Serveur d'exploration sur le cobalt au Maghreb

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Intensity modulated proton therapy treatment planning using single-field optimization: The impact of monitor unit constraints on plan quality

Identifieur interne : 000567 ( Main/Exploration ); précédent : 000566; suivant : 000568

Intensity modulated proton therapy treatment planning using single-field optimization: The impact of monitor unit constraints on plan quality

Auteurs : X. R. Zhu ; N. Sahoo ; X. Zhang ; D. Robertson ; H. Li

Source :

RBID : PMC:2837732

Abstract

Purpose: To investigate the effect of monitor unit (MU) constraints on the dose distribution created by intensity modulated proton therapy (IMPT) treatment planning using single-field optimization (SFO).

Methods: Ninety-four energies between 72.5 and 221.8 MeV are available for scanning beam IMPT delivery at our institution. The minimum and maximum MUs for delivering each pencil beam (spot) are 0.005 and 0.04, respectively. These MU constraints are not considered during optimization by the treatment planning system; spots are converted to deliverable MUs during postprocessing. Treatment plans for delivering uniform doses to rectangular volumes with and without MU constraints were generated for different target doses, spot spacings, spread-out Bragg peak (SOBP) widths, and ranges in a homogeneous phantom. Four prostate cancer patients were planned with and without MU constraints using different spot spacings. Rounding errors were analyzed using an in-house software tool.

Results: From the phantom study, the authors have found that both the number of spots that have rounding errors and the magnitude of the distortion of the dose distribution from the ideally optimized distribution increases as the field dose, spot spacing, and range decrease and as the SOBP width increases. From our study of patient plans, it is clear that as the spot spacing decreases the rounding error increases, and the dose coverage of the target volume becomes unacceptable for very small spot spacings.

Conclusions: Constraints on deliverable MU for each spot could create a significant distortion from the ideally optimized dose distributions for IMPT fields using SFO. To eliminate this problem, the treatment planning system should incorporate the MU constraints in the optimization process and the delivery system should reliably delivery smaller minimum MUs.


Url:
DOI: 10.1118/1.3314073
PubMed: 20384258
PubMed Central: 2837732


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Intensity modulated proton therapy treatment planning using single-field optimization: The impact of monitor unit constraints on plan quality</title>
<author>
<name sortKey="Zhu, X R" sort="Zhu, X R" uniqKey="Zhu X" first="X. R." last="Zhu">X. R. Zhu</name>
</author>
<author>
<name sortKey="Sahoo, N" sort="Sahoo, N" uniqKey="Sahoo N" first="N." last="Sahoo">N. Sahoo</name>
</author>
<author>
<name sortKey="Zhang, X" sort="Zhang, X" uniqKey="Zhang X" first="X." last="Zhang">X. Zhang</name>
</author>
<author>
<name sortKey="Robertson, D" sort="Robertson, D" uniqKey="Robertson D" first="D." last="Robertson">D. Robertson</name>
</author>
<author>
<name sortKey="Li, H" sort="Li, H" uniqKey="Li H" first="H." last="Li">H. Li</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">20384258</idno>
<idno type="pmc">2837732</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2837732</idno>
<idno type="RBID">PMC:2837732</idno>
<idno type="doi">10.1118/1.3314073</idno>
<date when="2010">2010</date>
<idno type="wicri:Area/Pmc/Corpus">000073</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000073</idno>
<idno type="wicri:Area/Pmc/Curation">000073</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Curation">000073</idno>
<idno type="wicri:Area/Pmc/Checkpoint">000306</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Checkpoint">000306</idno>
<idno type="wicri:Area/Ncbi/Merge">000130</idno>
<idno type="wicri:Area/Ncbi/Curation">000130</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000130</idno>
<idno type="wicri:doubleKey">0094-2405:2010:Zhu X:intensity:modulated:proton</idno>
<idno type="wicri:Area/Main/Merge">000570</idno>
<idno type="wicri:Area/Main/Curation">000567</idno>
<idno type="wicri:Area/Main/Exploration">000567</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Intensity modulated proton therapy treatment planning using single-field optimization: The impact of monitor unit constraints on plan quality</title>
<author>
<name sortKey="Zhu, X R" sort="Zhu, X R" uniqKey="Zhu X" first="X. R." last="Zhu">X. R. Zhu</name>
</author>
<author>
<name sortKey="Sahoo, N" sort="Sahoo, N" uniqKey="Sahoo N" first="N." last="Sahoo">N. Sahoo</name>
</author>
<author>
<name sortKey="Zhang, X" sort="Zhang, X" uniqKey="Zhang X" first="X." last="Zhang">X. Zhang</name>
</author>
<author>
<name sortKey="Robertson, D" sort="Robertson, D" uniqKey="Robertson D" first="D." last="Robertson">D. Robertson</name>
</author>
<author>
<name sortKey="Li, H" sort="Li, H" uniqKey="Li H" first="H." last="Li">H. Li</name>
</author>
</analytic>
<series>
<title level="j">Medical Physics</title>
<idno type="ISSN">0094-2405</idno>
<idno type="eISSN">0094-2405</idno>
<imprint>
<date when="2010">2010</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>
<bold>Purpose:</bold>
To investigate the effect of monitor unit (MU) constraints on the dose distribution created by intensity modulated proton therapy (IMPT) treatment planning using single-field optimization (SFO).</p>
<p>
<bold>Methods:</bold>
Ninety-four energies between 72.5 and 221.8 MeV are available for scanning beam IMPT delivery at our institution. The minimum and maximum MUs for delivering each pencil beam (spot) are 0.005 and 0.04, respectively. These MU constraints are not considered during optimization by the treatment planning system; spots are converted to deliverable MUs during postprocessing. Treatment plans for delivering uniform doses to rectangular volumes with and without MU constraints were generated for different target doses, spot spacings, spread-out Bragg peak (SOBP) widths, and ranges in a homogeneous phantom. Four prostate cancer patients were planned with and without MU constraints using different spot spacings. Rounding errors were analyzed using an in-house software tool.</p>
<p>
<bold>Results:</bold>
From the phantom study, the authors have found that both the number of spots that have rounding errors and the magnitude of the distortion of the dose distribution from the ideally optimized distribution increases as the field dose, spot spacing, and range decrease and as the SOBP width increases. From our study of patient plans, it is clear that as the spot spacing decreases the rounding error increases, and the dose coverage of the target volume becomes unacceptable for very small spot spacings.</p>
<p>
<bold>Conclusions:</bold>
Constraints on deliverable MU for each spot could create a significant distortion from the ideally optimized dose distributions for IMPT fields using SFO. To eliminate this problem, the treatment planning system should incorporate the MU constraints in the optimization process and the delivery system should reliably delivery smaller minimum MUs.</p>
</div>
</front>
</TEI>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Li, H" sort="Li, H" uniqKey="Li H" first="H." last="Li">H. Li</name>
<name sortKey="Robertson, D" sort="Robertson, D" uniqKey="Robertson D" first="D." last="Robertson">D. Robertson</name>
<name sortKey="Sahoo, N" sort="Sahoo, N" uniqKey="Sahoo N" first="N." last="Sahoo">N. Sahoo</name>
<name sortKey="Zhang, X" sort="Zhang, X" uniqKey="Zhang X" first="X." last="Zhang">X. Zhang</name>
<name sortKey="Zhu, X R" sort="Zhu, X R" uniqKey="Zhu X" first="X. R." last="Zhu">X. R. Zhu</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Terre/explor/CobaltMaghrebV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000567 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000567 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Terre
   |area=    CobaltMaghrebV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     PMC:2837732
   |texte=   Intensity modulated proton therapy treatment planning using single-field optimization: The impact of monitor unit constraints on plan quality
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:20384258" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a CobaltMaghrebV1 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Tue Nov 14 12:56:51 2017. Site generation: Mon Feb 12 07:59:49 2024