Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

12 year results of a prospective trial comparing poly(methyl methacrylate) and poly(hydroxyethyl methacrylate) intraocular lenses

Identifieur interne : 001561 ( Istex/Curation ); précédent : 001560; suivant : 001562

12 year results of a prospective trial comparing poly(methyl methacrylate) and poly(hydroxyethyl methacrylate) intraocular lenses

Auteurs : A. Jabbar Khan [Royaume-Uni] ; S. Piers B. Percival [Royaume-Uni]

Source :

RBID : ISTEX:DB23752781D15C9F3ABC899D78B90BDD91A604F3

Abstract

Purpose To compare long-term biocompatibility of single-piece poly(methyl methacrylate) (PMMA) and poly(hydroxyethyl methacrylate) (P-HEMA) intraocular lenses (IOLs).Setting District General Hospital, United Kingdom.Methods In a prospective trial of 250 eyes that had uncomplicated extracapsular cataract extraction, 2 groups of 125 eyes each were matched for age and sex. One group received single-piece looped PMMA IOLs and the other, single-piece solid-hapticP-HEMA IOLs. In all eyes, the IOLs were implanted in the capsular bag at the time of surgery using the envelope technique.Results Twelve years after surgery, 75 eyes were available for examination. In the PMMA group (40 eyes), 50% had a visual acuity of 20/20 and 50% had intact capsules, many of them with a degree of fibrosis. In the P-HEMA group (35 eyes), 71% had an acuity of 20/20 and 80% had intact capsules (P = .0085).Conclusion In the long term, biocompatibility was better in the P-HEMA group than in the PMMA group.

Url:
DOI: 10.1016/S0886-3350(99)00199-6

Links toward previous steps (curation, corpus...)


Links to Exploration step

ISTEX:DB23752781D15C9F3ABC899D78B90BDD91A604F3

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">12 year results of a prospective trial comparing poly(methyl methacrylate) and poly(hydroxyethyl methacrylate) intraocular lenses</title>
<author>
<name sortKey="Khan, A Jabbar" sort="Khan, A Jabbar" uniqKey="Khan A" first="A. Jabbar" last="Khan">A. Jabbar Khan</name>
<affiliation wicri:level="1">
<mods:affiliation>Department of Ophthalmology, Scarborough Hospital, Scarborough, England, United Kingdom</mods:affiliation>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Department of Ophthalmology, Scarborough Hospital, Scarborough, England</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Percival, S Piers B" sort="Percival, S Piers B" uniqKey="Percival S" first="S. Piers B" last="Percival">S. Piers B. Percival</name>
<affiliation wicri:level="1">
<mods:affiliation>Department of Ophthalmology, Scarborough Hospital, Scarborough, England, United Kingdom</mods:affiliation>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Department of Ophthalmology, Scarborough Hospital, Scarborough, England</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:DB23752781D15C9F3ABC899D78B90BDD91A604F3</idno>
<date when="1999" year="1999">1999</date>
<idno type="doi">10.1016/S0886-3350(99)00199-6</idno>
<idno type="url">https://api.istex.fr/document/DB23752781D15C9F3ABC899D78B90BDD91A604F3/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">001561</idno>
<idno type="wicri:Area/Istex/Curation">001561</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">12 year results of a prospective trial comparing poly(methyl methacrylate) and poly(hydroxyethyl methacrylate) intraocular lenses</title>
<author>
<name sortKey="Khan, A Jabbar" sort="Khan, A Jabbar" uniqKey="Khan A" first="A. Jabbar" last="Khan">A. Jabbar Khan</name>
<affiliation wicri:level="1">
<mods:affiliation>Department of Ophthalmology, Scarborough Hospital, Scarborough, England, United Kingdom</mods:affiliation>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Department of Ophthalmology, Scarborough Hospital, Scarborough, England</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Percival, S Piers B" sort="Percival, S Piers B" uniqKey="Percival S" first="S. Piers B" last="Percival">S. Piers B. Percival</name>
<affiliation wicri:level="1">
<mods:affiliation>Department of Ophthalmology, Scarborough Hospital, Scarborough, England, United Kingdom</mods:affiliation>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Department of Ophthalmology, Scarborough Hospital, Scarborough, England</wicri:regionArea>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Journal of Cataract & Refractive Surgery</title>
<title level="j" type="abbrev">JCRS</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1999">1999</date>
<biblScope unit="volume">25</biblScope>
<biblScope unit="issue">10</biblScope>
<biblScope unit="page" from="1404">1404</biblScope>
<biblScope unit="page" to="1407">1407</biblScope>
</imprint>
<idno type="ISSN">0886-3350</idno>
</series>
<idno type="istex">DB23752781D15C9F3ABC899D78B90BDD91A604F3</idno>
<idno type="DOI">10.1016/S0886-3350(99)00199-6</idno>
<idno type="PII">S0886-3350(99)00199-6</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Purpose To compare long-term biocompatibility of single-piece poly(methyl methacrylate) (PMMA) and poly(hydroxyethyl methacrylate) (P-HEMA) intraocular lenses (IOLs).Setting District General Hospital, United Kingdom.Methods In a prospective trial of 250 eyes that had uncomplicated extracapsular cataract extraction, 2 groups of 125 eyes each were matched for age and sex. One group received single-piece looped PMMA IOLs and the other, single-piece solid-hapticP-HEMA IOLs. In all eyes, the IOLs were implanted in the capsular bag at the time of surgery using the envelope technique.Results Twelve years after surgery, 75 eyes were available for examination. In the PMMA group (40 eyes), 50% had a visual acuity of 20/20 and 50% had intact capsules, many of them with a degree of fibrosis. In the P-HEMA group (35 eyes), 71% had an acuity of 20/20 and 80% had intact capsules (P = .0085).Conclusion In the long term, biocompatibility was better in the P-HEMA group than in the PMMA group.</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Istex/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001561 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Curation/biblio.hfd -nk 001561 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Istex
   |étape=   Curation
   |type=    RBID
   |clé=     ISTEX:DB23752781D15C9F3ABC899D78B90BDD91A604F3
   |texte=   12 year results of a prospective trial comparing poly(methyl methacrylate) and poly(hydroxyethyl methacrylate) intraocular lenses
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024