Serveur d'exploration sur l'Indium

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Analyses without calibration curve for determination of indium in sediment and geochemical samples

Identifieur interne : 000215 ( Main/Exploration ); précédent : 000214; suivant : 000216

Analyses without calibration curve for determination of indium in sediment and geochemical samples

Auteurs : RBID : ISTEX:604_1994_Article_BF01242839.pdf

English descriptors

Abstract

Influences of atomization temperatures on the characteristic mass and the atomic absorption coefficient of indium were studied. The results show that the values of characteristic mass obtained from the wall, using the platform and the V-shaped boat have appeared to be stable to better than 10, 6 and 12% in the range of 1600–2400 °C, respectively. The determination of indium without calibration curve by furnace with the V-shaped boat using palladium and ammonium salt of EDTA as a matrix modifier are described. The proposed method was applied to the determination of indium in standard sediment and geochemical reference samples and satisfactory results were obtained.

DOI: 10.1007/BF01242839

Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title>Analyses without calibration curve for determination of indium in sediment and geochemical samples</title>
<author>
<name>Yansheng Zheng</name>
<affiliation wicri:level="1">
<mods:affiliation>Department of Chemistry, Jilin University, 130023, Changchun, Peoples Republic of China</mods:affiliation>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Department of Chemistry, Jilin University, 130023, Changchun</wicri:regionArea>
<wicri:noRegion>Changchun</wicri:noRegion>
</affiliation>
</author>
<author>
<name>Xingguang Su</name>
<affiliation wicri:level="1">
<mods:affiliation>Department of Chemistry, Jilin University, 130023, Changchun, Peoples Republic of China</mods:affiliation>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Department of Chemistry, Jilin University, 130023, Changchun</wicri:regionArea>
<wicri:noRegion>Changchun</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="RBID">ISTEX:604_1994_Article_BF01242839.pdf</idno>
<date when="1994">1994</date>
<idno type="doi">10.1007/BF01242839</idno>
<idno type="wicri:Area/Main/Corpus">000684</idno>
<idno type="wicri:Area/Main/Curation">000684</idno>
<idno type="wicri:Area/Main/Exploration">000215</idno>
</publicationStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Analyses without calibration curve</term>
<term>Characteristic mass</term>
<term>Furnace with V-shaped boat</term>
<term>Indium determination</term>
<term>Matrix modifier</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="eng">Influences of atomization temperatures on the characteristic mass and the atomic absorption coefficient of indium were studied. The results show that the values of characteristic mass obtained from the wall, using the platform and the V-shaped boat have appeared to be stable to better than 10, 6 and 12% in the range of 1600–2400 °C, respectively. The determination of indium without calibration curve by furnace with the V-shaped boat using palladium and ammonium salt of EDTA as a matrix modifier are described. The proposed method was applied to the determination of indium in standard sediment and geochemical reference samples and satisfactory results were obtained.</div>
</front>
</TEI>
<mods xsi:schemaLocation="http://www.loc.gov/mods/v3 file:///applis/istex/home/loadistex/home/etc/xsd/mods.xsd" version="3.4" istexId="75a79b65e8e2c34f391fdcb86e05cbe715a1a82f">
<titleInfo lang="eng">
<title>Analyses without calibration curve for determination of indium in sediment and geochemical samples</title>
</titleInfo>
<name type="personal">
<namePart type="given">Yansheng</namePart>
<namePart type="family">Zheng</namePart>
<role>
<roleTerm type="text">author</roleTerm>
</role>
<affiliation>Department of Chemistry, Jilin University, 130023, Changchun, Peoples Republic of China</affiliation>
</name>
<name type="personal">
<namePart type="given">Xingguang</namePart>
<namePart type="family">Su</namePart>
<role>
<roleTerm type="text">author</roleTerm>
</role>
<affiliation>Department of Chemistry, Jilin University, 130023, Changchun, Peoples Republic of China</affiliation>
</name>
<typeOfResource>text</typeOfResource>
<genre>Original Paper</genre>
<genre>Original Paper</genre>
<originInfo>
<publisher>Springer-Verlag, Vienna</publisher>
<dateCreated encoding="w3cdtf">1992-11-13</dateCreated>
<dateValid encoding="w3cdtf">2005-02-15</dateValid>
<copyrightDate encoding="w3cdtf">1994</copyrightDate>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<internetMediaType>text/html</internetMediaType>
</physicalDescription>
<abstract lang="eng">Influences of atomization temperatures on the characteristic mass and the atomic absorption coefficient of indium were studied. The results show that the values of characteristic mass obtained from the wall, using the platform and the V-shaped boat have appeared to be stable to better than 10, 6 and 12% in the range of 1600–2400 °C, respectively. The determination of indium without calibration curve by furnace with the V-shaped boat using palladium and ammonium salt of EDTA as a matrix modifier are described. The proposed method was applied to the determination of indium in standard sediment and geochemical reference samples and satisfactory results were obtained.</abstract>
<subject lang="eng">
<genre>Key words</genre>
<topic>indium determination</topic>
<topic>analyses without calibration curve</topic>
<topic>characteristic mass</topic>
<topic>matrix modifier</topic>
<topic>furnace with V-shaped boat</topic>
</subject>
<relatedItem type="series">
<titleInfo type="abbreviated">
<title>Mikrochim Acta</title>
</titleInfo>
<titleInfo>
<title>Microchimica Acta</title>
<subTitle>Micro and Trance Analysis</subTitle>
<partNumber>Year: 1994</partNumber>
<partNumber>Volume: 112</partNumber>
<partNumber>Number: 5-6</partNumber>
</titleInfo>
<genre>Archive Journal</genre>
<originInfo>
<dateIssued encoding="w3cdtf">1994-09-01</dateIssued>
<copyrightDate encoding="w3cdtf">1994</copyrightDate>
</originInfo>
<subject usage="primary">
<topic>Chemistry</topic>
<topic>Analytical Chemistry</topic>
<topic>Inorganic Chemistry</topic>
<topic>Physical Chemistry</topic>
<topic>Characterization and Evaluation Materials</topic>
<topic>Monitoring/Environmental Analysis/Environmental Ecotoxicology</topic>
</subject>
<identifier type="issn">0026-3672</identifier>
<identifier type="issn">Electronic: 1436-5073</identifier>
<identifier type="matrixNumber">604</identifier>
<identifier type="local">IssueArticleCount: 10</identifier>
<recordInfo>
<recordOrigin>Springer-Verlag, 1994</recordOrigin>
</recordInfo>
</relatedItem>
<identifier type="doi">10.1007/BF01242839</identifier>
<identifier type="matrixNumber">Art7</identifier>
<identifier type="local">BF01242839</identifier>
<accessCondition type="use and reproduction">MetadataGrant: OpenAccess</accessCondition>
<accessCondition type="use and reproduction">AbstractGrant: OpenAccess</accessCondition>
<accessCondition type="restriction on access">BodyPDFGrant: Restricted</accessCondition>
<accessCondition type="restriction on access">BodyHTMLGrant: Restricted</accessCondition>
<accessCondition type="restriction on access">BibliographyGrant: Restricted</accessCondition>
<accessCondition type="restriction on access">ESMGrant: Restricted</accessCondition>
<part>
<extent unit="pages">
<start>237</start>
<end>243</end>
</extent>
</part>
<recordInfo>
<recordOrigin>Springer-Verlag, 1994</recordOrigin>
<recordIdentifier>604_1994_Article_BF01242839.pdf</recordIdentifier>
</recordInfo>
</mods>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=IndiumV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000215 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000215 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=   *** parameter Area/wikiCode missing *** 
   |area=    IndiumV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:604_1994_Article_BF01242839.pdf
   |texte=   Analyses without calibration curve for determination of indium in sediment and geochemical samples
}}

Wicri

This area was generated with Dilib version V0.5.81.
Data generation: Mon Aug 25 10:35:12 2014. Site generation: Thu Mar 7 10:08:40 2024