Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

[Adhesion of liquid perfluorocarbon to various intraocular lens materials. A light microscopy study].

Identifieur interne : 008431 ( Main/Exploration ); précédent : 008430; suivant : 008432

[Adhesion of liquid perfluorocarbon to various intraocular lens materials. A light microscopy study].

Auteurs : B. Dick ; O. Schwenn ; B. Stoffelns ; N. Pfeiffer

Source :

RBID : pubmed:9643021

English descriptors

Abstract

Perfluorocarbone liquids (PFCL) enable explantation of intraocular lenses (IOL) dislocated into the vitreous. Because of their relatively high specific weight, the IOL can be floated off the retina and repositioned in the anterior segment. If the IOL surface is affected by contact with PFCL is still unknown. We were interested in the extent of PFCL contact with different IOL materials, having in mind a repositioning of a dislocated IOL into the posterior chamber. We investigated the adherence of PFCL to different IOL surfaces.

PubMed: 9643021


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">[Adhesion of liquid perfluorocarbon to various intraocular lens materials. A light microscopy study].</title>
<author>
<name sortKey="Dick, B" sort="Dick, B" uniqKey="Dick B" first="B" last="Dick">B. Dick</name>
<affiliation>
<nlm:affiliation>Universitäts-Augenklinik, Mainz.</nlm:affiliation>
<wicri:noCountry code="subField">Mainz</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Schwenn, O" sort="Schwenn, O" uniqKey="Schwenn O" first="O" last="Schwenn">O. Schwenn</name>
</author>
<author>
<name sortKey="Stoffelns, B" sort="Stoffelns, B" uniqKey="Stoffelns B" first="B" last="Stoffelns">B. Stoffelns</name>
</author>
<author>
<name sortKey="Pfeiffer, N" sort="Pfeiffer, N" uniqKey="Pfeiffer N" first="N" last="Pfeiffer">N. Pfeiffer</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1998">1998</date>
<idno type="RBID">pubmed:9643021</idno>
<idno type="pmid">9643021</idno>
<idno type="wicri:Area/PubMed/Corpus">001F56</idno>
<idno type="wicri:Area/PubMed/Curation">001F56</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001C61</idno>
<idno type="wicri:Area/Ncbi/Merge">004721</idno>
<idno type="wicri:Area/Ncbi/Curation">004721</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">004721</idno>
<idno type="wicri:doubleKey">0941-293X:1998:Dick B:adhesion:of:liquid</idno>
<idno type="wicri:Area/Main/Merge">008B95</idno>
<idno type="wicri:Area/Main/Curation">008431</idno>
<idno type="wicri:Area/Main/Exploration">008431</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">[Adhesion of liquid perfluorocarbon to various intraocular lens materials. A light microscopy study].</title>
<author>
<name sortKey="Dick, B" sort="Dick, B" uniqKey="Dick B" first="B" last="Dick">B. Dick</name>
<affiliation>
<nlm:affiliation>Universitäts-Augenklinik, Mainz.</nlm:affiliation>
<wicri:noCountry code="subField">Mainz</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Schwenn, O" sort="Schwenn, O" uniqKey="Schwenn O" first="O" last="Schwenn">O. Schwenn</name>
</author>
<author>
<name sortKey="Stoffelns, B" sort="Stoffelns, B" uniqKey="Stoffelns B" first="B" last="Stoffelns">B. Stoffelns</name>
</author>
<author>
<name sortKey="Pfeiffer, N" sort="Pfeiffer, N" uniqKey="Pfeiffer N" first="N" last="Pfeiffer">N. Pfeiffer</name>
</author>
</analytic>
<series>
<title level="j">Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft</title>
<idno type="ISSN">0941-293X</idno>
<imprint>
<date when="1998" type="published">1998</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Fluorocarbons</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Microscopy</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
<term>Surface Properties</term>
<term>Tissue Adhesions</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Fluorocarbons</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Microscopy</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
<term>Surface Properties</term>
<term>Tissue Adhesions</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Perfluorocarbone liquids (PFCL) enable explantation of intraocular lenses (IOL) dislocated into the vitreous. Because of their relatively high specific weight, the IOL can be floated off the retina and repositioned in the anterior segment. If the IOL surface is affected by contact with PFCL is still unknown. We were interested in the extent of PFCL contact with different IOL materials, having in mind a repositioning of a dislocated IOL into the posterior chamber. We investigated the adherence of PFCL to different IOL surfaces.</div>
</front>
</TEI>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Dick, B" sort="Dick, B" uniqKey="Dick B" first="B" last="Dick">B. Dick</name>
<name sortKey="Pfeiffer, N" sort="Pfeiffer, N" uniqKey="Pfeiffer N" first="N" last="Pfeiffer">N. Pfeiffer</name>
<name sortKey="Schwenn, O" sort="Schwenn, O" uniqKey="Schwenn O" first="O" last="Schwenn">O. Schwenn</name>
<name sortKey="Stoffelns, B" sort="Stoffelns, B" uniqKey="Stoffelns B" first="B" last="Stoffelns">B. Stoffelns</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 008431 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 008431 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:9643021
   |texte=   [Adhesion of liquid perfluorocarbon to various intraocular lens materials. A light microscopy study].
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:9643021" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024