Development of a New Valid, Reliable, and Internationally Applicable Assessment Tool of Residents’ Competence in Ophthalmic Surgery (An American Ophthalmological Society Thesis)
Identifieur interne : 001C81 ( Main/Merge ); précédent : 001C80; suivant : 001C82Development of a New Valid, Reliable, and Internationally Applicable Assessment Tool of Residents’ Competence in Ophthalmic Surgery (An American Ophthalmological Society Thesis)
Auteurs : C. Golnik ; Hilary Beaver ; Vinod Gauba ; Andrew G. Lee ; Eduardo Mayorga ; Gabriela Palis ; George M. SalehSource :
- Transactions of the American Ophthalmological Society [ 0065-9533 ] ; 2013.
Abstract
To test the validity and reliability of a new tool for assessing residents’ competence in ophthalmic surgery. Changing paradigms of ophthalmic education in the United States have influenced worldwide ophthalmic education and necessitated new methods of assessing resident competence. Accordingly, a new tool for assessing residents’ competence in ophthalmic surgery (phacoemulsification) that could be applicable internationally was developed. We hypothesize that this instrument is valid and reliable.
A panel of six international content experts adapted a previously published tool for assessing phacoemulsification. The tool (called the International Council of Ophthalmology’s Ophthalmology Surgical Competency Assessment Rubric, or ICO-OSCAR:phaco) was reviewed by 12 international content experts for their constructive comments, which were incorporated to ensure content validity. Ten expert cataract surgery teachers then graded six recorded phacoemulsification surgeries with the ICO-OSCAR:phaco to investigate inter-rater reliability.
The coefficient alpha statistic (a measure of reliability/internal consistency) for the ICO-OSCAR:phaco as a whole was 0.92, and 17 of its 20 dimensions had alpha coefficients greater than 0.70.
The ICO-OSCAR:phaco is a valid and reliable assessment tool that could be applied internationally to satisfy the global need of new instruments to comply with emerging trends in ophthalmic education. A toolbox of similar surgical competency assessment tools is being developed.
Url:
PubMed: 24072944
PubMed Central: 3783252
Links toward previous steps (curation, corpus...)
- to stream Pmc, to step Corpus: 001575
- to stream Pmc, to step Curation: 001575
- to stream Pmc, to step Checkpoint: 001324
- to stream Ncbi, to step Merge: 002977
- to stream Ncbi, to step Curation: 002977
- to stream Ncbi, to step Checkpoint: 002977
Links to Exploration step
PMC:3783252Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Development of a New Valid, Reliable, and Internationally Applicable Assessment Tool of Residents’ Competence in Ophthalmic Surgery (An American Ophthalmological Society Thesis)</title>
<author><name sortKey="Golnik, C" sort="Golnik, C" uniqKey="Golnik C" first="C." last="Golnik">C. Golnik</name>
</author>
<author><name sortKey="Beaver, Hilary" sort="Beaver, Hilary" uniqKey="Beaver H" first="Hilary" last="Beaver">Hilary Beaver</name>
</author>
<author><name sortKey="Gauba, Vinod" sort="Gauba, Vinod" uniqKey="Gauba V" first="Vinod" last="Gauba">Vinod Gauba</name>
</author>
<author><name sortKey="Lee, Andrew G" sort="Lee, Andrew G" uniqKey="Lee A" first="Andrew G." last="Lee">Andrew G. Lee</name>
</author>
<author><name sortKey="Mayorga, Eduardo" sort="Mayorga, Eduardo" uniqKey="Mayorga E" first="Eduardo" last="Mayorga">Eduardo Mayorga</name>
</author>
<author><name sortKey="Palis, Gabriela" sort="Palis, Gabriela" uniqKey="Palis G" first="Gabriela" last="Palis">Gabriela Palis</name>
</author>
<author><name sortKey="Saleh, George M" sort="Saleh, George M" uniqKey="Saleh G" first="George M." last="Saleh">George M. Saleh</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PMC</idno>
<idno type="pmid">24072944</idno>
<idno type="pmc">3783252</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3783252</idno>
<idno type="RBID">PMC:3783252</idno>
<date when="2013">2013</date>
<idno type="wicri:Area/Pmc/Corpus">001575</idno>
<idno type="wicri:Area/Pmc/Curation">001575</idno>
<idno type="wicri:Area/Pmc/Checkpoint">001324</idno>
<idno type="wicri:Area/Ncbi/Merge">002977</idno>
<idno type="wicri:Area/Ncbi/Curation">002977</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">002977</idno>
<idno type="wicri:doubleKey">0065-9533:2013:Golnik C:development:of:a</idno>
<idno type="wicri:Area/Main/Merge">001C81</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a" type="main">Development of a New Valid, Reliable, and Internationally Applicable Assessment Tool of Residents’ Competence in Ophthalmic Surgery (An American Ophthalmological Society Thesis)</title>
<author><name sortKey="Golnik, C" sort="Golnik, C" uniqKey="Golnik C" first="C." last="Golnik">C. Golnik</name>
</author>
<author><name sortKey="Beaver, Hilary" sort="Beaver, Hilary" uniqKey="Beaver H" first="Hilary" last="Beaver">Hilary Beaver</name>
</author>
<author><name sortKey="Gauba, Vinod" sort="Gauba, Vinod" uniqKey="Gauba V" first="Vinod" last="Gauba">Vinod Gauba</name>
</author>
<author><name sortKey="Lee, Andrew G" sort="Lee, Andrew G" uniqKey="Lee A" first="Andrew G." last="Lee">Andrew G. Lee</name>
</author>
<author><name sortKey="Mayorga, Eduardo" sort="Mayorga, Eduardo" uniqKey="Mayorga E" first="Eduardo" last="Mayorga">Eduardo Mayorga</name>
</author>
<author><name sortKey="Palis, Gabriela" sort="Palis, Gabriela" uniqKey="Palis G" first="Gabriela" last="Palis">Gabriela Palis</name>
</author>
<author><name sortKey="Saleh, George M" sort="Saleh, George M" uniqKey="Saleh G" first="George M." last="Saleh">George M. Saleh</name>
</author>
</analytic>
<series><title level="j">Transactions of the American Ophthalmological Society</title>
<idno type="ISSN">0065-9533</idno>
<idno type="eISSN">1545-6110</idno>
<imprint><date when="2013">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en"><sec><title>Purpose:</title>
<p>To test the validity and reliability of a new tool for assessing residents’ competence in ophthalmic surgery. Changing paradigms of ophthalmic education in the United States have influenced worldwide ophthalmic education and necessitated new methods of assessing resident competence. Accordingly, a new tool for assessing residents’ competence in ophthalmic surgery (phacoemulsification) that could be applicable internationally was developed. We hypothesize that this instrument is valid and reliable.</p>
</sec>
<sec><title>Methods:</title>
<p>A panel of six international content experts adapted a previously published tool for assessing phacoemulsification. The tool (called the International Council of Ophthalmology’s Ophthalmology Surgical Competency Assessment Rubric, or ICO-OSCAR:phaco) was reviewed by 12 international content experts for their constructive comments, which were incorporated to ensure content validity. Ten expert cataract surgery teachers then graded six recorded phacoemulsification surgeries with the ICO-OSCAR:phaco to investigate inter-rater reliability.</p>
</sec>
<sec><title>Results:</title>
<p>The coefficient alpha statistic (a measure of reliability/internal consistency) for the ICO-OSCAR:phaco as a whole was 0.92, and 17 of its 20 dimensions had alpha coefficients greater than 0.70.</p>
</sec>
<sec><title>Conclusions:</title>
<p>The ICO-OSCAR:phaco is a valid and reliable assessment tool that could be applied internationally to satisfy the global need of new instruments to comply with emerging trends in ophthalmic education. A toolbox of similar surgical competency assessment tools is being developed.</p>
</sec>
</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001C81 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 001C81 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Merge |type= RBID |clé= PMC:3783252 |texte= Development of a New Valid, Reliable, and Internationally Applicable Assessment Tool of Residents’ Competence in Ophthalmic Surgery (An American Ophthalmological Society Thesis) }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Merge/RBID.i -Sk "pubmed:24072944" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Merge/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |