113mIn-DTPA, a useful compound for the determination of glomerular filtration rate (GFR)
Identifieur interne : 000893 ( Main/Exploration ); précédent : 000892; suivant : 000894113mIn-DTPA, a useful compound for the determination of glomerular filtration rate (GFR)
Auteurs : RBID : ISTEX:259_1978_Article_BF00256640.pdfAbstract
For measurement of glomerular filtration rate the usefulness of diethyl triamino penta acic (DTPA) labelled with 113mIndium has been explored.The labelling procedure is very simple, since eluate from an 113mIn generator can be used directly for labelling DTPA.The in vitro and in vivo binding of 113mIn to DTPA in competition with serum proteins was studied by gel-filtration. The radioactivity within the 113mIn-DTPA peak represented 100.6, 107.1 and 99.6% of the amount of radioactivity applied to the gel column for the in vivo studies, and 102.0 and 101.4% for the in vitro studies.Furthermore, the clearance of 113mIn-DTPA was compared to the clearance of 125I-iothalamate using the constant infusion technique. The clearance values were found to be nearly equal (r=0.996).It is concluded that 113mIn is almost entirely bound to DTPA after intravenous injection of the 113mIn-DTPA complex, and that the complex is a suitable agent for determination of glomerular filtration rate.
DOI: 10.1007/BF00256640
Links toward previous steps (curation, corpus...)
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title>113mIn-DTPA, a useful compound for the determination of glomerular filtration rate (GFR)</title>
<author><name>R. S. Johansson</name>
<affiliation wicri:level="1"><mods:affiliation>Hormone- and Isotope Laboratory, Aker Hospital, Oslo, Norway</mods:affiliation>
<country xml:lang="fr">Norvège</country>
<wicri:regionArea>Hormone- and Isotope Laboratory, Aker Hospital, Oslo</wicri:regionArea>
<wicri:noRegion>Oslo</wicri:noRegion>
</affiliation>
</author>
<author><name>D. K. Falch</name>
<affiliation wicri:level="1"><mods:affiliation>Hormone- and Isotope Laboratory, Aker Hospital, Oslo, Norway</mods:affiliation>
<country xml:lang="fr">Norvège</country>
<wicri:regionArea>Hormone- and Isotope Laboratory, Aker Hospital, Oslo</wicri:regionArea>
<wicri:noRegion>Oslo</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="RBID">ISTEX:259_1978_Article_BF00256640.pdf</idno>
<date when="1978">1978</date>
<idno type="doi">10.1007/BF00256640</idno>
<idno type="wicri:Area/Main/Corpus">000A09</idno>
<idno type="wicri:Area/Main/Curation">000A09</idno>
<idno type="wicri:Area/Main/Exploration">000893</idno>
</publicationStmt>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="eng">For measurement of glomerular filtration rate the usefulness of diethyl triamino penta acic (DTPA) labelled with 113mIndium has been explored.The labelling procedure is very simple, since eluate from an 113mIn generator can be used directly for labelling DTPA.The in vitro and in vivo binding of 113mIn to DTPA in competition with serum proteins was studied by gel-filtration. The radioactivity within the 113mIn-DTPA peak represented 100.6, 107.1 and 99.6% of the amount of radioactivity applied to the gel column for the in vivo studies, and 102.0 and 101.4% for the in vitro studies.Furthermore, the clearance of 113mIn-DTPA was compared to the clearance of 125I-iothalamate using the constant infusion technique. The clearance values were found to be nearly equal (r=0.996).It is concluded that 113mIn is almost entirely bound to DTPA after intravenous injection of the 113mIn-DTPA complex, and that the complex is a suitable agent for determination of glomerular filtration rate.</div>
</front>
</TEI>
<mods xsi:schemaLocation="http://www.loc.gov/mods/v3 file:///applis/istex/home/loadistex/home/etc/xsd/mods.xsd" version="3.4" istexId="b1627f3e46d1e455b311138d5f978928cc465a40"><titleInfo lang="eng"><title>113mIn-DTPA, a useful compound for the determination of glomerular filtration rate (GFR)</title>
<subTitle>The binding of 113mIn to DTPA and a comparison between GFR estimated with 113mIn-DTPA and 125I-iothalamate</subTitle>
</titleInfo>
<name type="personal"><namePart type="given">R. S.</namePart>
<namePart type="family">Johansson</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Hormone- and Isotope Laboratory, Aker Hospital, Oslo, Norway</affiliation>
</name>
<name type="personal"><namePart type="given">D. K.</namePart>
<namePart type="family">Falch</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Hormone- and Isotope Laboratory, Aker Hospital, Oslo, Norway</affiliation>
</name>
<typeOfResource>text</typeOfResource>
<genre>Original Paper</genre>
<originInfo><publisher>Springer-Verlag, Berlin/Heidelberg</publisher>
<dateCreated encoding="w3cdtf">1977-12-13</dateCreated>
<dateValid encoding="w3cdtf">2004-08-06</dateValid>
<copyrightDate encoding="w3cdtf">1978</copyrightDate>
</originInfo>
<language><languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription><internetMediaType>text/html</internetMediaType>
</physicalDescription>
<abstract lang="eng">For measurement of glomerular filtration rate the usefulness of diethyl triamino penta acic (DTPA) labelled with 113mIndium has been explored.The labelling procedure is very simple, since eluate from an 113mIn generator can be used directly for labelling DTPA.The in vitro and in vivo binding of 113mIn to DTPA in competition with serum proteins was studied by gel-filtration. The radioactivity within the 113mIn-DTPA peak represented 100.6, 107.1 and 99.6% of the amount of radioactivity applied to the gel column for the in vivo studies, and 102.0 and 101.4% for the in vitro studies.Furthermore, the clearance of 113mIn-DTPA was compared to the clearance of 125I-iothalamate using the constant infusion technique. The clearance values were found to be nearly equal (r=0.996).It is concluded that 113mIn is almost entirely bound to DTPA after intravenous injection of the 113mIn-DTPA complex, and that the complex is a suitable agent for determination of glomerular filtration rate.</abstract>
<relatedItem type="series"><titleInfo type="abbreviated"><title>Eur J Nucl Med</title>
</titleInfo>
<titleInfo><title>European Journal of Nuclear Medicine</title>
<partNumber>Year: 1978</partNumber>
<partNumber>Volume: 3</partNumber>
<partNumber>Number: 3</partNumber>
</titleInfo>
<genre>Archive Journal</genre>
<originInfo><dateIssued encoding="w3cdtf">1978-09-01</dateIssued>
<copyrightDate encoding="w3cdtf">1978</copyrightDate>
</originInfo>
<subject usage="primary"><topic>Medicine & Public Health</topic>
<topic>Imaging / Radiology</topic>
<topic>Nuclear Medicine</topic>
</subject>
<identifier type="issn">0340-6997</identifier>
<identifier type="issn">Electronic: 1619-7089</identifier>
<identifier type="matrixNumber">259</identifier>
<identifier type="local">IssueArticleCount: 12</identifier>
<recordInfo><recordOrigin>Springer-Verlag, 1978</recordOrigin>
</recordInfo>
</relatedItem>
<identifier type="doi">10.1007/BF00256640</identifier>
<identifier type="matrixNumber">Art6</identifier>
<identifier type="local">BF00256640</identifier>
<accessCondition type="use and reproduction">MetadataGrant: OpenAccess</accessCondition>
<accessCondition type="use and reproduction">AbstractGrant: OpenAccess</accessCondition>
<accessCondition type="restriction on access">BodyPDFGrant: Restricted</accessCondition>
<accessCondition type="restriction on access">BodyHTMLGrant: Restricted</accessCondition>
<accessCondition type="restriction on access">BibliographyGrant: Restricted</accessCondition>
<accessCondition type="restriction on access">ESMGrant: Restricted</accessCondition>
<part><extent unit="pages"><start>179</start>
<end>181</end>
</extent>
</part>
<recordInfo><recordOrigin>Springer-Verlag, 1978</recordOrigin>
<recordIdentifier>259_1978_Article_BF00256640.pdf</recordIdentifier>
</recordInfo>
</mods>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=IndiumV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000893 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000893 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= *** parameter Area/wikiCode missing *** |area= IndiumV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:259_1978_Article_BF00256640.pdf |texte= 113mIn-DTPA, a useful compound for the determination of glomerular filtration rate (GFR) }}
This area was generated with Dilib version V0.5.81. |