Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches
Identifieur interne : 001945 ( Ncbi/Checkpoint ); précédent : 001944; suivant : 001946Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches
Auteurs : Sang-Eun Song ; Nathan B. Cho ; Gregory Fischer ; Nobuhito Hata ; Clare Tempany ; Gabor Fichtinger ; Iulian IordachitaSource :
- IEEE International Conference on Robotics and Automation : ICRA : [proceedings] IEEE International Conference on Robotics and Automation [ 2152-4092 ] ; 2010.
Abstract
Magnetic Resonance Imaging (MRI) guided prostate biopsy and brachytherapy has been introduced in order to enhance the cancer detection and treatment. For the accurate needle positioning, a number of robotic assistants have been developed. However, problems exist due to the strong magnetic field and limited workspace. Pneumatically actuated robots have shown the minimum distraction in the environment but the confined workspace limits optimal robot design and thus controllability is often poor. To overcome the problem, a simple external damping mechanism using timing belts was sought and a 1-DOF mechanism test result indicated sufficient positioning accuracy. Based on the damping mechanism and modular system design approach, a new workspace-optimized 4-DOF parallel robot was developed for the MRI-guided prostate biopsy and brachytherapy. A preliminary evaluation of the robot was conducted using previously developed pneumatic controller and satisfying results were obtained.
Url:
DOI: 10.1109/ROBOT.2010.5509710
PubMed: 21399734
PubMed Central: 3051168
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Pmc, to step Corpus: 000F51
- to stream Pmc, to step Curation: 000F51
- to stream Pmc, to step Checkpoint: 001F17
- to stream Ncbi, to step Merge: 001945
- to stream Ncbi, to step Curation: 001945
Links to Exploration step
PMC:3051168Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches</title>
<author><name sortKey="Song, Sang Eun" sort="Song, Sang Eun" uniqKey="Song S" first="Sang-Eun" last="Song">Sang-Eun Song</name>
</author>
<author><name sortKey="Cho, Nathan B" sort="Cho, Nathan B" uniqKey="Cho N" first="Nathan B." last="Cho">Nathan B. Cho</name>
</author>
<author><name sortKey="Fischer, Gregory" sort="Fischer, Gregory" uniqKey="Fischer G" first="Gregory" last="Fischer">Gregory Fischer</name>
</author>
<author><name sortKey="Hata, Nobuhito" sort="Hata, Nobuhito" uniqKey="Hata N" first="Nobuhito" last="Hata">Nobuhito Hata</name>
</author>
<author><name sortKey="Tempany, Clare" sort="Tempany, Clare" uniqKey="Tempany C" first="Clare" last="Tempany">Clare Tempany</name>
</author>
<author><name sortKey="Fichtinger, Gabor" sort="Fichtinger, Gabor" uniqKey="Fichtinger G" first="Gabor" last="Fichtinger">Gabor Fichtinger</name>
</author>
<author><name sortKey="Iordachita, Iulian" sort="Iordachita, Iulian" uniqKey="Iordachita I" first="Iulian" last="Iordachita">Iulian Iordachita</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PMC</idno>
<idno type="pmid">21399734</idno>
<idno type="pmc">3051168</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3051168</idno>
<idno type="RBID">PMC:3051168</idno>
<idno type="doi">10.1109/ROBOT.2010.5509710</idno>
<date when="2010">2010</date>
<idno type="wicri:Area/Pmc/Corpus">000F51</idno>
<idno type="wicri:Area/Pmc/Curation">000F51</idno>
<idno type="wicri:Area/Pmc/Checkpoint">001F17</idno>
<idno type="wicri:Area/Ncbi/Merge">001945</idno>
<idno type="wicri:Area/Ncbi/Curation">001945</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">001945</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a" type="main">Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches</title>
<author><name sortKey="Song, Sang Eun" sort="Song, Sang Eun" uniqKey="Song S" first="Sang-Eun" last="Song">Sang-Eun Song</name>
</author>
<author><name sortKey="Cho, Nathan B" sort="Cho, Nathan B" uniqKey="Cho N" first="Nathan B." last="Cho">Nathan B. Cho</name>
</author>
<author><name sortKey="Fischer, Gregory" sort="Fischer, Gregory" uniqKey="Fischer G" first="Gregory" last="Fischer">Gregory Fischer</name>
</author>
<author><name sortKey="Hata, Nobuhito" sort="Hata, Nobuhito" uniqKey="Hata N" first="Nobuhito" last="Hata">Nobuhito Hata</name>
</author>
<author><name sortKey="Tempany, Clare" sort="Tempany, Clare" uniqKey="Tempany C" first="Clare" last="Tempany">Clare Tempany</name>
</author>
<author><name sortKey="Fichtinger, Gabor" sort="Fichtinger, Gabor" uniqKey="Fichtinger G" first="Gabor" last="Fichtinger">Gabor Fichtinger</name>
</author>
<author><name sortKey="Iordachita, Iulian" sort="Iordachita, Iulian" uniqKey="Iordachita I" first="Iulian" last="Iordachita">Iulian Iordachita</name>
</author>
</analytic>
<series><title level="j">IEEE International Conference on Robotics and Automation : ICRA : [proceedings] IEEE International Conference on Robotics and Automation</title>
<idno type="ISSN">2152-4092</idno>
<imprint><date when="2010">2010</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en"><p id="P1">Magnetic Resonance Imaging (MRI) guided prostate biopsy and brachytherapy has been introduced in order to enhance the cancer detection and treatment. For the accurate needle positioning, a number of robotic assistants have been developed. However, problems exist due to the strong magnetic field and limited workspace. Pneumatically actuated robots have shown the minimum distraction in the environment but the confined workspace limits optimal robot design and thus controllability is often poor. To overcome the problem, a simple external damping mechanism using timing belts was sought and a 1-DOF mechanism test result indicated sufficient positioning accuracy. Based on the damping mechanism and modular system design approach, a new workspace-optimized 4-DOF parallel robot was developed for the MRI-guided prostate biopsy and brachytherapy. A preliminary evaluation of the robot was conducted using previously developed pneumatic controller and satisfying results were obtained.</p>
</div>
</front>
</TEI>
<affiliations><list></list>
<tree><noCountry><name sortKey="Cho, Nathan B" sort="Cho, Nathan B" uniqKey="Cho N" first="Nathan B." last="Cho">Nathan B. Cho</name>
<name sortKey="Fichtinger, Gabor" sort="Fichtinger, Gabor" uniqKey="Fichtinger G" first="Gabor" last="Fichtinger">Gabor Fichtinger</name>
<name sortKey="Fischer, Gregory" sort="Fischer, Gregory" uniqKey="Fischer G" first="Gregory" last="Fischer">Gregory Fischer</name>
<name sortKey="Hata, Nobuhito" sort="Hata, Nobuhito" uniqKey="Hata N" first="Nobuhito" last="Hata">Nobuhito Hata</name>
<name sortKey="Iordachita, Iulian" sort="Iordachita, Iulian" uniqKey="Iordachita I" first="Iulian" last="Iordachita">Iulian Iordachita</name>
<name sortKey="Song, Sang Eun" sort="Song, Sang Eun" uniqKey="Song S" first="Sang-Eun" last="Song">Sang-Eun Song</name>
<name sortKey="Tempany, Clare" sort="Tempany, Clare" uniqKey="Tempany C" first="Clare" last="Tempany">Clare Tempany</name>
</noCountry>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001945 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Checkpoint/biblio.hfd -nk 001945 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Ncbi |étape= Checkpoint |type= RBID |clé= PMC:3051168 |texte= Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Checkpoint/RBID.i -Sk "pubmed:21399734" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Checkpoint/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |