[Digital recording of glow curves of the TLD-300 thermoluminescent dosimetry detector by adaptation of a sum of Gauss function to the measured values].

Identifieur interne : 000840 ( PubMed/Curation ); précédent : 000839; suivant : 000841

[Digital recording of glow curves of the TLD-300 thermoluminescent dosimetry detector by adaptation of a sum of Gauss function to the measured values].

Auteurs : P. Meissner

Source :

RBID : pubmed:3975938

Descripteurs français

English descriptors

Abstract

Calciumfluoride doped with Thulium (TLD-300) can be used to measure simultaneously with one detector neutron and photon absorbed dose in mixed neutron-photon beams. The accuracy in dose measurements can be increased by use of a computer. Additionally the number of data needed to store a glow curve can be reduced from 240 to 24 by fitting a sum of Gauss functions to the measured glow curve.

PubMed: 3975938

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:3975938

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">[Digital recording of glow curves of the TLD-300 thermoluminescent dosimetry detector by adaptation of a sum of Gauss function to the measured values].</title>
<author>
<name sortKey="Meissner, P" sort="Meissner, P" uniqKey="Meissner P" first="P" last="Meissner">P. Meissner</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1985">1985</date>
<idno type="RBID">pubmed:3975938</idno>
<idno type="pmid">3975938</idno>
<idno type="wicri:Area/PubMed/Corpus">000840</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000840</idno>
<idno type="wicri:Area/PubMed/Curation">000840</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000840</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">[Digital recording of glow curves of the TLD-300 thermoluminescent dosimetry detector by adaptation of a sum of Gauss function to the measured values].</title>
<author>
<name sortKey="Meissner, P" sort="Meissner, P" uniqKey="Meissner P" first="P" last="Meissner">P. Meissner</name>
</author>
</analytic>
<series>
<title level="j">Strahlentherapie</title>
<idno type="ISSN">0039-2073</idno>
<imprint>
<date when="1985" type="published">1985</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Calcium Fluoride (radiation effects)</term>
<term>Computers</term>
<term>Fast Neutrons</term>
<term>Mathematics</term>
<term>Radiation</term>
<term>Radiation Dosage</term>
<term>Thermodynamics</term>
<term>Thermoluminescent Dosimetry (instrumentation)</term>
<term>Thulium (radiation effects)</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Dose de radiation</term>
<term>Dosimétrie thermoluminescente (instrumentation)</term>
<term>Fluorure de calcium (effets des radiations)</term>
<term>Mathématiques</term>
<term>Neutrons rapides</term>
<term>Ordinateurs</term>
<term>Rayonnement</term>
<term>Thermodynamique</term>
<term>Thulium (effets des radiations)</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="radiation effects" xml:lang="en">
<term>Calcium Fluoride</term>
<term>Thulium</term>
</keywords>
<keywords scheme="MESH" qualifier="effets des radiations" xml:lang="fr">
<term>Fluorure de calcium</term>
<term>Thulium</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Thermoluminescent Dosimetry</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Computers</term>
<term>Fast Neutrons</term>
<term>Mathematics</term>
<term>Radiation</term>
<term>Radiation Dosage</term>
<term>Thermodynamics</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="fr">
<term>Dose de radiation</term>
<term>Dosimétrie thermoluminescente</term>
<term>Mathématiques</term>
<term>Neutrons rapides</term>
<term>Ordinateurs</term>
<term>Rayonnement</term>
<term>Thermodynamique</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Calciumfluoride doped with Thulium (TLD-300) can be used to measure simultaneously with one detector neutron and photon absorbed dose in mixed neutron-photon beams. The accuracy in dose measurements can be increased by use of a computer. Additionally the number of data needed to store a glow curve can be reduced from 240 to 24 by fitting a sum of Gauss functions to the measured glow curve.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">3975938</PMID>
<DateCreated>
<Year>1985</Year>
<Month>04</Month>
<Day>22</Day>
</DateCreated>
<DateCompleted>
<Year>1985</Year>
<Month>04</Month>
<Day>22</Day>
</DateCompleted>
<DateRevised>
<Year>2013</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0039-2073</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>161</Volume>
<Issue>2</Issue>
<PubDate>
<Year>1985</Year>
<Month>Feb</Month>
</PubDate>
</JournalIssue>
<Title>Strahlentherapie</Title>
<ISOAbbreviation>Strahlentherapie</ISOAbbreviation>
</Journal>
<ArticleTitle>[Digital recording of glow curves of the TLD-300 thermoluminescent dosimetry detector by adaptation of a sum of Gauss function to the measured values].</ArticleTitle>
<Pagination>
<MedlinePgn>102-6</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Calciumfluoride doped with Thulium (TLD-300) can be used to measure simultaneously with one detector neutron and photon absorbed dose in mixed neutron-photon beams. The accuracy in dose measurements can be increased by use of a computer. Additionally the number of data needed to store a glow curve can be reduced from 240 to 24 by fitting a sum of Gauss functions to the measured glow curve.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Meissner</LastName>
<ForeName>P</ForeName>
<Initials>P</Initials>
</Author>
</AuthorList>
<Language>ger</Language>
<PublicationTypeList>
<PublicationType UI="D004740">English Abstract</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<VernacularTitle>Digitale Erfassung der Glowkurven von TLD-300-Detektoren und Datenreduktion durch Anpassung einer Summe von Gaussfunktionen an die Messwerte.</VernacularTitle>
</Article>
<MedlineJournalInfo>
<Country>GERMANY, WEST</Country>
<MedlineTA>Strahlentherapie</MedlineTA>
<NlmUniqueID>1260024</NlmUniqueID>
<ISSNLinking>0039-2073</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>8RKC5ATI4P</RegistryNumber>
<NameOfSubstance UI="D013932">Thulium</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>O3B55K4YKI</RegistryNumber>
<NameOfSubstance UI="D002124">Calcium Fluoride</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D002124">Calcium Fluoride</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000528">radiation effects</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D003201">Computers</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005214">Fast Neutrons</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008433">Mathematics</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011827">Radiation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D011829">Radiation Dosage</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013816">Thermodynamics</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013819">Thermoluminescent Dosimetry</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013932">Thulium</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000528">radiation effects</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1985</Year>
<Month>2</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1985</Year>
<Month>2</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1985</Year>
<Month>2</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">3975938</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Terre/explor/ThuliumV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000840 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000840 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Terre
   |area=    ThuliumV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:3975938
   |texte=   [Digital recording of glow curves of the TLD-300 thermoluminescent dosimetry detector by adaptation of a sum of Gauss function to the measured values].
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:3975938" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a ThuliumV1 

Wicri

This area was generated with Dilib version V0.6.21.
Data generation: Thu May 12 08:27:09 2016. Site generation: Thu Mar 7 22:33:44 2024