Serveur d'exploration sur le cobalt au Maghreb

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

High-performance liquid chromatography and detection of polyethers and their mono(carboxy)alkyl and -arylalkyl substituted derivatives

Identifieur interne : 000F95 ( Main/Exploration ); précédent : 000F94; suivant : 000F96

High-performance liquid chromatography and detection of polyethers and their mono(carboxy)alkyl and -arylalkyl substituted derivatives

Auteurs : Klaus Rissler [Suisse]

Source :

RBID : ISTEX:95429213735C0E09B797CAF1FEF870A8A0F7083F

Abstract

This review deals with high-performance liquid chromatographic (HPLC) separation techniques and detection methods for a wide variety of polyether derivatives, including alkyl-, arylalkyl-, carboxyalkyl-substituted polyethylene glycols mainly applied as non-ionic surfactants (NIS), and native (underivatized) polyethylene glycols (PEGs), polypropylene glycols (PPGs) and polybutylene glycols (PBGs) widely used in either industrial or pharmaceutical applications. Normal-phase (NP) and reversed-phase (RP) systems have been considered for NIS, the NP technique being the most suitable for separation according to the number of ethoxylate units, whereas separation according to the hydrophobic alkyl chain is favored on RP stationary phases. At variance with NIS mainly RP-HPLC is applied for native (underivatized) polyethers of the PEG, PPG and PBG type. Ion-exchange chromatography (IEC) is still a minor technique for the separation of PEG derivatives, which exploits the capability of the 1,2-dioxoethylene moiety to form complexes with potassium ions. Liquid chromatography under critical conditions (LCCC) is the method of choice for separation of polyethers according to their chemical composition and is preferably applicable to copolymers built up from differrent components. A multitude of detection principles substantially differing in either selectivity or sensitivity has been successfully used for signal monitoring, with detection by measurement of refractive indexes (RI), UV absorption, fluorescence and responses from evaporative light scattering of “solid” droplets being the most prominent. Nevertheless, UV detection still dominates because of the existence of the phenyl chromophor in many NIS and the ease of derivatization of polyethers lacking an inherent aromatic moiety with a large variety of chromophoric agents. Additionally, well-established methods are available for low wavelength UV detection below 200 nm even for the native polyethers.

Url:
DOI: 10.1016/0021-9673(96)00168-9


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title>High-performance liquid chromatography and detection of polyethers and their mono(carboxy)alkyl and -arylalkyl substituted derivatives</title>
<author>
<name sortKey="Rissler, Klaus" sort="Rissler, Klaus" uniqKey="Rissler K" first="Klaus" last="Rissler">Klaus Rissler</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:95429213735C0E09B797CAF1FEF870A8A0F7083F</idno>
<date when="1996" year="1996">1996</date>
<idno type="doi">10.1016/0021-9673(96)00168-9</idno>
<idno type="url">https://api.istex.fr/document/95429213735C0E09B797CAF1FEF870A8A0F7083F/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">001A29</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">001A29</idno>
<idno type="wicri:Area/Istex/Curation">001413</idno>
<idno type="wicri:Area/Istex/Checkpoint">000836</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">000836</idno>
<idno type="wicri:doubleKey">0021-9673:1996:Rissler K:high:performance:liquid</idno>
<idno type="wicri:Area/Main/Merge">001034</idno>
<idno type="wicri:Area/Main/Curation">000F95</idno>
<idno type="wicri:Area/Main/Exploration">000F95</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a">High-performance liquid chromatography and detection of polyethers and their mono(carboxy)alkyl and -arylalkyl substituted derivatives</title>
<author>
<name sortKey="Rissler, Klaus" sort="Rissler, Klaus" uniqKey="Rissler K" first="Klaus" last="Rissler">Klaus Rissler</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Suisse</country>
<wicri:regionArea>Polymers Division, K-401.2.08, Ciba-Geigy Ltd., CH-4002 Basle</wicri:regionArea>
<wicri:noRegion>CH-4002 Basle</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Journal of Chromatography A</title>
<title level="j" type="abbrev">CHROMA</title>
<idno type="ISSN">0021-9673</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1996">1996</date>
<biblScope unit="volume">742</biblScope>
<biblScope unit="issue">1–2</biblScope>
<biblScope unit="page" from="1">1</biblScope>
<biblScope unit="page" to="54">54</biblScope>
</imprint>
<idno type="ISSN">0021-9673</idno>
</series>
<idno type="istex">95429213735C0E09B797CAF1FEF870A8A0F7083F</idno>
<idno type="DOI">10.1016/0021-9673(96)00168-9</idno>
<idno type="PII">0021-9673(96)00168-9</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0021-9673</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">This review deals with high-performance liquid chromatographic (HPLC) separation techniques and detection methods for a wide variety of polyether derivatives, including alkyl-, arylalkyl-, carboxyalkyl-substituted polyethylene glycols mainly applied as non-ionic surfactants (NIS), and native (underivatized) polyethylene glycols (PEGs), polypropylene glycols (PPGs) and polybutylene glycols (PBGs) widely used in either industrial or pharmaceutical applications. Normal-phase (NP) and reversed-phase (RP) systems have been considered for NIS, the NP technique being the most suitable for separation according to the number of ethoxylate units, whereas separation according to the hydrophobic alkyl chain is favored on RP stationary phases. At variance with NIS mainly RP-HPLC is applied for native (underivatized) polyethers of the PEG, PPG and PBG type. Ion-exchange chromatography (IEC) is still a minor technique for the separation of PEG derivatives, which exploits the capability of the 1,2-dioxoethylene moiety to form complexes with potassium ions. Liquid chromatography under critical conditions (LCCC) is the method of choice for separation of polyethers according to their chemical composition and is preferably applicable to copolymers built up from differrent components. A multitude of detection principles substantially differing in either selectivity or sensitivity has been successfully used for signal monitoring, with detection by measurement of refractive indexes (RI), UV absorption, fluorescence and responses from evaporative light scattering of “solid” droplets being the most prominent. Nevertheless, UV detection still dominates because of the existence of the phenyl chromophor in many NIS and the ease of derivatization of polyethers lacking an inherent aromatic moiety with a large variety of chromophoric agents. Additionally, well-established methods are available for low wavelength UV detection below 200 nm even for the native polyethers.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Suisse</li>
</country>
</list>
<tree>
<country name="Suisse">
<noRegion>
<name sortKey="Rissler, Klaus" sort="Rissler, Klaus" uniqKey="Rissler K" first="Klaus" last="Rissler">Klaus Rissler</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Terre/explor/CobaltMaghrebV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000F95 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000F95 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Terre
   |area=    CobaltMaghrebV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:95429213735C0E09B797CAF1FEF870A8A0F7083F
   |texte=   High-performance liquid chromatography and detection of polyethers and their mono(carboxy)alkyl and -arylalkyl substituted derivatives
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Tue Nov 14 12:56:51 2017. Site generation: Mon Feb 12 07:59:49 2024