New NIST-traceable standards for calibration and validation of DSC

Identifieur interne : 008769 ( Main/Repository ); précédent : 008768; suivant : 008770

New NIST-traceable standards for calibration and validation of DSC

Auteurs : RBID : Pascal:07-0022552

Descripteurs français

English descriptors

Abstract

Several reference materials and associated reference values have been recommended for the purposes of calibration and/or validation of differential scanning calorimetry (DSC). However, issues of available sample purity, reference-property value accuracy, and potential undesired reactions between reference materials and the materials used for sample pans have not been considered sufficiently in some of the recommendations of property values for the materials. These limitations attenuate greatly the usefulness of many of these reference material recommendations. Indeed, the state of uncertainty regarding true reference property values can be shown to be a limiting factor in the uncertainty of measurements made with DSC. NIST has certified the temperatures and enthalpies of fusion of two new Standard Reference Materials, SRMs 2234 and 2235, in order to help alleviate some of the difficulty.

Links toward previous steps (curation, corpus...)


Links to Exploration step

Pascal:07-0022552

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">New NIST-traceable standards for calibration and validation of DSC</title>
<author>
<name sortKey="Archer, D G" uniqKey="Archer D">D. G. Archer</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Physical and Chemical Properties Division, National Institute of Standards and Technology, 100 Bureau Drive, MS 8380</s1>
<s2>Gaithersburg, MD 20899-8380</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName>
<region type="state">État du Mississippi</region>
</placeName>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="inist">07-0022552</idno>
<date when="2006">2006</date>
<idno type="stanalyst">PASCAL 07-0022552 INIST</idno>
<idno type="RBID">Pascal:07-0022552</idno>
<idno type="wicri:Area/Main/Corpus">008459</idno>
<idno type="wicri:Area/Main/Repository">008769</idno>
</publicationStmt>
<seriesStmt>
<idno type="ISSN">1388-6150</idno>
<title level="j" type="abbreviated">J. therm. anal. calorim.</title>
<title level="j" type="main">Journal of thermal analysis and calorimetry</title>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Bismuth</term>
<term>Calibration</term>
<term>Certification</term>
<term>Differential scanning calorimetry</term>
<term>Gallium</term>
<term>Indium</term>
<term>Reference material</term>
<term>Standard</term>
<term>Thermal analysis</term>
<term>Tin</term>
<term>Traceability</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Etalonnage</term>
<term>Calorimétrie différentielle balayage</term>
<term>Bismuth</term>
<term>Gallium</term>
<term>Indium</term>
<term>Etalon</term>
<term>Matériau référence</term>
<term>Etain</term>
<term>Certification</term>
<term>Traçabilité</term>
<term>Analyse thermique</term>
</keywords>
<keywords scheme="Wicri" type="concept" xml:lang="fr">
<term>Bismuth</term>
<term>Traçabilité</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Several reference materials and associated reference values have been recommended for the purposes of calibration and/or validation of differential scanning calorimetry (DSC). However, issues of available sample purity, reference-property value accuracy, and potential undesired reactions between reference materials and the materials used for sample pans have not been considered sufficiently in some of the recommendations of property values for the materials. These limitations attenuate greatly the usefulness of many of these reference material recommendations. Indeed, the state of uncertainty regarding true reference property values can be shown to be a limiting factor in the uncertainty of measurements made with DSC. NIST has certified the temperatures and enthalpies of fusion of two new Standard Reference Materials, SRMs 2234 and 2235, in order to help alleviate some of the difficulty.</div>
</front>
</TEI>
<inist>
<standard h6="B">
<pA>
<fA01 i1="01" i2="1">
<s0>1388-6150</s0>
</fA01>
<fA03 i2="1">
<s0>J. therm. anal. calorim.</s0>
</fA03>
<fA05>
<s2>85</s2>
</fA05>
<fA06>
<s2>1</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG">
<s1>New NIST-traceable standards for calibration and validation of DSC</s1>
</fA08>
<fA09 i1="01" i2="1" l="ENG">
<s1>33rd North American Thermal Analysis Society Conference: NATAS 2005, September 19-21, 2005, Universal City, California</s1>
</fA09>
<fA11 i1="01" i2="1">
<s1>ARCHER (D. G.)</s1>
</fA11>
<fA12 i1="01" i2="1">
<s1>RICH (Michael J.)</s1>
<s9>ed.</s9>
</fA12>
<fA14 i1="01">
<s1>Physical and Chemical Properties Division, National Institute of Standards and Technology, 100 Bureau Drive, MS 8380</s1>
<s2>Gaithersburg, MD 20899-8380</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
</fA14>
<fA15 i1="01">
<s1>Composite Materials and Structure Center, Michigan State University</s1>
<s3>USA</s3>
<sZ>1 aut.</sZ>
</fA15>
<fA18 i1="01" i2="1">
<s1>North American Analysis Society</s1>
<s3>USA</s3>
<s9>org-cong.</s9>
</fA18>
<fA20>
<s1>131-134</s1>
</fA20>
<fA21>
<s1>2006</s1>
</fA21>
<fA23 i1="01">
<s0>ENG</s0>
</fA23>
<fA43 i1="01">
<s1>INIST</s1>
<s2>6367</s2>
<s5>354000157028800220</s5>
</fA43>
<fA44>
<s0>0000</s0>
<s1>© 2007 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45>
<s0>9 ref.</s0>
</fA45>
<fA47 i1="01" i2="1">
<s0>07-0022552</s0>
</fA47>
<fA60>
<s1>P</s1>
<s2>C</s2>
</fA60>
<fA61>
<s0>A</s0>
</fA61>
<fA64 i1="01" i2="1">
<s0>Journal of thermal analysis and calorimetry</s0>
</fA64>
<fA66 i1="01">
<s0>NLD</s0>
</fA66>
<fC01 i1="01" l="ENG">
<s0>Several reference materials and associated reference values have been recommended for the purposes of calibration and/or validation of differential scanning calorimetry (DSC). However, issues of available sample purity, reference-property value accuracy, and potential undesired reactions between reference materials and the materials used for sample pans have not been considered sufficiently in some of the recommendations of property values for the materials. These limitations attenuate greatly the usefulness of many of these reference material recommendations. Indeed, the state of uncertainty regarding true reference property values can be shown to be a limiting factor in the uncertainty of measurements made with DSC. NIST has certified the temperatures and enthalpies of fusion of two new Standard Reference Materials, SRMs 2234 and 2235, in order to help alleviate some of the difficulty.</s0>
</fC01>
<fC02 i1="01" i2="X">
<s0>001C04F</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE">
<s0>Etalonnage</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG">
<s0>Calibration</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA">
<s0>Contraste</s0>
<s5>01</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE">
<s0>Calorimétrie différentielle balayage</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG">
<s0>Differential scanning calorimetry</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA">
<s0>Análisis calorimétrico barrido exploración</s0>
<s5>02</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE">
<s0>Bismuth</s0>
<s2>NC</s2>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG">
<s0>Bismuth</s0>
<s2>NC</s2>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA">
<s0>Bismuto</s0>
<s2>NC</s2>
<s5>03</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE">
<s0>Gallium</s0>
<s2>NC</s2>
<s2>FX</s2>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG">
<s0>Gallium</s0>
<s2>NC</s2>
<s2>FX</s2>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA">
<s0>Galio</s0>
<s2>NC</s2>
<s2>FX</s2>
<s5>04</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE">
<s0>Indium</s0>
<s2>NC</s2>
<s5>05</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG">
<s0>Indium</s0>
<s2>NC</s2>
<s5>05</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA">
<s0>Indio</s0>
<s2>NC</s2>
<s5>05</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE">
<s0>Etalon</s0>
<s5>06</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG">
<s0>Standard</s0>
<s5>06</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA">
<s0>Marco</s0>
<s5>06</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE">
<s0>Matériau référence</s0>
<s5>07</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG">
<s0>Reference material</s0>
<s5>07</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA">
<s0>Material referencia</s0>
<s5>07</s5>
</fC03>
<fC03 i1="08" i2="X" l="FRE">
<s0>Etain</s0>
<s2>NC</s2>
<s2>FX</s2>
<s5>08</s5>
</fC03>
<fC03 i1="08" i2="X" l="ENG">
<s0>Tin</s0>
<s2>NC</s2>
<s2>FX</s2>
<s5>08</s5>
</fC03>
<fC03 i1="08" i2="X" l="SPA">
<s0>Estaño</s0>
<s2>NC</s2>
<s2>FX</s2>
<s5>08</s5>
</fC03>
<fC03 i1="09" i2="X" l="FRE">
<s0>Certification</s0>
<s5>09</s5>
</fC03>
<fC03 i1="09" i2="X" l="ENG">
<s0>Certification</s0>
<s5>09</s5>
</fC03>
<fC03 i1="09" i2="X" l="SPA">
<s0>Certificación</s0>
<s5>09</s5>
</fC03>
<fC03 i1="10" i2="X" l="FRE">
<s0>Traçabilité</s0>
<s5>10</s5>
</fC03>
<fC03 i1="10" i2="X" l="ENG">
<s0>Traceability</s0>
<s5>10</s5>
</fC03>
<fC03 i1="10" i2="X" l="SPA">
<s0>Rastreabilidad</s0>
<s5>10</s5>
</fC03>
<fC03 i1="11" i2="X" l="FRE">
<s0>Analyse thermique</s0>
<s5>32</s5>
</fC03>
<fC03 i1="11" i2="X" l="ENG">
<s0>Thermal analysis</s0>
<s5>32</s5>
</fC03>
<fC03 i1="11" i2="X" l="SPA">
<s0>Análisis térmico</s0>
<s5>32</s5>
</fC03>
<fN21>
<s1>010</s1>
</fN21>
</pA>
<pR>
<fA30 i1="01" i2="1" l="ENG">
<s1>NATAS 2005 North American Thermal Analysis Society Conference</s1>
<s2>33</s2>
<s3>Universal City, California USA</s3>
<s4>2005-09-19</s4>
</fA30>
</pR>
</standard>
</inist>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=IndiumV3/Data/Main/Repository
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 008769 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Repository/biblio.hfd -nk 008769 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=   *** parameter Area/wikiCode missing *** 
   |area=    IndiumV3
   |flux=    Main
   |étape=   Repository
   |type=    RBID
   |clé=     Pascal:07-0022552
   |texte=   New NIST-traceable standards for calibration and validation of DSC
}}

Wicri

This area was generated with Dilib version V0.5.77.
Data generation: Mon Jun 9 10:27:54 2014. Site generation: Thu Mar 7 16:19:59 2024