Leucocyte scanning: Preparation and labelling of leucocytes with 111-Indium oxine and its clinical application
Identifieur interne : 000719 ( Main/Exploration ); précédent : 000718; suivant : 000720Leucocyte scanning: Preparation and labelling of leucocytes with 111-Indium oxine and its clinical application
Auteurs : RBID : ISTEX:259_1984_Article_BF00254344.pdfAbstract
A method for the concentration of leucocytes from blood and labelling of the separated cells with 111-Indium oxine is described. This method guaranteed a good preparation. On average there were 64.8% of leucocytes from the blood in the concentrate. The yield of the labelling averaged 93%. Seventy-two patients from various departments were examined to test the clinical application of the labelled leucocytes in the diagnosis of inflammatory diseases. The results obtained led to the formulation of six indications for the appropriate application of leucocyte scanning in everyday clinical routine.
DOI: 10.1007/BF00254344
Links toward previous steps (curation, corpus...)
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title>Leucocyte scanning: Preparation and labelling of leucocytes with 111-Indium oxine and its clinical application</title>
<author><name>Astrid Laue</name>
<affiliation wicri:level="3"><mods:affiliation>Institut für Nuklearmedizin und spezielle Biophysik der Medizinischen Hochschule Hannover, D-3000, Hannover 61, Federal Republic of Germany</mods:affiliation>
<country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Institut für Nuklearmedizin und spezielle Biophysik der Medizinischen Hochschule Hannover, D-3000, Hannover 61</wicri:regionArea>
<placeName><region type="land" nuts="2">Basse-Saxe</region>
<settlement type="city">Hanovre</settlement>
</placeName>
</affiliation>
</author>
<author><name>Ute Heinken</name>
<affiliation wicri:level="3"><mods:affiliation>Institut für Nuklearmedizin und spezielle Biophysik der Medizinischen Hochschule Hannover, D-3000, Hannover 61, Federal Republic of Germany</mods:affiliation>
<country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Institut für Nuklearmedizin und spezielle Biophysik der Medizinischen Hochschule Hannover, D-3000, Hannover 61</wicri:regionArea>
<placeName><region type="land" nuts="2">Basse-Saxe</region>
<settlement type="city">Hanovre</settlement>
</placeName>
</affiliation>
</author>
<author><name>Detlef Schulz-Heinken</name>
<affiliation wicri:level="3"><mods:affiliation>Institut für Nuklearmedizin und spezielle Biophysik der Medizinischen Hochschule Hannover, D-3000, Hannover 61, Federal Republic of Germany</mods:affiliation>
<country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Institut für Nuklearmedizin und spezielle Biophysik der Medizinischen Hochschule Hannover, D-3000, Hannover 61</wicri:regionArea>
<placeName><region type="land" nuts="2">Basse-Saxe</region>
<settlement type="city">Hanovre</settlement>
</placeName>
</affiliation>
</author>
<author><name>Heinz Hundeshagen</name>
<affiliation wicri:level="3"><mods:affiliation>Institut für Nuklearmedizin und spezielle Biophysik der Medizinischen Hochschule Hannover, D-3000, Hannover 61, Federal Republic of Germany</mods:affiliation>
<country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Institut für Nuklearmedizin und spezielle Biophysik der Medizinischen Hochschule Hannover, D-3000, Hannover 61</wicri:regionArea>
<placeName><region type="land" nuts="2">Basse-Saxe</region>
<settlement type="city">Hanovre</settlement>
</placeName>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="RBID">ISTEX:259_1984_Article_BF00254344.pdf</idno>
<date when="1984">1984</date>
<idno type="doi">10.1007/BF00254344</idno>
<idno type="wicri:Area/Main/Corpus">000640</idno>
<idno type="wicri:Area/Main/Curation">000640</idno>
<idno type="wicri:Area/Main/Exploration">000719</idno>
</publicationStmt>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="eng">A method for the concentration of leucocytes from blood and labelling of the separated cells with 111-Indium oxine is described. This method guaranteed a good preparation. On average there were 64.8% of leucocytes from the blood in the concentrate. The yield of the labelling averaged 93%. Seventy-two patients from various departments were examined to test the clinical application of the labelled leucocytes in the diagnosis of inflammatory diseases. The results obtained led to the formulation of six indications for the appropriate application of leucocyte scanning in everyday clinical routine.</div>
</front>
</TEI>
<mods xsi:schemaLocation="http://www.loc.gov/mods/v3 file:///applis/istex/home/loadistex/home/etc/xsd/mods.xsd" version="3.4" istexId="6fa04f648372ec5679b5b394527bff94745ab1ee"><titleInfo lang="eng"><title>Leucocyte scanning: Preparation and labelling of leucocytes with 111-Indium oxine and its clinical application</title>
</titleInfo>
<name type="personal"><namePart type="given">Astrid</namePart>
<namePart type="family">Laue</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Institut für Nuklearmedizin und spezielle Biophysik der Medizinischen Hochschule Hannover, D-3000, Hannover 61, Federal Republic of Germany</affiliation>
</name>
<name type="personal"><namePart type="given">Ute</namePart>
<namePart type="family">Heinken</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Institut für Nuklearmedizin und spezielle Biophysik der Medizinischen Hochschule Hannover, D-3000, Hannover 61, Federal Republic of Germany</affiliation>
</name>
<name type="personal"><namePart type="given">Detlef</namePart>
<namePart type="family">Schulz-Heinken</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Institut für Nuklearmedizin und spezielle Biophysik der Medizinischen Hochschule Hannover, D-3000, Hannover 61, Federal Republic of Germany</affiliation>
</name>
<name type="personal"><namePart type="given">Heinz</namePart>
<namePart type="family">Hundeshagen</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Institut für Nuklearmedizin und spezielle Biophysik der Medizinischen Hochschule Hannover, D-3000, Hannover 61, Federal Republic of Germany</affiliation>
</name>
<typeOfResource>text</typeOfResource>
<genre>Original Paper</genre>
<originInfo><publisher>Springer-Verlag, Berlin/Heidelberg</publisher>
<dateCreated encoding="w3cdtf">1983-06-04</dateCreated>
<dateCaptured encoding="w3cdtf">1983-08-27</dateCaptured>
<dateValid encoding="w3cdtf">2004-08-06</dateValid>
<copyrightDate encoding="w3cdtf">1984</copyrightDate>
</originInfo>
<language><languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription><internetMediaType>text/html</internetMediaType>
</physicalDescription>
<abstract lang="eng">A method for the concentration of leucocytes from blood and labelling of the separated cells with 111-Indium oxine is described. This method guaranteed a good preparation. On average there were 64.8% of leucocytes from the blood in the concentrate. The yield of the labelling averaged 93%. Seventy-two patients from various departments were examined to test the clinical application of the labelled leucocytes in the diagnosis of inflammatory diseases. The results obtained led to the formulation of six indications for the appropriate application of leucocyte scanning in everyday clinical routine.</abstract>
<relatedItem type="series"><titleInfo type="abbreviated"><title>Eur J Nucl Med</title>
</titleInfo>
<titleInfo><title>European Journal of Nuclear Medicine</title>
<partNumber>Year: 1984</partNumber>
<partNumber>Volume: 9</partNumber>
<partNumber>Number: 1</partNumber>
</titleInfo>
<genre>Archive Journal</genre>
<originInfo><dateIssued encoding="w3cdtf">1984-01-01</dateIssued>
<copyrightDate encoding="w3cdtf">1984</copyrightDate>
</originInfo>
<subject usage="primary"><topic>Medicine & Public Health</topic>
<topic>Imaging / Radiology</topic>
<topic>Nuclear Medicine</topic>
</subject>
<identifier type="issn">0340-6997</identifier>
<identifier type="issn">Electronic: 1619-7089</identifier>
<identifier type="matrixNumber">259</identifier>
<identifier type="local">IssueArticleCount: 12</identifier>
<recordInfo><recordOrigin>Springer-Verlag, 1984</recordOrigin>
</recordInfo>
</relatedItem>
<identifier type="doi">10.1007/BF00254344</identifier>
<identifier type="matrixNumber">Art4</identifier>
<identifier type="local">BF00254344</identifier>
<accessCondition type="use and reproduction">MetadataGrant: OpenAccess</accessCondition>
<accessCondition type="use and reproduction">AbstractGrant: OpenAccess</accessCondition>
<accessCondition type="restriction on access">BodyPDFGrant: Restricted</accessCondition>
<accessCondition type="restriction on access">BodyHTMLGrant: Restricted</accessCondition>
<accessCondition type="restriction on access">BibliographyGrant: Restricted</accessCondition>
<accessCondition type="restriction on access">ESMGrant: Restricted</accessCondition>
<part><extent unit="pages"><start>17</start>
<end>22</end>
</extent>
</part>
<recordInfo><recordOrigin>Springer-Verlag, 1984</recordOrigin>
<recordIdentifier>259_1984_Article_BF00254344.pdf</recordIdentifier>
</recordInfo>
</mods>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=IndiumV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000719 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000719 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= *** parameter Area/wikiCode missing *** |area= IndiumV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:259_1984_Article_BF00254344.pdf |texte= Leucocyte scanning: Preparation and labelling of leucocytes with 111-Indium oxine and its clinical application }}
This area was generated with Dilib version V0.5.81. |