CHARACTERIZATION OF AORTIC TISSUE CUTTING PROCESS: EXPERIMENTAL INVESTIGATION USING PORCINE ASCENDING AORTA
Identifieur interne : 002558 ( Main/Merge ); précédent : 002557; suivant : 002559CHARACTERIZATION OF AORTIC TISSUE CUTTING PROCESS: EXPERIMENTAL INVESTIGATION USING PORCINE ASCENDING AORTA
Auteurs : Zhongwei Hu [États-Unis] ; Wei Sun [États-Unis] ; Bi Zhang [États-Unis]Source :
- Journal of the mechanical behavior of biomedical materials [ 1751-6161 ] ; 2012.
English descriptors
- KwdEn :
- MESH :
- cytology : Aorta.
- Animals, Biomechanical Phenomena, Materials Testing, Mechanical Processes, Swine.
Abstract
Understanding biomechanical responses during soft tissue cutting is important for developing surgical simulators and robot-assisted surgery with haptic feedback. The biomechanics involved in the aortic tissue cutting process is largely unknown. In this study, porcine ascending aorta was selected as a representative aortic tissue, and tissue cutting experiments were performed using a novel tissue cutting apparatus. The tissue cutting responses under various cutting conditions were investigated, including differing initial tissue lateral holding force and distance, cutting speed, cutter inclination angle, tissue anatomical orientation and thickness. The results from this study suggest that a “break-in” cutting force of about 4 – 12 N, a cutter “break-in” distance of 5 – 15 mm, and a continuous cutting force of 2 – 4 N were needed to cut through the porcine ascending aorta tissue. For all testing conditions investigated in this study, the cutting force vs. the cutter displacement curves exhibited similar characteristics. More importantly, this study demonstrated that tissue cutting involving one or more of the following conditions: a larger lateral holding force, a smaller lateral hold distance, a higher cutting speed or a larger inclination angle, could result in a smaller “break in” cutting force and a smaller “break-in” distance. In addition, it was found that the cutting force in the vessel longitudinal direction was larger than that in the circumferential direction. There was a strong correlation between the tissue thickness and the cutting force. The experimental results reported in this study could provide a basis for understanding the characteristic response of aortic tissue to scalpel cutting, and offer insight into the development of surgical simulators.
Url:
DOI: 10.1016/j.jmbbm.2012.10.017
PubMed: 23262306
PubMed Central: 3557667
Links toward previous steps (curation, corpus...)
- to stream Pmc, to step Corpus: 001794
- to stream Pmc, to step Curation: 001794
- to stream Pmc, to step Checkpoint: 001826
- to stream PubMed, to step Corpus: 000A80
- to stream PubMed, to step Curation: 000A80
- to stream PubMed, to step Checkpoint: 000954
- to stream Ncbi, to step Merge: 002404
- to stream Ncbi, to step Curation: 002404
- to stream Ncbi, to step Checkpoint: 002404
Links to Exploration step
PMC:3557667Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">CHARACTERIZATION OF AORTIC TISSUE CUTTING PROCESS: EXPERIMENTAL INVESTIGATION USING PORCINE ASCENDING AORTA</title>
<author><name sortKey="Hu, Zhongwei" sort="Hu, Zhongwei" uniqKey="Hu Z" first="Zhongwei" last="Hu">Zhongwei Hu</name>
<affiliation wicri:level="2"><nlm:aff id="A1">Tissue Mechanics Laboratory, Biomedical Engineering Program, University of Connecticut, Storrs, CT 06269</nlm:aff>
<country xml:lang="fr">États-Unis</country>
<placeName><region type="state">Connecticut</region>
</placeName>
<wicri:cityArea>Tissue Mechanics Laboratory, Biomedical Engineering Program, University of Connecticut, Storrs</wicri:cityArea>
</affiliation>
<affiliation wicri:level="2"><nlm:aff id="A2">Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269</nlm:aff>
<country xml:lang="fr">États-Unis</country>
<placeName><region type="state">Connecticut</region>
</placeName>
<wicri:cityArea>Department of Mechanical Engineering, University of Connecticut, Storrs</wicri:cityArea>
</affiliation>
<affiliation><nlm:aff id="A3">Mechanical & Vehicle Engineering, Hunan University, Changsha, China, 410082</nlm:aff>
<wicri:noCountry code="subfield">410082</wicri:noCountry>
</affiliation>
</author>
<author><name sortKey="Sun, Wei" sort="Sun, Wei" uniqKey="Sun W" first="Wei" last="Sun">Wei Sun</name>
<affiliation wicri:level="2"><nlm:aff id="A1">Tissue Mechanics Laboratory, Biomedical Engineering Program, University of Connecticut, Storrs, CT 06269</nlm:aff>
<country xml:lang="fr">États-Unis</country>
<placeName><region type="state">Connecticut</region>
</placeName>
<wicri:cityArea>Tissue Mechanics Laboratory, Biomedical Engineering Program, University of Connecticut, Storrs</wicri:cityArea>
</affiliation>
<affiliation wicri:level="2"><nlm:aff id="A2">Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269</nlm:aff>
<country xml:lang="fr">États-Unis</country>
<placeName><region type="state">Connecticut</region>
</placeName>
<wicri:cityArea>Department of Mechanical Engineering, University of Connecticut, Storrs</wicri:cityArea>
</affiliation>
</author>
<author><name sortKey="Zhang, Bi" sort="Zhang, Bi" uniqKey="Zhang B" first="Bi" last="Zhang">Bi Zhang</name>
<affiliation wicri:level="2"><nlm:aff id="A2">Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269</nlm:aff>
<country xml:lang="fr">États-Unis</country>
<placeName><region type="state">Connecticut</region>
</placeName>
<wicri:cityArea>Department of Mechanical Engineering, University of Connecticut, Storrs</wicri:cityArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PMC</idno>
<idno type="pmid">23262306</idno>
<idno type="pmc">3557667</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3557667</idno>
<idno type="RBID">PMC:3557667</idno>
<idno type="doi">10.1016/j.jmbbm.2012.10.017</idno>
<date when="2012">2012</date>
<idno type="wicri:Area/Pmc/Corpus">001794</idno>
<idno type="wicri:Area/Pmc/Curation">001794</idno>
<idno type="wicri:Area/Pmc/Checkpoint">001826</idno>
<idno type="wicri:source">PubMed</idno>
<idno type="wicri:Area/PubMed/Corpus">000A80</idno>
<idno type="wicri:Area/PubMed/Curation">000A80</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000954</idno>
<idno type="wicri:Area/Ncbi/Merge">002404</idno>
<idno type="wicri:Area/Ncbi/Curation">002404</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">002404</idno>
<idno type="wicri:doubleKey">1751-6161:2012:Hu Z:characterization:of:aortic</idno>
<idno type="wicri:Area/Main/Merge">002558</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a" type="main">CHARACTERIZATION OF AORTIC TISSUE CUTTING PROCESS: EXPERIMENTAL INVESTIGATION USING PORCINE ASCENDING AORTA</title>
<author><name sortKey="Hu, Zhongwei" sort="Hu, Zhongwei" uniqKey="Hu Z" first="Zhongwei" last="Hu">Zhongwei Hu</name>
<affiliation wicri:level="2"><nlm:aff id="A1">Tissue Mechanics Laboratory, Biomedical Engineering Program, University of Connecticut, Storrs, CT 06269</nlm:aff>
<country xml:lang="fr">États-Unis</country>
<placeName><region type="state">Connecticut</region>
</placeName>
<wicri:cityArea>Tissue Mechanics Laboratory, Biomedical Engineering Program, University of Connecticut, Storrs</wicri:cityArea>
</affiliation>
<affiliation wicri:level="2"><nlm:aff id="A2">Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269</nlm:aff>
<country xml:lang="fr">États-Unis</country>
<placeName><region type="state">Connecticut</region>
</placeName>
<wicri:cityArea>Department of Mechanical Engineering, University of Connecticut, Storrs</wicri:cityArea>
</affiliation>
<affiliation><nlm:aff id="A3">Mechanical & Vehicle Engineering, Hunan University, Changsha, China, 410082</nlm:aff>
<wicri:noCountry code="subfield">410082</wicri:noCountry>
</affiliation>
</author>
<author><name sortKey="Sun, Wei" sort="Sun, Wei" uniqKey="Sun W" first="Wei" last="Sun">Wei Sun</name>
<affiliation wicri:level="2"><nlm:aff id="A1">Tissue Mechanics Laboratory, Biomedical Engineering Program, University of Connecticut, Storrs, CT 06269</nlm:aff>
<country xml:lang="fr">États-Unis</country>
<placeName><region type="state">Connecticut</region>
</placeName>
<wicri:cityArea>Tissue Mechanics Laboratory, Biomedical Engineering Program, University of Connecticut, Storrs</wicri:cityArea>
</affiliation>
<affiliation wicri:level="2"><nlm:aff id="A2">Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269</nlm:aff>
<country xml:lang="fr">États-Unis</country>
<placeName><region type="state">Connecticut</region>
</placeName>
<wicri:cityArea>Department of Mechanical Engineering, University of Connecticut, Storrs</wicri:cityArea>
</affiliation>
</author>
<author><name sortKey="Zhang, Bi" sort="Zhang, Bi" uniqKey="Zhang B" first="Bi" last="Zhang">Bi Zhang</name>
<affiliation wicri:level="2"><nlm:aff id="A2">Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269</nlm:aff>
<country xml:lang="fr">États-Unis</country>
<placeName><region type="state">Connecticut</region>
</placeName>
<wicri:cityArea>Department of Mechanical Engineering, University of Connecticut, Storrs</wicri:cityArea>
</affiliation>
</author>
</analytic>
<series><title level="j">Journal of the mechanical behavior of biomedical materials</title>
<idno type="ISSN">1751-6161</idno>
<idno type="eISSN">1878-0180</idno>
<imprint><date when="2012">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Animals</term>
<term>Aorta (cytology)</term>
<term>Biomechanical Phenomena</term>
<term>Materials Testing</term>
<term>Mechanical Processes</term>
<term>Swine</term>
</keywords>
<keywords scheme="MESH" qualifier="cytology" xml:lang="en"><term>Aorta</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Animals</term>
<term>Biomechanical Phenomena</term>
<term>Materials Testing</term>
<term>Mechanical Processes</term>
<term>Swine</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en"><p id="P2">Understanding biomechanical responses during soft tissue cutting is important for developing surgical simulators and robot-assisted surgery with haptic feedback. The biomechanics involved in the aortic tissue cutting process is largely unknown. In this study, porcine ascending aorta was selected as a representative aortic tissue, and tissue cutting experiments were performed using a novel tissue cutting apparatus. The tissue cutting responses under various cutting conditions were investigated, including differing initial tissue lateral holding force and distance, cutting speed, cutter inclination angle, tissue anatomical orientation and thickness. The results from this study suggest that a “break-in” cutting force of about 4 – 12 N, a cutter “break-in” distance of 5 – 15 mm, and a continuous cutting force of 2 – 4 N were needed to cut through the porcine ascending aorta tissue. For all testing conditions investigated in this study, the cutting force vs. the cutter displacement curves exhibited similar characteristics. More importantly, this study demonstrated that tissue cutting involving one or more of the following conditions: a larger lateral holding force, a smaller lateral hold distance, a higher cutting speed or a larger inclination angle, could result in a smaller “break in” cutting force and a smaller “break-in” distance. In addition, it was found that the cutting force in the vessel longitudinal direction was larger than that in the circumferential direction. There was a strong correlation between the tissue thickness and the cutting force. The experimental results reported in this study could provide a basis for understanding the characteristic response of aortic tissue to scalpel cutting, and offer insight into the development of surgical simulators.</p>
</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002558 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 002558 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Merge |type= RBID |clé= PMC:3557667 |texte= CHARACTERIZATION OF AORTIC TISSUE CUTTING PROCESS: EXPERIMENTAL INVESTIGATION USING PORCINE ASCENDING AORTA }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Merge/RBID.i -Sk "pubmed:23262306" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Merge/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |