kinesthetic displays degrade compliance discrimination relative to colocated kinesthetic displays. Compliance discrimination is also degraded with vibrotactile display of force. These findings suggest that non-colocated kinesthetic displays and likewise cutaneous sensory substitution displays should be avoided when discrimination of compliance is necessary for task success.</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004185 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd -nk 004185 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:27101616
   |texte=   Non-colocated Kinesthetic Display Limits Compliance Discrimination in the Absence of Terminal Force Cues.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/RBID.i   -Sk "pubmed:27101616" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024