Diode-pumped thulium-doped zirconium fluoride fibre as a fluorescent source for water sensing
Identifieur interne : 003061 ( Main/Exploration ); précédent : 003060; suivant : 003062Diode-pumped thulium-doped zirconium fluoride fibre as a fluorescent source for water sensing
Auteurs : F. J. Mcaleavey [Irlande (pays)] ; B. D. MaccraithSource :
- Electronics Letters [ 0013-5194 ] ; 1995.
Descripteurs français
- Pascal (Inist)
- Application, Capteur humidité, Capteur mesure, Capteur optique, Dopage semiconducteur, Etude expérimentale, Fibre optique, Fluorescence, Méthode mesure, Thulium composé, Laser semiconducteur, Absorption onde électromagnétique, Spectromètre IR, Indice réfraction, Source lumineuse, Fibre optique, Expérience.
English descriptors
- KwdEn :
- Application, Declad optical fibre, Electromagnetic wave absorption, Evanescent wave absorption system, Experimental study, Experiments, Fluorescence, Fluorescent source, Humidity sensors, Infrared spectrometers, Light sources, Measurement method, Measurement sensor, Mixing water, Moisture sensor, Numerical aperture, Optical fibers, Optical sensors, Refractive index, Semiconductor doping, Semiconductor lasers, Thulium compounds, Water concentration, Water measurement, Water sensing.
Abstract
Tm3+-doped zirconium fluoride fibre pumped with a low-cost diode laser at 785nm is shown to function as a useful source for water or humidity sensing. The near-IR fluorescent emission band centred at 1.47μm exhibits considerable overlap with an absorption band of H2O. Using a variable path-length cell and the residual pump signal as a reference, the fluorescent fibre source is shown to enable measurement of path lengths as low as 1 μm in liquid water. In addition, using a declad fibre as an evanescent-wave absorption probe, the feasibility of measuring water concentrations in other liquids is demonstrated.
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Pascal, to step Corpus: 001540
- to stream Pascal, to step Curation: 001540
- to stream Pascal, to step Checkpoint: 001629
- to stream Main, to step Merge: 003310
- to stream Pascal, to step Corpus: 001543
- to stream Pascal, to step Curation: 001543
- to stream Pascal, to step Checkpoint: 001628
- to stream Main, to step Merge: 003309
- to stream Main, to step Curation: 003061
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en" level="a">Diode-pumped thulium-doped zirconium fluoride fibre as a fluorescent source for water sensing</title>
<author><name sortKey="Mcaleavey, F J" sort="Mcaleavey, F J" uniqKey="Mcaleavey F" first="F. J." last="Mcaleavey">F. J. Mcaleavey</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Dublin City Univ</s1>
<s2>Dublin</s2>
<s3>IRL</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
<country>Irlande (pays)</country>
<wicri:noRegion>Dublin City Univ</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Maccraith, B D" sort="Maccraith, B D" uniqKey="Maccraith B" first="B. D." last="Maccraith">B. D. Maccraith</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">INIST</idno>
<idno type="inist">95-0505519</idno>
<date when="1995">1995</date>
<idno type="stanalyst">PASCAL 95-0505519 EI</idno>
<idno type="RBID">Pascal:95-0505519</idno>
<idno type="wicri:Area/Pascal/Corpus">001540</idno>
<idno type="wicri:Area/Pascal/Curation">001540</idno>
<idno type="wicri:Area/Pascal/Checkpoint">001629</idno>
<idno type="wicri:explorRef" wicri:stream="Pascal" wicri:step="Checkpoint">001629</idno>
<idno type="wicri:doubleKey">0013-5194:1995:Mcaleavey F:diode:pumped:thulium</idno>
<idno type="wicri:Area/Main/Merge">003310</idno>
<idno type="wicri:source">INIST</idno>
<idno type="RBID">Pascal:95-0495539</idno>
<idno type="wicri:Area/Pascal/Corpus">001543</idno>
<idno type="wicri:Area/Pascal/Curation">001543</idno>
<idno type="wicri:Area/Pascal/Checkpoint">001628</idno>
<idno type="wicri:explorRef" wicri:stream="Pascal" wicri:step="Checkpoint">001628</idno>
<idno type="wicri:doubleKey">0013-5194:1995:Mcaleavey F:diode:pumped:thulium</idno>
<idno type="wicri:Area/Main/Merge">003309</idno>
<idno type="wicri:Area/Main/Curation">003061</idno>
<idno type="wicri:Area/Main/Exploration">003061</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a">Diode-pumped thulium-doped zirconium fluoride fibre as a fluorescent source for water sensing</title>
<author><name sortKey="Mcaleavey, F J" sort="Mcaleavey, F J" uniqKey="Mcaleavey F" first="F. J." last="Mcaleavey">F. J. Mcaleavey</name>
<affiliation wicri:level="1"><inist:fA14 i1="01"><s1>Dublin City Univ</s1>
<s2>Dublin</s2>
<s3>IRL</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
<country>Irlande (pays)</country>
<wicri:noRegion>Dublin City Univ</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Maccraith, B D" sort="Maccraith, B D" uniqKey="Maccraith B" first="B. D." last="Maccraith">B. D. Maccraith</name>
</author>
</analytic>
<series><title level="j" type="main">Electronics Letters</title>
<title level="j" type="abbreviated">Electron Lett</title>
<idno type="ISSN">0013-5194</idno>
<imprint><date when="1995">1995</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><title level="j" type="main">Electronics Letters</title>
<title level="j" type="abbreviated">Electron Lett</title>
<idno type="ISSN">0013-5194</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Application</term>
<term>Declad optical fibre</term>
<term>Electromagnetic wave absorption</term>
<term>Evanescent wave absorption system</term>
<term>Experimental study</term>
<term>Experiments</term>
<term>Fluorescence</term>
<term>Fluorescent source</term>
<term>Humidity sensors</term>
<term>Infrared spectrometers</term>
<term>Light sources</term>
<term>Measurement method</term>
<term>Measurement sensor</term>
<term>Mixing water</term>
<term>Moisture sensor</term>
<term>Numerical aperture</term>
<term>Optical fibers</term>
<term>Optical sensors</term>
<term>Refractive index</term>
<term>Semiconductor doping</term>
<term>Semiconductor lasers</term>
<term>Thulium compounds</term>
<term>Water concentration</term>
<term>Water measurement</term>
<term>Water sensing</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr"><term>Application</term>
<term>Capteur humidité</term>
<term>Capteur mesure</term>
<term>Capteur optique</term>
<term>Dopage semiconducteur</term>
<term>Etude expérimentale</term>
<term>Fibre optique</term>
<term>Fluorescence</term>
<term>Méthode mesure</term>
<term>Thulium composé</term>
<term>Laser semiconducteur</term>
<term>Absorption onde électromagnétique</term>
<term>Spectromètre IR</term>
<term>Indice réfraction</term>
<term>Source lumineuse</term>
<term>Fibre optique</term>
<term>Expérience</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Tm<sup>3+</sup>
-doped zirconium fluoride fibre pumped with a low-cost diode laser at 785nm is shown to function as a useful source for water or humidity sensing. The near-IR fluorescent emission band centred at 1.47μm exhibits considerable overlap with an absorption band of H<sub>2</sub>
O. Using a variable path-length cell and the residual pump signal as a reference, the fluorescent fibre source is shown to enable measurement of path lengths as low as 1 μm in liquid water. In addition, using a declad fibre as an evanescent-wave absorption probe, the feasibility of measuring water concentrations in other liquids is demonstrated.</div>
</front>
</TEI>
<affiliations><list><country><li>Irlande (pays)</li>
</country>
</list>
<tree><noCountry><name sortKey="Maccraith, B D" sort="Maccraith, B D" uniqKey="Maccraith B" first="B. D." last="Maccraith">B. D. Maccraith</name>
</noCountry>
<country name="Irlande (pays)"><noRegion><name sortKey="Mcaleavey, F J" sort="Mcaleavey, F J" uniqKey="Mcaleavey F" first="F. J." last="Mcaleavey">F. J. Mcaleavey</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Terre/explor/ThuliumV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003061 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 003061 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Terre |area= ThuliumV1 |flux= Main |étape= Exploration |type= RBID |clé= Pascal:95-0505519 |texte= Diode-pumped thulium-doped zirconium fluoride fibre as a fluorescent source for water sensing }}
This area was generated with Dilib version V0.6.21. |