Abstract

The acceptance of master-slave robotic teleoperated applications in the medical field is related not only to the accuracy and precision of the robotic systems but also to the haptic features. Indeed, the capability to render a good haptic feeling, hence the sensation to drive the real surgical tool, is necessary for reaching an effective interaction between surgeon and robotic system. In this paper an innovative controller for master-slave haptic systems for neurosurgery has been developed by getting inspiration from force reflecting controllers and non-time based control schemes. This new DFORCE (Delayed FOrce ReferenCE) controller is founded on the basic idea to control the position of the device through a system that can generate forces on the master side only when the surgeon is grasping the haptic handle. Thus, when the surgeon is not grasping the haptic handle and external forces are present, the system remains stable. The haptic sensation, the stability and the readiness of the system have been studied and a tuning procedure proposed. Moreover, simulated and experimental tests on a test-bed master system and a haptic master-slave interface for neurosurgical operations have been carried out in order to demonstrate the effectiveness of the controller.


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">DFORCE: Delayed FOrce ReferenCE control for master-slave robotic systems</title>
<author>
<name sortKey="Gasparetto, A" sort="Gasparetto, A" uniqKey="Gasparetto A" first="A." last="Gasparetto">A. Gasparetto</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>DIEGM - Department of Electrical, Management and Mechanical Engineering, University of Udine, Via delle Scienze</s1>
<s2>208- 33100 Udine</s2>
<s3>ITA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>Italie</country>
<wicri:noRegion>208- 33100 Udine</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Vidoni, R" sort="Vidoni, R" uniqKey="Vidoni R" first="R." last="Vidoni">R. Vidoni</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>DIEGM - Department of Electrical, Management and Mechanical Engineering, University of Udine, Via delle Scienze</s1>
<s2>208- 33100 Udine</s2>
<s3>ITA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>Italie</country>
<wicri:noRegion>208- 33100 Udine</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Zanotto, V" sort="Zanotto, V" uniqKey="Zanotto V" first="V." last="Zanotto">V. Zanotto</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>DIEGM - Department of Electrical, Management and Mechanical Engineering, University of Udine, Via delle Scienze</s1>
<s2>208- 33100 Udine</s2>
<s3>ITA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>Italie</country>
<wicri:noRegion>208- 33100 Udine</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">09-0412882</idno>
<date when="2009">2009</date>
<idno type="stanalyst">PASCAL 09-0412882 INIST</idno>
<idno type="RBID">Pascal:09-0412882</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000746</idno>
<idno type="wicri:Area/PascalFrancis/Curation">000C87</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">000612</idno>
<idno type="wicri:doubleKey">0957-4158:2009:Gasparetto A:dforce:delayed:force</idno>
<idno type="wicri:Area/Main/Merge">004A05</idno>
<idno type="wicri:Area/Main/Curation">004919</idno>
<idno type="wicri:Area/Main/Exploration">004919</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">DFORCE: Delayed FOrce ReferenCE control for master-slave robotic systems</title>
<author>
<name sortKey="Gasparetto, A" sort="Gasparetto, A" uniqKey="Gasparetto A" first="A." last="Gasparetto">A. Gasparetto</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>DIEGM - Department of Electrical, Management and Mechanical Engineering, University of Udine, Via delle Scienze</s1>
<s2>208- 33100 Udine</s2>
<s3>ITA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>Italie</country>
<wicri:noRegion>208- 33100 Udine</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Vidoni, R" sort="Vidoni, R" uniqKey="Vidoni R" first="R." last="Vidoni">R. Vidoni</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>DIEGM - Department of Electrical, Management and Mechanical Engineering, University of Udine, Via delle Scienze</s1>
<s2>208- 33100 Udine</s2>
<s3>ITA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>Italie</country>
<wicri:noRegion>208- 33100 Udine</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Zanotto, V" sort="Zanotto, V" uniqKey="Zanotto V" first="V." last="Zanotto">V. Zanotto</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>DIEGM - Department of Electrical, Management and Mechanical Engineering, University of Udine, Via delle Scienze</s1>
<s2>208- 33100 Udine</s2>
<s3>ITA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>Italie</country>
<wicri:noRegion>208- 33100 Udine</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series>
<title level="j" type="main">Mechatronics : (Oxford)</title>
<title level="j" type="abbreviated">Mechatronics : (Oxf.)</title>
<idno type="ISSN">0957-4158</idno>
<imprint>
<date when="2009">2009</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">Mechatronics : (Oxford)</title>
<title level="j" type="abbreviated">Mechatronics : (Oxf.)</title>
<idno type="ISSN">0957-4158</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Delay control</term>
<term>Force control</term>
<term>Gripping</term>
<term>Master slave relationship</term>
<term>Medical application</term>
<term>Nervous system diseases</term>
<term>Position control</term>
<term>Remote operation</term>
<term>Robotics</term>
<term>Surgery</term>
<term>Tactile sensitivity</term>
<term>User interface</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Commande à retard</term>
<term>Commande force</term>
<term>Robotique</term>
<term>Téléopération</term>
<term>Commande position</term>
<term>Relation maître esclave</term>
<term>Application médicale</term>
<term>Sensibilité tactile</term>
<term>Chirurgie</term>
<term>Pathologie du système nerveux</term>
<term>Préhension</term>
<term>Interface utilisateur</term>
<term>.</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr">
<term>Robotique</term>
<term>Chirurgie</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The acceptance of master-slave robotic teleoperated applications in the medical field is related not only to the accuracy and precision of the robotic systems but also to the haptic features. Indeed, the capability to render a good haptic feeling, hence the sensation to drive the real surgical tool, is necessary for reaching an effective interaction between surgeon and robotic system. In this paper an innovative controller for master-slave haptic systems for neurosurgery has been developed by getting inspiration from force reflecting controllers and non-time based control schemes. This new DFORCE (Delayed FOrce ReferenCE) controller is founded on the basic idea to control the position of the device through a system that can generate forces on the master side only when the surgeon is grasping the haptic handle. Thus, when the surgeon is not grasping the haptic handle and external forces are present, the system remains stable. The haptic sensation, the stability and the readiness of the system have been studied and a tuning procedure proposed. Moreover, simulated and experimental tests on a test-bed master system and a haptic master-slave interface for neurosurgical operations have been carried out in order to demonstrate the effectiveness of the controller.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Italie</li>
</country>
</list>
<tree>
<country name="Italie">
<noRegion>
<name sortKey="Gasparetto, A" sort="Gasparetto, A" uniqKey="Gasparetto A" first="A." last="Gasparetto">A. Gasparetto</name>
</noRegion>
<name sortKey="Vidoni, R" sort="Vidoni, R" uniqKey="Vidoni R" first="R." last="Vidoni">R. Vidoni</name>
<name sortKey="Zanotto, V" sort="Zanotto, V" uniqKey="Zanotto V" first="V." last="Zanotto">V. Zanotto</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004919 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 004919 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     Pascal:09-0412882
   |texte=   DFORCE: Delayed FOrce ReferenCE control for master-slave robotic systems
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024