Wavelength resolved intracavity measurement of the cross sections of a Tm-doped fiber.

Identifieur interne : 000239 ( Ncbi/Merge ); précédent : 000238; suivant : 000240

Wavelength resolved intracavity measurement of the cross sections of a Tm-doped fiber.

Auteurs : Martin Engelbrecht [Allemagne] ; Frithjof Haxsen ; Dieter Wandt ; Dietmar Kracht

Source :

RBID : pubmed:18542239

Descripteurs français

English descriptors

Abstract

The wavelength dependent measurement of the relaxation oscillation frequency in a laser oscillator allows the study of the three- and four-level nature of the active material. Accordingly we present a tunable thulium doped fiber laser that covers the transition from three- to four-level operation at 2025 nm, characterized by the vanishing occupation of the terminal laser level. The laser is tunable from 1864 nm to 2075 nm with a linewidth below 0.3 nm. A maximum output power of 3.8 W at 1930 nm was achieved with a slope efficiency of 33.6% and an absorbed pump power of 17.5 W. Absorption and emission cross sections were derived over the tuning range by an intracavity measurement method.

PubMed: 18542239

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:18542239

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Wavelength resolved intracavity measurement of the cross sections of a Tm-doped fiber.</title>
<author>
<name sortKey="Engelbrecht, Martin" sort="Engelbrecht, Martin" uniqKey="Engelbrecht M" first="Martin" last="Engelbrecht">Martin Engelbrecht</name>
<affiliation wicri:level="3">
<nlm:affiliation>Laser Zentrum Hannover e.V., Hollerithallee 8 30419 Hannover, Germany. m.engelbrecht@lzh.de</nlm:affiliation>
<country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Laser Zentrum Hannover e.V., Hollerithallee 8 30419 Hannover</wicri:regionArea>
<placeName>
<region type="land" nuts="2">Basse-Saxe</region>
<settlement type="city">Hanovre</settlement>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Haxsen, Frithjof" sort="Haxsen, Frithjof" uniqKey="Haxsen F" first="Frithjof" last="Haxsen">Frithjof Haxsen</name>
</author>
<author>
<name sortKey="Wandt, Dieter" sort="Wandt, Dieter" uniqKey="Wandt D" first="Dieter" last="Wandt">Dieter Wandt</name>
</author>
<author>
<name sortKey="Kracht, Dietmar" sort="Kracht, Dietmar" uniqKey="Kracht D" first="Dietmar" last="Kracht">Dietmar Kracht</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2008">2008</date>
<idno type="RBID">pubmed:18542239</idno>
<idno type="pmid">18542239</idno>
<idno type="wicri:Area/PubMed/Corpus">000580</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000580</idno>
<idno type="wicri:Area/PubMed/Curation">000580</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000580</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000580</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000580</idno>
<idno type="wicri:Area/Ncbi/Merge">000239</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Wavelength resolved intracavity measurement of the cross sections of a Tm-doped fiber.</title>
<author>
<name sortKey="Engelbrecht, Martin" sort="Engelbrecht, Martin" uniqKey="Engelbrecht M" first="Martin" last="Engelbrecht">Martin Engelbrecht</name>
<affiliation wicri:level="3">
<nlm:affiliation>Laser Zentrum Hannover e.V., Hollerithallee 8 30419 Hannover, Germany. m.engelbrecht@lzh.de</nlm:affiliation>
<country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Laser Zentrum Hannover e.V., Hollerithallee 8 30419 Hannover</wicri:regionArea>
<placeName>
<region type="land" nuts="2">Basse-Saxe</region>
<settlement type="city">Hanovre</settlement>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Haxsen, Frithjof" sort="Haxsen, Frithjof" uniqKey="Haxsen F" first="Frithjof" last="Haxsen">Frithjof Haxsen</name>
</author>
<author>
<name sortKey="Wandt, Dieter" sort="Wandt, Dieter" uniqKey="Wandt D" first="Dieter" last="Wandt">Dieter Wandt</name>
</author>
<author>
<name sortKey="Kracht, Dietmar" sort="Kracht, Dietmar" uniqKey="Kracht D" first="Dietmar" last="Kracht">Dietmar Kracht</name>
</author>
</analytic>
<series>
<title level="j">Optics express</title>
<idno type="eISSN">1094-4087</idno>
<imprint>
<date when="2008" type="published">2008</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Equipment Design</term>
<term>Equipment Failure Analysis</term>
<term>Fiber Optic Technology (instrumentation)</term>
<term>Lasers</term>
<term>Oscillometry (instrumentation)</term>
<term>Radiometry</term>
<term>Thulium (chemistry)</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Analyse de panne d'appareillage</term>
<term>Conception d'appareillage</term>
<term>Lasers</term>
<term>Oscillométrie (instrumentation)</term>
<term>Radiométrie</term>
<term>Technologie des fibres optiques (instrumentation)</term>
<term>Thulium ()</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="chemistry" xml:lang="en">
<term>Thulium</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Fiber Optic Technology</term>
<term>Oscillometry</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Equipment Design</term>
<term>Equipment Failure Analysis</term>
<term>Lasers</term>
<term>Radiometry</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Analyse de panne d'appareillage</term>
<term>Conception d'appareillage</term>
<term>Lasers</term>
<term>Oscillométrie</term>
<term>Radiométrie</term>
<term>Technologie des fibres optiques</term>
<term>Thulium</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The wavelength dependent measurement of the relaxation oscillation frequency in a laser oscillator allows the study of the three- and four-level nature of the active material. Accordingly we present a tunable thulium doped fiber laser that covers the transition from three- to four-level operation at 2025 nm, characterized by the vanishing occupation of the terminal laser level. The laser is tunable from 1864 nm to 2075 nm with a linewidth below 0.3 nm. A maximum output power of 3.8 W at 1930 nm was achieved with a slope efficiency of 33.6% and an absorbed pump power of 17.5 W. Absorption and emission cross sections were derived over the tuning range by an intracavity measurement method.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">18542239</PMID>
<DateCreated>
<Year>2008</Year>
<Month>06</Month>
<Day>10</Day>
</DateCreated>
<DateCompleted>
<Year>2008</Year>
<Month>08</Month>
<Day>21</Day>
</DateCompleted>
<DateRevised>
<Year>2013</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1094-4087</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>16</Volume>
<Issue>3</Issue>
<PubDate>
<Year>2008</Year>
<Month>Feb</Month>
<Day>4</Day>
</PubDate>
</JournalIssue>
<Title>Optics express</Title>
<ISOAbbreviation>Opt Express</ISOAbbreviation>
</Journal>
<ArticleTitle>Wavelength resolved intracavity measurement of the cross sections of a Tm-doped fiber.</ArticleTitle>
<Pagination>
<MedlinePgn>1610-5</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>The wavelength dependent measurement of the relaxation oscillation frequency in a laser oscillator allows the study of the three- and four-level nature of the active material. Accordingly we present a tunable thulium doped fiber laser that covers the transition from three- to four-level operation at 2025 nm, characterized by the vanishing occupation of the terminal laser level. The laser is tunable from 1864 nm to 2075 nm with a linewidth below 0.3 nm. A maximum output power of 3.8 W at 1930 nm was achieved with a slope efficiency of 33.6% and an absorbed pump power of 17.5 W. Absorption and emission cross sections were derived over the tuning range by an intracavity measurement method.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Engelbrecht</LastName>
<ForeName>Martin</ForeName>
<Initials>M</Initials>
<AffiliationInfo>
<Affiliation>Laser Zentrum Hannover e.V., Hollerithallee 8 30419 Hannover, Germany. m.engelbrecht@lzh.de</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Haxsen</LastName>
<ForeName>Frithjof</ForeName>
<Initials>F</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Wandt</LastName>
<ForeName>Dieter</ForeName>
<Initials>D</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Kracht</LastName>
<ForeName>Dietmar</ForeName>
<Initials>D</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Opt Express</MedlineTA>
<NlmUniqueID>101137103</NlmUniqueID>
<ISSNLinking>1094-4087</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>8RKC5ATI4P</RegistryNumber>
<NameOfSubstance UI="D013932">Thulium</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D004867">Equipment Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019544">Equipment Failure Analysis</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005336">Fiber Optic Technology</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007834">Lasers</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D009991">Oscillometry</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011874">Radiometry</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013932">Thulium</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000737">chemistry</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2008</Year>
<Month>6</Month>
<Day>11</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2008</Year>
<Month>8</Month>
<Day>22</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2008</Year>
<Month>6</Month>
<Day>11</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pii">149926</ArticleId>
<ArticleId IdType="pubmed">18542239</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Allemagne</li>
</country>
<region>
<li>Basse-Saxe</li>
</region>
<settlement>
<li>Hanovre</li>
</settlement>
</list>
<tree>
<noCountry>
<name sortKey="Haxsen, Frithjof" sort="Haxsen, Frithjof" uniqKey="Haxsen F" first="Frithjof" last="Haxsen">Frithjof Haxsen</name>
<name sortKey="Kracht, Dietmar" sort="Kracht, Dietmar" uniqKey="Kracht D" first="Dietmar" last="Kracht">Dietmar Kracht</name>
<name sortKey="Wandt, Dieter" sort="Wandt, Dieter" uniqKey="Wandt D" first="Dieter" last="Wandt">Dieter Wandt</name>
</noCountry>
<country name="Allemagne">
<region name="Basse-Saxe">
<name sortKey="Engelbrecht, Martin" sort="Engelbrecht, Martin" uniqKey="Engelbrecht M" first="Martin" last="Engelbrecht">Martin Engelbrecht</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Terre/explor/ThuliumV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000239 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 000239 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Terre
   |area=    ThuliumV1
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:18542239
   |texte=   Wavelength resolved intracavity measurement of the cross sections of a Tm-doped fiber.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:18542239" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a ThuliumV1 

Wicri

This area was generated with Dilib version V0.6.21.
Data generation: Thu May 12 08:27:09 2016. Site generation: Thu Mar 7 22:33:44 2024