Anterior vaulting of single piece in-the-bag intraocular lens after blunt trauma
Identifieur interne : 002567 ( Main/Exploration ); précédent : 002566; suivant : 002568Anterior vaulting of single piece in-the-bag intraocular lens after blunt trauma
Auteurs : Seung Hoon Oh ; Jae Young Park ; Hye Bin Yim ; Na Young LeeSource :
- Journal of Optometry [ 1888-4296 ] ; 2012.
Abstract
A 64-year-old man complained of difficulty with far vision in the right eye after blunt trauma by his hand during sleep. He had undergone uneventful phacoemulsification and intraocular lens (IOL) implantation of both eyes one week before the event. On slit lamp examination, the anterior chamber was shallow compared to postoperative one day or the left eye. After mydriasis, IOL position was perfect, within the capsulorrhexis margin, and no haptics were protruded. SE of his right eye was −4.00 diopter after trauma, although spherical equivalent (SE) of both eyes was near emmetropia one day after cataract surgery. We decided on IOL reposition or exchange. Intraoperatively, we pushed the IOL posteriorly; the IOL was vaulted posteriorly, as expected. After surgery, his SE was +0.25 with the same diopter IOL. We report the case on the possibility of 4-point haptic IOL vaulting anteriorly by blunt trauma within the capsular bag.
Url:
DOI: 10.1016/j.optom.2011.11.003
PubMed: NONE
PubMed Central: 3861315
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Pmc, to step Corpus: 000C43
- to stream Pmc, to step Curation: 000C43
- to stream Pmc, to step Checkpoint: 001856
- to stream Ncbi, to step Merge: 004766
- to stream Ncbi, to step Curation: 004766
- to stream Ncbi, to step Checkpoint: 004766
- to stream Main, to step Merge: 002595
- to stream Main, to step Curation: 002567
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Anterior vaulting of single piece in-the-bag intraocular lens after blunt trauma</title>
<author><name sortKey="Oh, Seung Hoon" sort="Oh, Seung Hoon" uniqKey="Oh S" first="Seung Hoon" last="Oh">Seung Hoon Oh</name>
</author>
<author><name sortKey="Park, Jae Young" sort="Park, Jae Young" uniqKey="Park J" first="Jae Young" last="Park">Jae Young Park</name>
</author>
<author><name sortKey="Yim, Hye Bin" sort="Yim, Hye Bin" uniqKey="Yim H" first="Hye Bin" last="Yim">Hye Bin Yim</name>
</author>
<author><name sortKey="Lee, Na Young" sort="Lee, Na Young" uniqKey="Lee N" first="Na Young" last="Lee">Na Young Lee</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PMC</idno>
<idno type="pmc">3861315</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3861315</idno>
<idno type="RBID">PMC:3861315</idno>
<idno type="doi">10.1016/j.optom.2011.11.003</idno>
<idno type="pmid">NONE</idno>
<date when="2012">2012</date>
<idno type="wicri:Area/Pmc/Corpus">000C43</idno>
<idno type="wicri:Area/Pmc/Curation">000C43</idno>
<idno type="wicri:Area/Pmc/Checkpoint">001856</idno>
<idno type="wicri:Area/Ncbi/Merge">004766</idno>
<idno type="wicri:Area/Ncbi/Curation">004766</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">004766</idno>
<idno type="wicri:doubleKey">1888-4296:2012:Oh S:anterior:vaulting:of</idno>
<idno type="wicri:Area/Main/Merge">002595</idno>
<idno type="wicri:Area/Main/Curation">002567</idno>
<idno type="wicri:Area/Main/Exploration">002567</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a" type="main">Anterior vaulting of single piece in-the-bag intraocular lens after blunt trauma</title>
<author><name sortKey="Oh, Seung Hoon" sort="Oh, Seung Hoon" uniqKey="Oh S" first="Seung Hoon" last="Oh">Seung Hoon Oh</name>
</author>
<author><name sortKey="Park, Jae Young" sort="Park, Jae Young" uniqKey="Park J" first="Jae Young" last="Park">Jae Young Park</name>
</author>
<author><name sortKey="Yim, Hye Bin" sort="Yim, Hye Bin" uniqKey="Yim H" first="Hye Bin" last="Yim">Hye Bin Yim</name>
</author>
<author><name sortKey="Lee, Na Young" sort="Lee, Na Young" uniqKey="Lee N" first="Na Young" last="Lee">Na Young Lee</name>
</author>
</analytic>
<series><title level="j">Journal of Optometry</title>
<idno type="ISSN">1888-4296</idno>
<idno type="eISSN">1989-1342</idno>
<imprint><date when="2012">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en"><p>A 64-year-old man complained of difficulty with far vision in the right eye after blunt trauma by his hand during sleep. He had undergone uneventful phacoemulsification and intraocular lens (IOL) implantation of both eyes one week before the event. On slit lamp examination, the anterior chamber was shallow compared to postoperative one day or the left eye. After mydriasis, IOL position was perfect, within the capsulorrhexis margin, and no haptics were protruded. SE of his right eye was −4.00 diopter after trauma, although spherical equivalent (SE) of both eyes was near emmetropia one day after cataract surgery. We decided on IOL reposition or exchange. Intraoperatively, we pushed the IOL posteriorly; the IOL was vaulted posteriorly, as expected. After surgery, his SE was +0.25 with the same diopter IOL. We report the case on the possibility of 4-point haptic IOL vaulting anteriorly by blunt trauma within the capsular bag.</p>
</div>
</front>
</TEI>
<affiliations><list></list>
<tree><noCountry><name sortKey="Lee, Na Young" sort="Lee, Na Young" uniqKey="Lee N" first="Na Young" last="Lee">Na Young Lee</name>
<name sortKey="Oh, Seung Hoon" sort="Oh, Seung Hoon" uniqKey="Oh S" first="Seung Hoon" last="Oh">Seung Hoon Oh</name>
<name sortKey="Park, Jae Young" sort="Park, Jae Young" uniqKey="Park J" first="Jae Young" last="Park">Jae Young Park</name>
<name sortKey="Yim, Hye Bin" sort="Yim, Hye Bin" uniqKey="Yim H" first="Hye Bin" last="Yim">Hye Bin Yim</name>
</noCountry>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002567 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 002567 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Exploration |type= RBID |clé= PMC:3861315 |texte= Anterior vaulting of single piece in-the-bag intraocular lens after blunt trauma }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i -Sk "pubmed:NONE" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |