Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

New two-point scleral-fixation technique for foldable intraocular lenses with four hollow haptics

Identifieur interne : 000138 ( Main/Exploration ); précédent : 000137; suivant : 000139

New two-point scleral-fixation technique for foldable intraocular lenses with four hollow haptics

Auteurs : He-Ting Liu ; Zheng-Xuan Jiang ; Li-Ming Tao

Source :

RBID : PMC:4844033

Abstract

The study was to report a new two-point scleral-fixation technique for foldable intraocular lenses with four haptics. Lenses were slid into the anterior chamber from a 2.8 mm corneal incision and fixed under two sclera flaps at two opposite points. The postoperative best-corrected visual acuities (BCVAs) of all patients were significantly better than their preoperative BCVA. The results demonstrate that two-point, scleral fixations of foldable, intraocular lenses might be practicable and effective.


Url:
DOI: 10.18240/ijo.2016.03.26
PubMed: 27158623
PubMed Central: 4844033


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">New two-point scleral-fixation technique for foldable intraocular lenses with four hollow haptics</title>
<author>
<name sortKey="Liu, He Ting" sort="Liu, He Ting" uniqKey="Liu H" first="He-Ting" last="Liu">He-Ting Liu</name>
</author>
<author>
<name sortKey="Jiang, Zheng Xuan" sort="Jiang, Zheng Xuan" uniqKey="Jiang Z" first="Zheng-Xuan" last="Jiang">Zheng-Xuan Jiang</name>
</author>
<author>
<name sortKey="Tao, Li Ming" sort="Tao, Li Ming" uniqKey="Tao L" first="Li-Ming" last="Tao">Li-Ming Tao</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">27158623</idno>
<idno type="pmc">4844033</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4844033</idno>
<idno type="RBID">PMC:4844033</idno>
<idno type="doi">10.18240/ijo.2016.03.26</idno>
<date when="2016">2016</date>
<idno type="wicri:Area/Pmc/Corpus">000455</idno>
<idno type="wicri:Area/Pmc/Curation">000455</idno>
<idno type="wicri:Area/Pmc/Checkpoint">000079</idno>
<idno type="wicri:Area/Ncbi/Merge">004223</idno>
<idno type="wicri:Area/Ncbi/Curation">004223</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">004223</idno>
<idno type="wicri:doubleKey">2222-3959:2016:Liu H:new:two:point</idno>
<idno type="wicri:Area/Main/Merge">000138</idno>
<idno type="wicri:Area/Main/Curation">000138</idno>
<idno type="wicri:Area/Main/Exploration">000138</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">New two-point scleral-fixation technique for foldable intraocular lenses with four hollow haptics</title>
<author>
<name sortKey="Liu, He Ting" sort="Liu, He Ting" uniqKey="Liu H" first="He-Ting" last="Liu">He-Ting Liu</name>
</author>
<author>
<name sortKey="Jiang, Zheng Xuan" sort="Jiang, Zheng Xuan" uniqKey="Jiang Z" first="Zheng-Xuan" last="Jiang">Zheng-Xuan Jiang</name>
</author>
<author>
<name sortKey="Tao, Li Ming" sort="Tao, Li Ming" uniqKey="Tao L" first="Li-Ming" last="Tao">Li-Ming Tao</name>
</author>
</analytic>
<series>
<title level="j">International Journal of Ophthalmology</title>
<idno type="ISSN">2222-3959</idno>
<idno type="eISSN">2227-4898</idno>
<imprint>
<date when="2016">2016</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>The study was to report a new two-point scleral-fixation technique for foldable intraocular lenses with four haptics. Lenses were slid into the anterior chamber from a 2.8 mm corneal incision and fixed under two sclera flaps at two opposite points. The postoperative best-corrected visual acuities (BCVAs) of all patients were significantly better than their preoperative BCVA. The results demonstrate that two-point, scleral fixations of foldable, intraocular lenses might be practicable and effective.</p>
</div>
</front>
</TEI>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Jiang, Zheng Xuan" sort="Jiang, Zheng Xuan" uniqKey="Jiang Z" first="Zheng-Xuan" last="Jiang">Zheng-Xuan Jiang</name>
<name sortKey="Liu, He Ting" sort="Liu, He Ting" uniqKey="Liu H" first="He-Ting" last="Liu">He-Ting Liu</name>
<name sortKey="Tao, Li Ming" sort="Tao, Li Ming" uniqKey="Tao L" first="Li-Ming" last="Tao">Li-Ming Tao</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000138 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000138 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     PMC:4844033
   |texte=   New two-point scleral-fixation technique for foldable intraocular lenses with four hollow haptics
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:27158623" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024