Granulocyte-specific monoclonal antibody technetium-99m-BW 250/183 and indium-111 oxine-labelled leucocyte scintigraphy in inflammatory bowel disease
Identifieur interne : 000380 ( Main/Exploration ); précédent : 000379; suivant : 000381Granulocyte-specific monoclonal antibody technetium-99m-BW 250/183 and indium-111 oxine-labelled leucocyte scintigraphy in inflammatory bowel disease
Auteurs : RBID : ISTEX:259_1991_Article_BF00173429.pdfEnglish descriptors
- KwdEn :
Abstract
Thirty-three patients suspected of suffering from inflammatory bowel disease were studied. Autologous leucocytes were labelled with indium 111 oxine and re-injected simultaneously with 0.3–0.5 mg of technetium 99m granulocyte-specific monoclonal antibody BW 250/183. Two scans were obtained, the early scan 3–4 h postinjection (p.i.) and the late scan 18–24 h p.i. Using the endoscopy study as standard, the diagnostic accuracy of both agents was determined. Sensitivity, specificity and accuracy of 111In scans was 88.8%, 100.0% and 93.7% at 4 h and 94.7%, 100.0% and 96.9% at 24 h, respectively. Concerning the results using antibodies, the values were 61.1%, 100.0% and 78.1% at 4 h and 78.9%, 92.8% and 84.8% at 24 h, respectively. Segmental analysis showed concordance in 89.3% and 93.3% of the cases at 4 and 24 h, respectively. Though less sensitive and less accurate than scanning employing indium 111 leucocytes, BW 250/183 granulocyte-specific scintigraphy can be used for inflammatory bowel disease diagnosis and localization.
DOI: 10.1007/BF00173429
Links toward previous steps (curation, corpus...)
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title>Granulocyte-specific monoclonal antibody technetium-99m-BW 250/183 and indium-111 oxine-labelled leucocyte scintigraphy in inflammatory bowel disease</title>
<author><name>I. Segarra</name>
<affiliation wicri:level="1"><mods:affiliation>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</mods:affiliation>
<country xml:lang="fr">Espagne</country>
<wicri:regionArea>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona</wicri:regionArea>
<wicri:noRegion>Barcelona</wicri:noRegion>
</affiliation>
</author>
<author><name>M. Roca</name>
<affiliation wicri:level="1"><mods:affiliation>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</mods:affiliation>
<country xml:lang="fr">Espagne</country>
<wicri:regionArea>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona</wicri:regionArea>
<wicri:noRegion>Barcelona</wicri:noRegion>
</affiliation>
</author>
<author><name>C. Baliellas</name>
<affiliation wicri:level="1"><mods:affiliation>Serveis de Gastroenterologia, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</mods:affiliation>
<country xml:lang="fr">Espagne</country>
<wicri:regionArea>Serveis de Gastroenterologia, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona</wicri:regionArea>
<wicri:noRegion>Barcelona</wicri:noRegion>
</affiliation>
</author>
<author><name>L. Vilar</name>
<affiliation wicri:level="1"><mods:affiliation>Serveis de Gastroenterologia, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</mods:affiliation>
<country xml:lang="fr">Espagne</country>
<wicri:regionArea>Serveis de Gastroenterologia, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona</wicri:regionArea>
<wicri:noRegion>Barcelona</wicri:noRegion>
</affiliation>
</author>
<author><name>Y. Ricart</name>
<affiliation wicri:level="1"><mods:affiliation>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</mods:affiliation>
<country xml:lang="fr">Espagne</country>
<wicri:regionArea>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona</wicri:regionArea>
<wicri:noRegion>Barcelona</wicri:noRegion>
</affiliation>
</author>
<author><name>J. Moral</name>
<affiliation wicri:level="1"><mods:affiliation>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</mods:affiliation>
<country xml:lang="fr">Espagne</country>
<wicri:regionArea>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona</wicri:regionArea>
<wicri:noRegion>Barcelona</wicri:noRegion>
</affiliation>
</author>
<author><name>R. Puchal</name>
<affiliation wicri:level="1"><mods:affiliation>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</mods:affiliation>
<country xml:lang="fr">Espagne</country>
<wicri:regionArea>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona</wicri:regionArea>
<wicri:noRegion>Barcelona</wicri:noRegion>
</affiliation>
</author>
<author><name>J. Martin-Comin</name>
<affiliation wicri:level="1"><mods:affiliation>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</mods:affiliation>
<country xml:lang="fr">Espagne</country>
<wicri:regionArea>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona</wicri:regionArea>
<wicri:noRegion>Barcelona</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="RBID">ISTEX:259_1991_Article_BF00173429.pdf</idno>
<date when="1991">1991</date>
<idno type="doi">10.1007/BF00173429</idno>
<idno type="wicri:Area/Main/Corpus">000440</idno>
<idno type="wicri:Area/Main/Curation">000440</idno>
<idno type="wicri:Area/Main/Exploration">000380</idno>
</publicationStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Granulocyte-specific monoclonal antibody</term>
<term>Inflammatory bowel disease</term>
<term>Leucocyte scintigraphy</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="eng">Thirty-three patients suspected of suffering from inflammatory bowel disease were studied. Autologous leucocytes were labelled with indium 111 oxine and re-injected simultaneously with 0.3–0.5 mg of technetium 99m granulocyte-specific monoclonal antibody BW 250/183. Two scans were obtained, the early scan 3–4 h postinjection (p.i.) and the late scan 18–24 h p.i. Using the endoscopy study as standard, the diagnostic accuracy of both agents was determined. Sensitivity, specificity and accuracy of 111In scans was 88.8%, 100.0% and 93.7% at 4 h and 94.7%, 100.0% and 96.9% at 24 h, respectively. Concerning the results using antibodies, the values were 61.1%, 100.0% and 78.1% at 4 h and 78.9%, 92.8% and 84.8% at 24 h, respectively. Segmental analysis showed concordance in 89.3% and 93.3% of the cases at 4 and 24 h, respectively. Though less sensitive and less accurate than scanning employing indium 111 leucocytes, BW 250/183 granulocyte-specific scintigraphy can be used for inflammatory bowel disease diagnosis and localization.</div>
</front>
</TEI>
<mods xsi:schemaLocation="http://www.loc.gov/mods/v3 file:///applis/istex/home/loadistex/home/etc/xsd/mods.xsd" version="3.4" istexId="4c99b9dca742250c7988ecf4bf55b9eca4252f45"><titleInfo lang="eng"><title>Granulocyte-specific monoclonal antibody technetium-99m-BW 250/183 and indium-111 oxine-labelled leucocyte scintigraphy in inflammatory bowel disease</title>
</titleInfo>
<name type="personal"><namePart type="given">I.</namePart>
<namePart type="family">Segarra</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</affiliation>
</name>
<name type="personal"><namePart type="given">M.</namePart>
<namePart type="family">Roca</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</affiliation>
</name>
<name type="personal"><namePart type="given">C.</namePart>
<namePart type="family">Baliellas</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Serveis de Gastroenterologia, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</affiliation>
</name>
<name type="personal"><namePart type="given">L.</namePart>
<namePart type="family">Vilar</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Serveis de Gastroenterologia, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</affiliation>
</name>
<name type="personal"><namePart type="given">Y.</namePart>
<namePart type="family">Ricart</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</affiliation>
</name>
<name type="personal"><namePart type="given">J.</namePart>
<namePart type="family">Moral</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</affiliation>
</name>
<name type="personal"><namePart type="given">R.</namePart>
<namePart type="family">Puchal</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</affiliation>
</name>
<name type="personal"><namePart type="given">J.</namePart>
<namePart type="family">Martin-Comin</namePart>
<role><roleTerm type="text">author</roleTerm>
</role>
<affiliation>Serveis de Medicina Nuclear, Hospital de Bellvitage, Feixa Llarga s/n, 08907 Hospitalet de LL, Barcelona, Spain</affiliation>
</name>
<typeOfResource>text</typeOfResource>
<genre>Original articles</genre>
<genre>Original Paper</genre>
<originInfo><publisher>Springer-Verlag, Berlin/Heidelberg</publisher>
<dateCreated encoding="w3cdtf">1991-01-21</dateCreated>
<dateValid encoding="w3cdtf">2004-07-03</dateValid>
<copyrightDate encoding="w3cdtf">1991</copyrightDate>
</originInfo>
<language><languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription><internetMediaType>text/html</internetMediaType>
</physicalDescription>
<abstract lang="eng">Thirty-three patients suspected of suffering from inflammatory bowel disease were studied. Autologous leucocytes were labelled with indium 111 oxine and re-injected simultaneously with 0.3–0.5 mg of technetium 99m granulocyte-specific monoclonal antibody BW 250/183. Two scans were obtained, the early scan 3–4 h postinjection (p.i.) and the late scan 18–24 h p.i. Using the endoscopy study as standard, the diagnostic accuracy of both agents was determined. Sensitivity, specificity and accuracy of 111In scans was 88.8%, 100.0% and 93.7% at 4 h and 94.7%, 100.0% and 96.9% at 24 h, respectively. Concerning the results using antibodies, the values were 61.1%, 100.0% and 78.1% at 4 h and 78.9%, 92.8% and 84.8% at 24 h, respectively. Segmental analysis showed concordance in 89.3% and 93.3% of the cases at 4 and 24 h, respectively. Though less sensitive and less accurate than scanning employing indium 111 leucocytes, BW 250/183 granulocyte-specific scintigraphy can be used for inflammatory bowel disease diagnosis and localization.</abstract>
<subject lang="eng"><genre>Key words</genre>
<topic>Inflammatory bowel disease</topic>
<topic>Leucocyte scintigraphy</topic>
<topic>Granulocyte-specific monoclonal antibody</topic>
</subject>
<relatedItem type="series"><titleInfo type="abbreviated"><title>Eur J Nucl Med</title>
</titleInfo>
<titleInfo><title>European Journal of Nuclear Medicine</title>
<partNumber>Year: 1991</partNumber>
<partNumber>Volume: 18</partNumber>
<partNumber>Number: 9</partNumber>
</titleInfo>
<genre>Archive Journal</genre>
<originInfo><dateIssued encoding="w3cdtf">1991-09-01</dateIssued>
<copyrightDate encoding="w3cdtf">1991</copyrightDate>
</originInfo>
<subject usage="primary"><topic>Medicine & Public Health</topic>
<topic>Imaging / Radiology</topic>
<topic>Nuclear Medicine</topic>
</subject>
<identifier type="issn">0340-6997</identifier>
<identifier type="issn">Electronic: 1619-7089</identifier>
<identifier type="matrixNumber">259</identifier>
<identifier type="local">IssueArticleCount: 14</identifier>
<recordInfo><recordOrigin>Springer-Verlag, 1991</recordOrigin>
</recordInfo>
</relatedItem>
<identifier type="doi">10.1007/BF00173429</identifier>
<identifier type="matrixNumber">Art2</identifier>
<identifier type="local">BF00173429</identifier>
<accessCondition type="use and reproduction">MetadataGrant: OpenAccess</accessCondition>
<accessCondition type="use and reproduction">AbstractGrant: OpenAccess</accessCondition>
<accessCondition type="restriction on access">BodyPDFGrant: Restricted</accessCondition>
<accessCondition type="restriction on access">BodyHTMLGrant: Restricted</accessCondition>
<accessCondition type="restriction on access">BibliographyGrant: Restricted</accessCondition>
<accessCondition type="restriction on access">ESMGrant: Restricted</accessCondition>
<part><extent unit="pages"><start>715</start>
<end>719</end>
</extent>
</part>
<recordInfo><recordOrigin>Springer-Verlag, 1991</recordOrigin>
<recordIdentifier>259_1991_Article_BF00173429.pdf</recordIdentifier>
</recordInfo>
</mods>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=IndiumV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000380 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000380 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= *** parameter Area/wikiCode missing *** |area= IndiumV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:259_1991_Article_BF00173429.pdf |texte= Granulocyte-specific monoclonal antibody technetium-99m-BW 250/183 and indium-111 oxine-labelled leucocyte scintigraphy in inflammatory bowel disease }}
This area was generated with Dilib version V0.5.81. |