Auteurs : Olivier Zaouak [France] ; Laurent Authier [France] ; Cyril Cugnet [France] ; Eric Normandin [France] ; Daniel Champier [France] ; Marc Rivaletto [France] ; Martine Potin‐Gautier [France]Source :
- Electroanalysis [ 1040-0397 ] ; 2010-06.
Descripteurs français
- Wicri :
- topic : Automatisation, Cadmium.
English descriptors
Abstract
A full‐automated electroanalytical device is presented here. It is composed of an electrochemically adapted automation module and a competitive screen‐printed sensor modified ex situ by a very low quantity of mercury. The contribution of this automated apparatus to analyses is described in detail. Coupled with an UV‐photolysis unit, it has permitted the rapid detection of both total and electrochemically accessible cadmium in solutions containing 10 mg L−1 of humic substances without addition of reagents. Semicontinuous monitoring of tap water doped with 5.3 μg L−1 of cadmium, in presence of traces of lead and copper, has been successfully achieved for 7 days.
Url:
DOI: 10.1002/elan.200900475
Affiliations:
Links toward previous steps (curation, corpus...)
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Electroanalytical Device for Cadmium Speciation in Waters. Part 2: Automated System Development and Cadmium Semicontinuous Monitoring</title>
<author><name sortKey="Zaouak, Olivier" sort="Zaouak, Olivier" uniqKey="Zaouak O" first="Olivier" last="Zaouak">Olivier Zaouak</name>
</author>
<author><name sortKey="Authier, Laurent" sort="Authier, Laurent" uniqKey="Authier L" first="Laurent" last="Authier">Laurent Authier</name>
</author>
<author><name sortKey="Cugnet, Cyril" sort="Cugnet, Cyril" uniqKey="Cugnet C" first="Cyril" last="Cugnet">Cyril Cugnet</name>
</author>
<author><name sortKey="Normandin, Eric" sort="Normandin, Eric" uniqKey="Normandin E" first="Eric" last="Normandin">Eric Normandin</name>
</author>
<author><name sortKey="Champier, Daniel" sort="Champier, Daniel" uniqKey="Champier D" first="Daniel" last="Champier">Daniel Champier</name>
</author>
<author><name sortKey="Rivaletto, Marc" sort="Rivaletto, Marc" uniqKey="Rivaletto M" first="Marc" last="Rivaletto">Marc Rivaletto</name>
</author>
<author><name sortKey="Potin Autier, Martine" sort="Potin Autier, Martine" uniqKey="Potin Autier M" first="Martine" last="Potin‐Gautier">Martine Potin‐Gautier</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:D49430C9AD118A9390CC16EA97D89A882D829ACA</idno>
<date when="2010">2010</date>
<idno type="doi">10.1002/elan.200900475</idno>
<idno type="url">https://api.istex.fr/document/D49430C9AD118A9390CC16EA97D89A882D829ACA/fulltext/pdf</idno>
<idno type="wicri:Area/Main/Corpus">000281</idno>
<idno type="wicri:Area/Main/Curation">000281</idno>
<idno type="wicri:Area/Main/Exploration">000050</idno>
<idno type="wicri:explorRef" wicri:stream="Main" wicri:step="Exploration">000050</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main" xml:lang="en">Electroanalytical Device for Cadmium Speciation in Waters. Part 2: Automated System Development and Cadmium Semicontinuous Monitoring</title>
<author><name sortKey="Zaouak, Olivier" sort="Zaouak, Olivier" uniqKey="Zaouak O" first="Olivier" last="Zaouak">Olivier Zaouak</name>
<affiliation wicri:level="3"><country xml:lang="fr">France</country>
<wicri:regionArea>Université de Pau et des Pays de l'Adour / CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9</wicri:regionArea>
<placeName><region type="region" nuts="2">Nouvelle-Aquitaine</region>
<region type="old region" nuts="2">Aquitaine</region>
<settlement type="city">Cedex 9</settlement>
</placeName>
</affiliation>
</author>
<author><name sortKey="Authier, Laurent" sort="Authier, Laurent" uniqKey="Authier L" first="Laurent" last="Authier">Laurent Authier</name>
<affiliation wicri:level="1"><country wicri:rule="url">France</country>
</affiliation>
<affiliation wicri:level="3"><country xml:lang="fr">France</country>
<wicri:regionArea>Université de Pau et des Pays de l'Adour / CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9</wicri:regionArea>
<placeName><region type="region" nuts="2">Nouvelle-Aquitaine</region>
<region type="old region" nuts="2">Aquitaine</region>
<settlement type="city">Cedex 9</settlement>
</placeName>
</affiliation>
</author>
<author><name sortKey="Cugnet, Cyril" sort="Cugnet, Cyril" uniqKey="Cugnet C" first="Cyril" last="Cugnet">Cyril Cugnet</name>
<affiliation wicri:level="3"><country xml:lang="fr">France</country>
<wicri:regionArea>Université de Pau et des Pays de l'Adour / CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9</wicri:regionArea>
<placeName><region type="region" nuts="2">Nouvelle-Aquitaine</region>
<region type="old region" nuts="2">Aquitaine</region>
<settlement type="city">Cedex 9</settlement>
</placeName>
</affiliation>
</author>
<author><name sortKey="Normandin, Eric" sort="Normandin, Eric" uniqKey="Normandin E" first="Eric" last="Normandin">Eric Normandin</name>
<affiliation wicri:level="3"><country xml:lang="fr">France</country>
<wicri:regionArea>Université de Pau et des Pays de l'Adour, Innov'Adour, 2 avenue Angot, 64053 PAU Cedex 9</wicri:regionArea>
<placeName><region type="region" nuts="2">Nouvelle-Aquitaine</region>
<region type="old region" nuts="2">Aquitaine</region>
<settlement type="city">Pau</settlement>
</placeName>
</affiliation>
</author>
<author><name sortKey="Champier, Daniel" sort="Champier, Daniel" uniqKey="Champier D" first="Daniel" last="Champier">Daniel Champier</name>
<affiliation wicri:level="3"><country xml:lang="fr">France</country>
<wicri:regionArea>Université de Pau et des Pays de l'Adour, Laboratoire de Génie Electrique/EA 3001, 2 avenue Angot, 64053 PAU Cedex 9</wicri:regionArea>
<placeName><region type="region" nuts="2">Nouvelle-Aquitaine</region>
<region type="old region" nuts="2">Aquitaine</region>
<settlement type="city">Cedex 9</settlement>
</placeName>
</affiliation>
</author>
<author><name sortKey="Rivaletto, Marc" sort="Rivaletto, Marc" uniqKey="Rivaletto M" first="Marc" last="Rivaletto">Marc Rivaletto</name>
<affiliation wicri:level="3"><country xml:lang="fr">France</country>
<wicri:regionArea>Université de Pau et des Pays de l'Adour, Laboratoire de Génie Electrique/EA 3001, 2 avenue Angot, 64053 PAU Cedex 9</wicri:regionArea>
<placeName><region type="region" nuts="2">Nouvelle-Aquitaine</region>
<region type="old region" nuts="2">Aquitaine</region>
<settlement type="city">Cedex 9</settlement>
</placeName>
</affiliation>
</author>
<author><name sortKey="Potin Autier, Martine" sort="Potin Autier, Martine" uniqKey="Potin Autier M" first="Martine" last="Potin‐Gautier">Martine Potin‐Gautier</name>
<affiliation wicri:level="3"><country xml:lang="fr">France</country>
<wicri:regionArea>Université de Pau et des Pays de l'Adour / CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9</wicri:regionArea>
<placeName><region type="region" nuts="2">Nouvelle-Aquitaine</region>
<region type="old region" nuts="2">Aquitaine</region>
<settlement type="city">Cedex 9</settlement>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">Electroanalysis</title>
<title level="j" type="sub">An International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis</title>
<title level="j" type="abbrev">Electroanalysis</title>
<idno type="ISSN">1040-0397</idno>
<imprint><publisher>WILEY‐VCH Verlag</publisher>
<pubPlace>Weinheim</pubPlace>
<date type="published" when="2010-06">2010-06</date>
<biblScope unit="vol">22</biblScope>
<biblScope unit="issue">11</biblScope>
<biblScope unit="page" from="1159">1159</biblScope>
<biblScope unit="page" to="1165">1165</biblScope>
</imprint>
<idno type="ISSN">1040-0397</idno>
</series>
<idno type="istex">D49430C9AD118A9390CC16EA97D89A882D829ACA</idno>
<idno type="DOI">10.1002/elan.200900475</idno>
<idno type="ArticleID">ELAN200900475</idno>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">1040-0397</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Automation</term>
<term>Cadmium</term>
<term>Heavy metals</term>
<term>Semicontinuous monitoring</term>
<term>Stripping voltammetry</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr"><term>Automatisation</term>
<term>Cadmium</term>
</keywords>
</textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">A full‐automated electroanalytical device is presented here. It is composed of an electrochemically adapted automation module and a competitive screen‐printed sensor modified ex situ by a very low quantity of mercury. The contribution of this automated apparatus to analyses is described in detail. Coupled with an UV‐photolysis unit, it has permitted the rapid detection of both total and electrochemically accessible cadmium in solutions containing 10 mg L−1 of humic substances without addition of reagents. Semicontinuous monitoring of tap water doped with 5.3 μg L−1 of cadmium, in presence of traces of lead and copper, has been successfully achieved for 7 days.</div>
</front>
</TEI>
<affiliations><list><country><li>France</li>
</country>
<region><li>Aquitaine</li>
<li>Nouvelle-Aquitaine</li>
</region>
<settlement><li>Cedex 9</li>
<li>Pau</li>
</settlement>
</list>
<tree><country name="France"><region name="Nouvelle-Aquitaine"><name sortKey="Zaouak, Olivier" sort="Zaouak, Olivier" uniqKey="Zaouak O" first="Olivier" last="Zaouak">Olivier Zaouak</name>
</region>
<name sortKey="Authier, Laurent" sort="Authier, Laurent" uniqKey="Authier L" first="Laurent" last="Authier">Laurent Authier</name>
<name sortKey="Authier, Laurent" sort="Authier, Laurent" uniqKey="Authier L" first="Laurent" last="Authier">Laurent Authier</name>
<name sortKey="Champier, Daniel" sort="Champier, Daniel" uniqKey="Champier D" first="Daniel" last="Champier">Daniel Champier</name>
<name sortKey="Cugnet, Cyril" sort="Cugnet, Cyril" uniqKey="Cugnet C" first="Cyril" last="Cugnet">Cyril Cugnet</name>
<name sortKey="Normandin, Eric" sort="Normandin, Eric" uniqKey="Normandin E" first="Eric" last="Normandin">Eric Normandin</name>
<name sortKey="Potin Autier, Martine" sort="Potin Autier, Martine" uniqKey="Potin Autier M" first="Martine" last="Potin‐Gautier">Martine Potin‐Gautier</name>
<name sortKey="Rivaletto, Marc" sort="Rivaletto, Marc" uniqKey="Rivaletto M" first="Marc" last="Rivaletto">Marc Rivaletto</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Terre/explor/CadmiumV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000050 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000050 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Terre |area= CadmiumV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:D49430C9AD118A9390CC16EA97D89A882D829ACA |texte= Electroanalytical Device for Cadmium Speciation in Waters. Part 2: Automated System Development and Cadmium Semicontinuous Monitoring }}
This area was generated with Dilib version V0.6.38. |