Determination of trace impurities in tin by neutron activation analysis
Identifieur interne : 000B30 ( Main/Exploration ); précédent : 000B29; suivant : 000B31Determination of trace impurities in tin by neutron activation analysis
Auteurs : RBID : ISTEX:10967_1971_Article_BF02514009.pdfAbstract
Two methods are described to determine indium and managenese in high-purity tin. In the first method indium and manganese are separated from the tin and antimony matrix activities on Dowex 1X8 anion exchanger. Tin and antimony are adsorbed in 10M HF while indium and manganese are eluted. In the second method the incident γ-ray intensity due to the tin matrix is reduced by placing a lead absorber between the sample and the detector. The reproducibility and the sensitivity of both methods are of the order of 10 ppb for manganese and of 1 ppb for indium for 1 g samples and a neutron flux of 1011 n·cm−2·sec−1.
DOI: 10.1007/BF02514009
Links toward previous steps (curation, corpus...)
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title>Determination of trace impurities in tin by neutron activation analysis</title>
<author><name>W. Maenhaut</name>
<affiliation wicri:level="1"><mods:affiliation>Institute for Nuclear Sciences, University of Ghent, Ghent, Belgium</mods:affiliation>
<country xml:lang="fr">Belgique</country>
<wicri:regionArea>Institute for Nuclear Sciences, University of Ghent, Ghent</wicri:regionArea>
<wicri:noRegion>Ghent</wicri:noRegion>
</affiliation>
</author>
<author><name>F. Adams</name>
<affiliation wicri:level="1"><mods:affiliation>Institute for Nuclear Sciences, University of Ghent, Ghent, Belgium</mods:affiliation>
<country xml:lang="fr">Belgique</country>
<wicri:regionArea>Institute for Nuclear Sciences, University of Ghent, Ghent</wicri:regionArea>
<wicri:noRegion>Ghent</wicri:noRegion>
</affiliation>
</author>
<author><name>J. Hoste</name>
<affiliation wicri:level="1"><mods:affiliation>Institute for Nuclear Sciences, University of Ghent, Ghent, Belgium</mods:affiliation>
<country xml:lang="fr">Belgique</country>
<wicri:regionArea>Institute for Nuclear Sciences, University of Ghent, Ghent</wicri:regionArea>
<wicri:noRegion>Ghent</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="RBID">ISTEX:10967_1971_Article_BF02514009.pdf</idno>
<date when="1971">1971</date>
<idno type="doi">10.1007/BF02514009</idno>
<idno type="wicri:Area/Main/Corpus">000563</idno>
<idno type="wicri:Area/Main/Curation">000563</idno>
<idno type="wicri:Area/Main/Exploration">000B30</idno>
</publicationStmt>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="eng">Two methods are described to determine indium and managenese in high-purity tin. In the first method indium and manganese are separated from the tin and antimony matrix activities on Dowex 1X8 anion exchanger. Tin and antimony are adsorbed in 10M HF while indium and manganese are eluted. In the second method the incident γ-ray intensity due to the tin matrix is reduced by placing a lead absorber between the sample and the detector. The reproducibility and the sensitivity of both methods are of the order of 10 ppb for manganese and of 1 ppb for indium for 1 g samples and a neutron flux of 1011 n·cm−2·sec−1.</div>
</front>
</TEI>
<mods xsi:schemaLocation="http://www.loc.gov/mods/v3 file:///applis/istex/home/loadistex/home/etc/xsd/mods.xsd" version="3.4" istexId="61a193f441ac82965025829bef47fea93b8e017d"><titleInfo lang="eng"><title>Determination of trace impurities in tin by neutron activation analysis</title>
<subTitle>II. Determination of indium and manganese</subTitle>
</titleInfo>
<name type="personal"><namePart type="given">W.</namePart>
<namePart type="family">Maenhaut</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Institute for Nuclear Sciences, University of Ghent, Ghent, Belgium</affiliation>
</name>
<name type="personal"><namePart type="given">F.</namePart>
<namePart type="family">Adams</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Institute for Nuclear Sciences, University of Ghent, Ghent, Belgium</affiliation>
</name>
<name type="personal"><namePart type="given">J.</namePart>
<namePart type="family">Hoste</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Institute for Nuclear Sciences, University of Ghent, Ghent, Belgium</affiliation>
</name>
<typeOfResource>text</typeOfResource>
<genre>Original Paper</genre>
<originInfo><publisher>Kluwer Academic Publishers, Dordrecht</publisher>
<dateCreated encoding="w3cdtf">1971-04-15</dateCreated>
<dateValid encoding="w3cdtf">2006-09-26</dateValid>
<copyrightDate encoding="w3cdtf">1971</copyrightDate>
</originInfo>
<language><languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription><internetMediaType>text/html</internetMediaType>
</physicalDescription>
<abstract lang="eng">Two methods are described to determine indium and managenese in high-purity tin. In the first method indium and manganese are separated from the tin and antimony matrix activities on Dowex 1X8 anion exchanger. Tin and antimony are adsorbed in 10M HF while indium and manganese are eluted. In the second method the incident γ-ray intensity due to the tin matrix is reduced by placing a lead absorber between the sample and the detector. The reproducibility and the sensitivity of both methods are of the order of 10 ppb for manganese and of 1 ppb for indium for 1 g samples and a neutron flux of 1011 n·cm−2·sec−1.</abstract>
<relatedItem type="series"><titleInfo type="abbreviated"><title>J. Radioanal. Chem.</title>
</titleInfo>
<titleInfo><title>Journal of Radioanalytical Chemistry</title>
<subTitle>International Journal dealing with all aspects of nuclear analytical methods</subTitle>
<partNumber>Year: 1971</partNumber>
<partNumber>Volume: 9</partNumber>
<partNumber>Number: 1</partNumber>
</titleInfo>
<genre>Archive Journal</genre>
<originInfo><dateIssued encoding="w3cdtf">1971-10-01</dateIssued>
<copyrightDate encoding="w3cdtf">1971</copyrightDate>
</originInfo>
<subject usage="primary"><topic>Chemistry</topic>
<topic>Inorganic Chemistry</topic>
<topic>Physical Chemistry</topic>
<topic>Nuclear Chemistry</topic>
<topic>Diagnostic Radiology</topic>
<topic>Nuclear Physics, Heavy Ions, Hadrons</topic>
</subject>
<identifier type="issn">0022-4081</identifier>
<identifier type="issn">Electronic: 1588-2780</identifier>
<identifier type="matrixNumber">10967</identifier>
<identifier type="local">IssueArticleCount: 13</identifier>
<recordInfo><recordOrigin>Akadémiai Kiadó, 1971</recordOrigin>
</recordInfo>
</relatedItem>
<identifier type="doi">10.1007/BF02514009</identifier>
<identifier type="matrixNumber">Art4</identifier>
<identifier type="local">BF02514009</identifier>
<accessCondition type="use and reproduction">MetadataGrant: OpenAccess</accessCondition>
<accessCondition type="use and reproduction">AbstractGrant: OpenAccess</accessCondition>
<accessCondition type="restriction on access">BodyPDFGrant: Restricted</accessCondition>
<accessCondition type="restriction on access">BodyHTMLGrant: Restricted</accessCondition>
<accessCondition type="restriction on access">BibliographyGrant: Restricted</accessCondition>
<accessCondition type="restriction on access">ESMGrant: Restricted</accessCondition>
<part><extent unit="pages"><start>27</start>
<end>38</end>
</extent>
</part>
<recordInfo><recordOrigin>Akadémiai Kiadó, 1971</recordOrigin>
<recordIdentifier>10967_1971_Article_BF02514009.pdf</recordIdentifier>
</recordInfo>
</mods>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=IndiumV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000B30 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000B30 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= *** parameter Area/wikiCode missing *** |area= IndiumV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:10967_1971_Article_BF02514009.pdf |texte= Determination of trace impurities in tin by neutron activation analysis }}
This area was generated with Dilib version V0.5.81. |