Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Comparison of the induced astigmatism after temporal clear corneal tunnel incisions of different sizes

Identifieur interne : 009A86 ( Main/Merge ); précédent : 009A85; suivant : 009A87

Comparison of the induced astigmatism after temporal clear corneal tunnel incisions of different sizes

Auteurs : Thomas Kohnen ; Burkhard Dick ; Karl W. Jacobi

Source :

RBID : ISTEX:2DCB1BB2B06EF3199284679C7BB70BC2E43BB43C

English descriptors

Abstract

A prospective, randomized study compared the surgically induced astigmatism after 3.5 mm, 4.0 mm, and 5.0 mm temporal corneal tunnel incisions over six months. We studied 60 eyes of 60 patients who had phacoemulsification through a two-step clear corneal tunnel incision and implantation of one of three posterior chamber intraocular lenses (IOLs). Patients were divided into three groups of 20 each: Group A, cartridge injection of a foldable plate-haptic silicone IOL through a 3.5 mm self-sealing incision; Group B, cartridge injection of a disc silicone IOL through a 4.0 mm self-sealing incision; Group C, 5.0 mm optic poly(methyl methacrylate) IOL through a 5.0 mm incision with one radial suture. Corneal topography data were obtained using a computerized videokeratographic analysis system preoperatively and one week and six months postoperatively. Vector analysis was performed to calculate the surgically induced astigmatism. After the first postoperative week, mean induced astigmatism was 0.63 diopters (D) (±0.41) in Group A, 0.64 D (±0.35) in Group B, and 0.91 D (±0.77) in Group C. After six months, it was 0.37 D (±0.14) in Group A, 0.56 D (±0.34) in Group B, and 0.70 D (±0.50) in Group C. Surgically induced astigmatism was significantly lower in Group A than in Group B (P < .05) and Group C (P < .005) after six months. Vector analysis demonstrated that temporal corneal tunnel incisions induced clinically minimal astigmatism over six months postoperatively depending on incision size.

Url:
DOI: 10.1016/S0886-3350(13)80532-9

Links toward previous steps (curation, corpus...)


Links to Exploration step

ISTEX:2DCB1BB2B06EF3199284679C7BB70BC2E43BB43C

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Comparison of the induced astigmatism after temporal clear corneal tunnel incisions of different sizes</title>
<author>
<name sortKey="Kohnen, Thomas" sort="Kohnen, Thomas" uniqKey="Kohnen T" first="Thomas" last="Kohnen">Thomas Kohnen</name>
</author>
<author>
<name sortKey="Dick, Burkhard" sort="Dick, Burkhard" uniqKey="Dick B" first="Burkhard" last="Dick">Burkhard Dick</name>
</author>
<author>
<name sortKey="Jacobi, Karl W" sort="Jacobi, Karl W" uniqKey="Jacobi K" first="Karl W." last="Jacobi">Karl W. Jacobi</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:2DCB1BB2B06EF3199284679C7BB70BC2E43BB43C</idno>
<date when="1995" year="1995">1995</date>
<idno type="doi">10.1016/S0886-3350(13)80532-9</idno>
<idno type="url">https://api.istex.fr/document/2DCB1BB2B06EF3199284679C7BB70BC2E43BB43C/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000348</idno>
<idno type="wicri:Area/Istex/Curation">000348</idno>
<idno type="wicri:Area/Istex/Checkpoint">004164</idno>
<idno type="wicri:doubleKey">0886-3350:1995:Kohnen T:comparison:of:the</idno>
<idno type="wicri:Area/Main/Merge">009A86</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Comparison of the induced astigmatism after temporal clear corneal tunnel incisions of different sizes</title>
<author>
<name sortKey="Kohnen, Thomas" sort="Kohnen, Thomas" uniqKey="Kohnen T" first="Thomas" last="Kohnen">Thomas Kohnen</name>
<affiliation>
<wicri:noCountry code="subField">University of GiessenGermany</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Dick, Burkhard" sort="Dick, Burkhard" uniqKey="Dick B" first="Burkhard" last="Dick">Burkhard Dick</name>
<affiliation>
<wicri:noCountry code="subField">University of GiessenGermany</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Jacobi, Karl W" sort="Jacobi, Karl W" uniqKey="Jacobi K" first="Karl W." last="Jacobi">Karl W. Jacobi</name>
<affiliation>
<wicri:noCountry code="subField">University of GiessenGermany</wicri:noCountry>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Journal of Cataract & Refractive Surgery</title>
<title level="j" type="abbrev">JCRS</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1995">1995</date>
<biblScope unit="volume">21</biblScope>
<biblScope unit="issue">4</biblScope>
<biblScope unit="page" from="417">417</biblScope>
<biblScope unit="page" to="424">424</biblScope>
</imprint>
<idno type="ISSN">0886-3350</idno>
</series>
<idno type="istex">2DCB1BB2B06EF3199284679C7BB70BC2E43BB43C</idno>
<idno type="DOI">10.1016/S0886-3350(13)80532-9</idno>
<idno type="PII">S0886-3350(13)80532-9</idno>
<idno type="ArticleID">80532</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>cataract surgery</term>
<term>clear corneal tunnel incision</term>
<term>corneal astigmatism</term>
<term>corneal topography</term>
<term>foldable intraocular lens</term>
<term>small incision</term>
<term>videokeratography</term>
</keywords>
</textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">A prospective, randomized study compared the surgically induced astigmatism after 3.5 mm, 4.0 mm, and 5.0 mm temporal corneal tunnel incisions over six months. We studied 60 eyes of 60 patients who had phacoemulsification through a two-step clear corneal tunnel incision and implantation of one of three posterior chamber intraocular lenses (IOLs). Patients were divided into three groups of 20 each: Group A, cartridge injection of a foldable plate-haptic silicone IOL through a 3.5 mm self-sealing incision; Group B, cartridge injection of a disc silicone IOL through a 4.0 mm self-sealing incision; Group C, 5.0 mm optic poly(methyl methacrylate) IOL through a 5.0 mm incision with one radial suture. Corneal topography data were obtained using a computerized videokeratographic analysis system preoperatively and one week and six months postoperatively. Vector analysis was performed to calculate the surgically induced astigmatism. After the first postoperative week, mean induced astigmatism was 0.63 diopters (D) (±0.41) in Group A, 0.64 D (±0.35) in Group B, and 0.91 D (±0.77) in Group C. After six months, it was 0.37 D (±0.14) in Group A, 0.56 D (±0.34) in Group B, and 0.70 D (±0.50) in Group C. Surgically induced astigmatism was significantly lower in Group A than in Group B (P < .05) and Group C (P < .005) after six months. Vector analysis demonstrated that temporal corneal tunnel incisions induced clinically minimal astigmatism over six months postoperatively depending on incision size.</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 009A86 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 009A86 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Merge
   |type=    RBID
   |clé=     ISTEX:2DCB1BB2B06EF3199284679C7BB70BC2E43BB43C
   |texte=   Comparison of the induced astigmatism after temporal clear corneal tunnel incisions of different sizes
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024