Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation – Our experience

Identifieur interne : 000745 ( Main/Merge ); précédent : 000744; suivant : 000746

Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation – Our experience

Auteurs : Javed Hussain Farooqui ; Archana Koul ; Ranjan Dutta ; Noshir Minoo Shroff

Source :

RBID : PMC:4625364

Abstract

Purpose

Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism.

Setting

Cataract services, Shroff Eye Centre, New Delhi, India.

Design

Case series.

Method

This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months.

Results

The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was −0.04 (SD = 0.76).

Conclusion

We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery.


Url:
DOI: 10.1016/j.sjopt.2015.07.002
PubMed: 26586976
PubMed Central: 4625364

Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:4625364

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation – Our experience</title>
<author>
<name sortKey="Farooqui, Javed Hussain" sort="Farooqui, Javed Hussain" uniqKey="Farooqui J" first="Javed Hussain" last="Farooqui">Javed Hussain Farooqui</name>
</author>
<author>
<name sortKey="Koul, Archana" sort="Koul, Archana" uniqKey="Koul A" first="Archana" last="Koul">Archana Koul</name>
</author>
<author>
<name sortKey="Dutta, Ranjan" sort="Dutta, Ranjan" uniqKey="Dutta R" first="Ranjan" last="Dutta">Ranjan Dutta</name>
</author>
<author>
<name sortKey="Shroff, Noshir Minoo" sort="Shroff, Noshir Minoo" uniqKey="Shroff N" first="Noshir Minoo" last="Shroff">Noshir Minoo Shroff</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">26586976</idno>
<idno type="pmc">4625364</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4625364</idno>
<idno type="RBID">PMC:4625364</idno>
<idno type="doi">10.1016/j.sjopt.2015.07.002</idno>
<date when="2015">2015</date>
<idno type="wicri:Area/Pmc/Corpus">001568</idno>
<idno type="wicri:Area/Pmc/Curation">001568</idno>
<idno type="wicri:Area/Pmc/Checkpoint">000466</idno>
<idno type="wicri:Area/Ncbi/Merge">003D67</idno>
<idno type="wicri:Area/Ncbi/Curation">003D67</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">003D67</idno>
<idno type="wicri:doubleKey">1319-4534:2015:Farooqui J:management:of:moderate</idno>
<idno type="wicri:Area/Main/Merge">000745</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation – Our experience</title>
<author>
<name sortKey="Farooqui, Javed Hussain" sort="Farooqui, Javed Hussain" uniqKey="Farooqui J" first="Javed Hussain" last="Farooqui">Javed Hussain Farooqui</name>
</author>
<author>
<name sortKey="Koul, Archana" sort="Koul, Archana" uniqKey="Koul A" first="Archana" last="Koul">Archana Koul</name>
</author>
<author>
<name sortKey="Dutta, Ranjan" sort="Dutta, Ranjan" uniqKey="Dutta R" first="Ranjan" last="Dutta">Ranjan Dutta</name>
</author>
<author>
<name sortKey="Shroff, Noshir Minoo" sort="Shroff, Noshir Minoo" uniqKey="Shroff N" first="Noshir Minoo" last="Shroff">Noshir Minoo Shroff</name>
</author>
</analytic>
<series>
<title level="j">Saudi Journal of Ophthalmology</title>
<idno type="ISSN">1319-4534</idno>
<imprint>
<date when="2015">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec>
<title>Purpose</title>
<p>Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism.</p>
</sec>
<sec>
<title>Setting</title>
<p>Cataract services, Shroff Eye Centre, New Delhi, India.</p>
</sec>
<sec>
<title>Design</title>
<p>Case series.</p>
</sec>
<sec>
<title>Method</title>
<p>This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months.</p>
</sec>
<sec>
<title>Results</title>
<p>The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was −0.04 (SD = 0.76).</p>
</sec>
<sec>
<title>Conclusion</title>
<p>We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery.</p>
</sec>
</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000745 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 000745 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Merge
   |type=    RBID
   |clé=     PMC:4625364
   |texte=   Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation – Our experience
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Merge/RBID.i   -Sk "pubmed:26586976" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024