Abstract
We report on the use of a thulium-fiber-pumped holmium-based emitter in a coherent differential absorption lidar (CDIAL) experiment for high time and space resolution of CO(2) absorption field in the atmosphere. The 2-μm high-power dual-wavelength single-mode Q-switched Ho:YLF oscillator delivers 10-mJ pulses with a duration of 40 ns at 2 kHz. Both short pulse duration and high repetition rate were chosen to increase the DIAL precision and time and space resolution in coherent detection. The CDIAL provides 150-m range and 15-min time-resolved CO(2) absorption coefficient with a calculated instrumental error of 0.5% at 500 m and less than 2% at 1 km. Dry-air CO(2) mixing ratio estimates from the DIAL system are compared with simultaneous in situ gas analyzer measurements during a 20-h-long experiment.
PubMed: 26125375
Affiliations:
Links toward previous steps (curation, corpus...)
Links to Exploration step
pubmed:26125375Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">2-μm Ho emitter-based coherent DIAL for CO(2) profiling in the atmosphere.</title>
<author><name sortKey="Gibert, F" sort="Gibert, F" uniqKey="Gibert F" first="F" last="Gibert">F. Gibert</name>
</author>
<author><name sortKey="Edouart, D" sort="Edouart, D" uniqKey="Edouart D" first="D" last="Edouart">D. Edouart</name>
</author>
<author><name sortKey="Cenac, C" sort="Cenac, C" uniqKey="Cenac C" first="C" last="Cénac">C. Cénac</name>
</author>
<author><name sortKey="Le Mounier, F" sort="Le Mounier, F" uniqKey="Le Mounier F" first="F" last="Le Mounier">F. Le Mounier</name>
</author>
<author><name sortKey="Dumas, A" sort="Dumas, A" uniqKey="Dumas A" first="A" last="Dumas">A. Dumas</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2015">2015</date>
<idno type="RBID">pubmed:26125375</idno>
<idno type="pmid">26125375</idno>
<idno type="wicri:Area/PubMed/Corpus">000069</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000069</idno>
<idno type="wicri:Area/PubMed/Curation">000069</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000069</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000069</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000069</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">2-μm Ho emitter-based coherent DIAL for CO(2) profiling in the atmosphere.</title>
<author><name sortKey="Gibert, F" sort="Gibert, F" uniqKey="Gibert F" first="F" last="Gibert">F. Gibert</name>
</author>
<author><name sortKey="Edouart, D" sort="Edouart, D" uniqKey="Edouart D" first="D" last="Edouart">D. Edouart</name>
</author>
<author><name sortKey="Cenac, C" sort="Cenac, C" uniqKey="Cenac C" first="C" last="Cénac">C. Cénac</name>
</author>
<author><name sortKey="Le Mounier, F" sort="Le Mounier, F" uniqKey="Le Mounier F" first="F" last="Le Mounier">F. Le Mounier</name>
</author>
<author><name sortKey="Dumas, A" sort="Dumas, A" uniqKey="Dumas A" first="A" last="Dumas">A. Dumas</name>
</author>
</analytic>
<series><title level="j">Optics letters</title>
<idno type="eISSN">1539-4794</idno>
<imprint><date when="2015" type="published">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">We report on the use of a thulium-fiber-pumped holmium-based emitter in a coherent differential absorption lidar (CDIAL) experiment for high time and space resolution of CO(2) absorption field in the atmosphere. The 2-μm high-power dual-wavelength single-mode Q-switched Ho:YLF oscillator delivers 10-mJ pulses with a duration of 40 ns at 2 kHz. Both short pulse duration and high repetition rate were chosen to increase the DIAL precision and time and space resolution in coherent detection. The CDIAL provides 150-m range and 15-min time-resolved CO(2) absorption coefficient with a calculated instrumental error of 0.5% at 500 m and less than 2% at 1 km. Dry-air CO(2) mixing ratio estimates from the DIAL system are compared with simultaneous in situ gas analyzer measurements during a 20-h-long experiment.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="PubMed-not-MEDLINE"><PMID Version="1">26125375</PMID>
<DateCreated><Year>2015</Year>
<Month>07</Month>
<Day>01</Day>
</DateCreated>
<DateCompleted><Year>2015</Year>
<Month>09</Month>
<Day>02</Day>
</DateCompleted>
<Article PubModel="Print"><Journal><ISSN IssnType="Electronic">1539-4794</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>40</Volume>
<Issue>13</Issue>
<PubDate><Year>2015</Year>
<Month>Jul</Month>
<Day>1</Day>
</PubDate>
</JournalIssue>
<Title>Optics letters</Title>
<ISOAbbreviation>Opt Lett</ISOAbbreviation>
</Journal>
<ArticleTitle>2-μm Ho emitter-based coherent DIAL for CO(2) profiling in the atmosphere.</ArticleTitle>
<Pagination><MedlinePgn>3093-6</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1364/OL.40.003093</ELocationID>
<Abstract><AbstractText>We report on the use of a thulium-fiber-pumped holmium-based emitter in a coherent differential absorption lidar (CDIAL) experiment for high time and space resolution of CO(2) absorption field in the atmosphere. The 2-μm high-power dual-wavelength single-mode Q-switched Ho:YLF oscillator delivers 10-mJ pulses with a duration of 40 ns at 2 kHz. Both short pulse duration and high repetition rate were chosen to increase the DIAL precision and time and space resolution in coherent detection. The CDIAL provides 150-m range and 15-min time-resolved CO(2) absorption coefficient with a calculated instrumental error of 0.5% at 500 m and less than 2% at 1 km. Dry-air CO(2) mixing ratio estimates from the DIAL system are compared with simultaneous in situ gas analyzer measurements during a 20-h-long experiment.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Gibert</LastName>
<ForeName>F</ForeName>
<Initials>F</Initials>
</Author>
<Author ValidYN="Y"><LastName>Edouart</LastName>
<ForeName>D</ForeName>
<Initials>D</Initials>
</Author>
<Author ValidYN="Y"><LastName>Cénac</LastName>
<ForeName>C</ForeName>
<Initials>C</Initials>
</Author>
<Author ValidYN="Y"><LastName>Le Mounier</LastName>
<ForeName>F</ForeName>
<Initials>F</Initials>
</Author>
<Author ValidYN="Y"><LastName>Dumas</LastName>
<ForeName>A</ForeName>
<Initials>A</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>Opt Lett</MedlineTA>
<NlmUniqueID>7708433</NlmUniqueID>
<ISSNLinking>0146-9592</ISSNLinking>
</MedlineJournalInfo>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="entrez"><Year>2015</Year>
<Month>7</Month>
<Day>1</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2015</Year>
<Month>7</Month>
<Day>1</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2015</Year>
<Month>7</Month>
<Day>1</Day>
<Hour>6</Hour>
<Minute>1</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pii">321172</ArticleId>
<ArticleId IdType="pubmed">26125375</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations><list></list>
<tree><noCountry><name sortKey="Cenac, C" sort="Cenac, C" uniqKey="Cenac C" first="C" last="Cénac">C. Cénac</name>
<name sortKey="Dumas, A" sort="Dumas, A" uniqKey="Dumas A" first="A" last="Dumas">A. Dumas</name>
<name sortKey="Edouart, D" sort="Edouart, D" uniqKey="Edouart D" first="D" last="Edouart">D. Edouart</name>
<name sortKey="Gibert, F" sort="Gibert, F" uniqKey="Gibert F" first="F" last="Gibert">F. Gibert</name>
<name sortKey="Le Mounier, F" sort="Le Mounier, F" uniqKey="Le Mounier F" first="F" last="Le Mounier">F. Le Mounier</name>
</noCountry>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Terre/explor/ThuliumV1/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000120 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 000120 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Terre |area= ThuliumV1 |flux= PubMed |étape= Checkpoint |type= RBID |clé= pubmed:26125375 |texte= 2-μm Ho emitter-based coherent DIAL for CO(2) profiling in the atmosphere. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i -Sk "pubmed:26125375" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd \ | NlmPubMed2Wicri -a ThuliumV1
This area was generated with Dilib version V0.6.21. |