Serveur d'exploration sur l'Indium

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

The beam divergence of an indium LMIS at a distance of 50 μm as determined by plasma diagnostic measurements.

Identifieur interne : 001092 ( Main/Exploration ); précédent : 001091; suivant : 001093

The beam divergence of an indium LMIS at a distance of 50 μm as determined by plasma diagnostic measurements.

Auteurs : RBID : pubmed:21740859

Abstract

The current-dependent beam divergence at a distance of 50 μm from an indium-liquid metal ion source is derived from experimental data obtained by measuring the beam spread with a 3D Plasma diagnostic system at a distance of 10 cm from the needle tip. The observed relationship between emission current and beam divergence in vicinity of the emitting needle is used to design a focusing electrode for a field-emission electric propulsion thruster operating at currents up to 150 μA. Another application involves focused ion beam columns which may choose to forego a beam-limiting aperture, such as LMIS-based rapid machining tools with large beam currents.

DOI: 10.1016/j.ultramic.2011.01.040
PubMed: 21740859

Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The beam divergence of an indium LMIS at a distance of 50 μm as determined by plasma diagnostic measurements.</title>
<author>
<name sortKey="Vasiljevich, I" uniqKey="Vasiljevich I">I Vasiljevich</name>
<affiliation wicri:level="1">
<nlm:affiliation>FOTEC, Wiener Neustadt, Austria. vasiljevich@fotec.at</nlm:affiliation>
<country xml:lang="fr">Autriche</country>
<wicri:regionArea>FOTEC, Wiener Neustadt</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Tajmar, M" uniqKey="Tajmar M">M Tajmar</name>
</author>
</titleStmt>
<publicationStmt>
<date when="2011">2011</date>
<idno type="doi">10.1016/j.ultramic.2011.01.040</idno>
<idno type="RBID">pubmed:21740859</idno>
<idno type="pmid">21740859</idno>
<idno type="wicri:Area/Main/Corpus">001284</idno>
<idno type="wicri:Area/Main/Curation">001284</idno>
<idno type="wicri:Area/Main/Exploration">001092</idno>
</publicationStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The current-dependent beam divergence at a distance of 50 μm from an indium-liquid metal ion source is derived from experimental data obtained by measuring the beam spread with a 3D Plasma diagnostic system at a distance of 10 cm from the needle tip. The observed relationship between emission current and beam divergence in vicinity of the emitting needle is used to design a focusing electrode for a field-emission electric propulsion thruster operating at currents up to 150 μA. Another application involves focused ion beam columns which may choose to forego a beam-limiting aperture, such as LMIS-based rapid machining tools with large beam currents.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="PubMed-not-MEDLINE">
<PMID Version="1">21740859</PMID>
<DateCreated>
<Year>2011</Year>
<Month>08</Month>
<Day>25</Day>
</DateCreated>
<DateCompleted>
<Year>2012</Year>
<Month>01</Month>
<Day>05</Day>
</DateCompleted>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1879-2723</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>111</Volume>
<Issue>8</Issue>
<PubDate>
<Year>2011</Year>
<Month>Jul</Month>
</PubDate>
</JournalIssue>
<Title>Ultramicroscopy</Title>
<ISOAbbreviation>Ultramicroscopy</ISOAbbreviation>
</Journal>
<ArticleTitle>The beam divergence of an indium LMIS at a distance of 50 μm as determined by plasma diagnostic measurements.</ArticleTitle>
<Pagination>
<MedlinePgn>969-72</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/j.ultramic.2011.01.040</ELocationID>
<Abstract>
<AbstractText>The current-dependent beam divergence at a distance of 50 μm from an indium-liquid metal ion source is derived from experimental data obtained by measuring the beam spread with a 3D Plasma diagnostic system at a distance of 10 cm from the needle tip. The observed relationship between emission current and beam divergence in vicinity of the emitting needle is used to design a focusing electrode for a field-emission electric propulsion thruster operating at currents up to 150 μA. Another application involves focused ion beam columns which may choose to forego a beam-limiting aperture, such as LMIS-based rapid machining tools with large beam currents.</AbstractText>
<CopyrightInformation>Copyright © 2011 Elsevier B.V. All rights reserved.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Vasiljevich</LastName>
<ForeName>I</ForeName>
<Initials>I</Initials>
<Affiliation>FOTEC, Wiener Neustadt, Austria. vasiljevich@fotec.at</Affiliation>
</Author>
<Author ValidYN="Y">
<LastName>Tajmar</LastName>
<ForeName>M</ForeName>
<Initials>M</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType>Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2011</Year>
<Month>02</Month>
<Day>03</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>Netherlands</Country>
<MedlineTA>Ultramicroscopy</MedlineTA>
<NlmUniqueID>7513702</NlmUniqueID>
<ISSNLinking>0304-3991</ISSNLinking>
</MedlineJournalInfo>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="received">
<Year>2010</Year>
<Month>11</Month>
<Day>15</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="revised">
<Year>2011</Year>
<Month>1</Month>
<Day>24</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2011</Year>
<Month>1</Month>
<Day>27</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="aheadofprint">
<Year>2011</Year>
<Month>2</Month>
<Day>3</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2011</Year>
<Month>7</Month>
<Day>12</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2011</Year>
<Month>7</Month>
<Day>12</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2011</Year>
<Month>7</Month>
<Day>12</Day>
<Hour>6</Hour>
<Minute>1</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pii">S0304-3991(11)00064-7</ArticleId>
<ArticleId IdType="doi">10.1016/j.ultramic.2011.01.040</ArticleId>
<ArticleId IdType="pubmed">21740859</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=IndiumV2/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001092 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 001092 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=   *** parameter Area/wikiCode missing *** 
   |area=    IndiumV2
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:21740859
   |texte=   The beam divergence of an indium LMIS at a distance of 50 μm as determined by plasma diagnostic measurements.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:21740859" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a IndiumV2 

Wicri

This area was generated with Dilib version V0.5.76.
Data generation: Tue May 20 07:24:43 2014. Site generation: Thu Mar 7 11:12:53 2024