Electroanalytical Device for Cadmium Speciation in Waters. Part 1: Development and Characterization of a Reliable Screen‐Printed Sensor

Identifieur interne : 000191 ( Main/Corpus ); précédent : 000190; suivant : 000192

Electroanalytical Device for Cadmium Speciation in Waters. Part 1: Development and Characterization of a Reliable Screen‐Printed Sensor

Auteurs : Olivier Zaouak ; Laurent Authier ; Cyril Cugnet ; Alain Castetbon ; Martine Potin‐Gautier

Source :

RBID : ISTEX:D8CF94BDAD41C3EB438C621537C2556213347DD9

English descriptors

Abstract

A reliable screen‐printed sensor for cadmium speciation analysis is presented here. Its development has been focused on the achievement of a reproducible and repeatable sensor. The electrode construction and its surface coating are discussed in detail. The optimized procedure has permitted to obtain very accurate sensors with detection limit of 0.2 μg (Cd) L−1 using SWASV for only 60 s of deposition time. The electrochemically accessible, i.e. potentially bioavailable, fraction of the cadmium present in an untreated river water sample has been successfully quantified without degassing. These results give a glimpse of the potential of this membrane‐free sensor in real matrices.

Url:
DOI: 10.1002/elan.200900474

Links to Exploration step

ISTEX:D8CF94BDAD41C3EB438C621537C2556213347DD9

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Electroanalytical Device for Cadmium Speciation in Waters. Part 1: Development and Characterization of a Reliable Screen‐Printed Sensor</title>
<author>
<name sortKey="Zaouak, Olivier" sort="Zaouak, Olivier" uniqKey="Zaouak O" first="Olivier" last="Zaouak">Olivier Zaouak</name>
<affiliation>
<mods:affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Authier, Laurent" sort="Authier, Laurent" uniqKey="Authier L" first="Laurent" last="Authier">Laurent Authier</name>
<affiliation>
<mods:affiliation>E-mail: laurent.authier@univ‐pau.fr</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Cugnet, Cyril" sort="Cugnet, Cyril" uniqKey="Cugnet C" first="Cyril" last="Cugnet">Cyril Cugnet</name>
<affiliation>
<mods:affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Castetbon, Alain" sort="Castetbon, Alain" uniqKey="Castetbon A" first="Alain" last="Castetbon">Alain Castetbon</name>
<affiliation>
<mods:affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Potin Autier, Martine" sort="Potin Autier, Martine" uniqKey="Potin Autier M" first="Martine" last="Potin‐Gautier">Martine Potin‐Gautier</name>
<affiliation>
<mods:affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</mods:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:D8CF94BDAD41C3EB438C621537C2556213347DD9</idno>
<date when="2010">2010</date>
<idno type="doi">10.1002/elan.200900474</idno>
<idno type="url">https://api.istex.fr/document/D8CF94BDAD41C3EB438C621537C2556213347DD9/fulltext/pdf</idno>
<idno type="wicri:Area/Main/Corpus">000191</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Electroanalytical Device for Cadmium Speciation in Waters. Part 1: Development and Characterization of a Reliable Screen‐Printed Sensor</title>
<author>
<name sortKey="Zaouak, Olivier" sort="Zaouak, Olivier" uniqKey="Zaouak O" first="Olivier" last="Zaouak">Olivier Zaouak</name>
<affiliation>
<mods:affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Authier, Laurent" sort="Authier, Laurent" uniqKey="Authier L" first="Laurent" last="Authier">Laurent Authier</name>
<affiliation>
<mods:affiliation>E-mail: laurent.authier@univ‐pau.fr</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Cugnet, Cyril" sort="Cugnet, Cyril" uniqKey="Cugnet C" first="Cyril" last="Cugnet">Cyril Cugnet</name>
<affiliation>
<mods:affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Castetbon, Alain" sort="Castetbon, Alain" uniqKey="Castetbon A" first="Alain" last="Castetbon">Alain Castetbon</name>
<affiliation>
<mods:affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Potin Autier, Martine" sort="Potin Autier, Martine" uniqKey="Potin Autier M" first="Martine" last="Potin‐Gautier">Martine Potin‐Gautier</name>
<affiliation>
<mods:affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</mods:affiliation>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Electroanalysis</title>
<title level="j" type="sub">An International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis</title>
<title level="j" type="abbrev">Electroanalysis</title>
<idno type="ISSN">1040-0397</idno>
<imprint>
<publisher>WILEY‐VCH Verlag</publisher>
<pubPlace>Weinheim</pubPlace>
<date type="published" when="2010-06">2010-06</date>
<biblScope unit="vol">22</biblScope>
<biblScope unit="issue">11</biblScope>
<biblScope unit="page" from="1151">1151</biblScope>
<biblScope unit="page" to="1158">1158</biblScope>
</imprint>
<idno type="ISSN">1040-0397</idno>
</series>
<idno type="istex">D8CF94BDAD41C3EB438C621537C2556213347DD9</idno>
<idno type="DOI">10.1002/elan.200900474</idno>
<idno type="ArticleID">ELAN200900474</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">1040-0397</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Cadmium</term>
<term>Real sample</term>
<term>Screen‐printed electrode</term>
<term>Sensors</term>
<term>Speciation</term>
<term>Stripping voltammetry</term>
</keywords>
</textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">A reliable screen‐printed sensor for cadmium speciation analysis is presented here. Its development has been focused on the achievement of a reproducible and repeatable sensor. The electrode construction and its surface coating are discussed in detail. The optimized procedure has permitted to obtain very accurate sensors with detection limit of 0.2 μg (Cd) L−1 using SWASV for only 60 s of deposition time. The electrochemically accessible, i.e. potentially bioavailable, fraction of the cadmium present in an untreated river water sample has been successfully quantified without degassing. These results give a glimpse of the potential of this membrane‐free sensor in real matrices.</div>
</front>
</TEI>
<istex>
<corpusName>wiley</corpusName>
<author>
<json:item>
<name>Olivier Zaouak</name>
<affiliations>
<json:string>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</json:string>
</affiliations>
</json:item>
<json:item>
<name>Laurent Authier</name>
<affiliations>
<json:string>E-mail: laurent.authier@univ‐pau.fr</json:string>
<json:string>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</json:string>
</affiliations>
</json:item>
<json:item>
<name>Cyril Cugnet</name>
<affiliations>
<json:string>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</json:string>
</affiliations>
</json:item>
<json:item>
<name>Alain Castetbon</name>
<affiliations>
<json:string>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</json:string>
</affiliations>
</json:item>
<json:item>
<name>Martine Potin‐Gautier</name>
<affiliations>
<json:string>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</json:string>
</affiliations>
</json:item>
</author>
<subject>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>Stripping voltammetry</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>Screen‐printed electrode</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>Cadmium</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>Speciation</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>Real sample</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>Sensors</value>
</json:item>
</subject>
<language>
<json:string>eng</json:string>
</language>
<abstract>A reliable screen‐printed sensor for cadmium speciation analysis is presented here. Its development has been focused on the achievement of a reproducible and repeatable sensor. The electrode construction and its surface coating are discussed in detail. The optimized procedure has permitted to obtain very accurate sensors with detection limit of 0.2 μg (Cd) L−1 using SWASV for only 60 s of deposition time. The electrochemically accessible, i.e. potentially bioavailable, fraction of the cadmium present in an untreated river water sample has been successfully quantified without degassing. These results give a glimpse of the potential of this membrane‐free sensor in real matrices.</abstract>
<qualityIndicators>
<score>5.639</score>
<pdfVersion>1.3</pdfVersion>
<pdfPageSize>595.276 x 841.89 pts (A4)</pdfPageSize>
<refBibsNative>true</refBibsNative>
<abstractCharCount>685</abstractCharCount>
<pdfWordCount>4451</pdfWordCount>
<pdfCharCount>27276</pdfCharCount>
<pdfPageCount>8</pdfPageCount>
<abstractWordCount>99</abstractWordCount>
</qualityIndicators>
<title>Electroanalytical Device for Cadmium Speciation in Waters. Part 1: Development and Characterization of a Reliable Screen‐Printed Sensor</title>
<genre>
<json:string>article</json:string>
</genre>
<host>
<volume>22</volume>
<pages>
<total>8</total>
<last>1158</last>
<first>1151</first>
</pages>
<issn>
<json:string>1040-0397</json:string>
</issn>
<issue>11</issue>
<subject>
<json:item>
<value>Full Paper</value>
</json:item>
</subject>
<genre></genre>
<language>
<json:string>unknown</json:string>
</language>
<title>Electroanalysis</title>
<doi>
<json:string>10.1002/(ISSN)1521-4109</json:string>
</doi>
</host>
<publicationDate>2010</publicationDate>
<copyrightDate>2010</copyrightDate>
<doi>
<json:string>10.1002/elan.200900474</json:string>
</doi>
<id>D8CF94BDAD41C3EB438C621537C2556213347DD9</id>
<fulltext>
<json:item>
<original>true</original>
<mimetype>application/pdf</mimetype>
<extension>pdf</extension>
<uri>https://api.istex.fr/document/D8CF94BDAD41C3EB438C621537C2556213347DD9/fulltext/pdf</uri>
</json:item>
<json:item>
<original>false</original>
<mimetype>application/zip</mimetype>
<extension>zip</extension>
<uri>https://api.istex.fr/document/D8CF94BDAD41C3EB438C621537C2556213347DD9/fulltext/zip</uri>
</json:item>
<istex:fulltextTEI uri="https://api.istex.fr/document/D8CF94BDAD41C3EB438C621537C2556213347DD9/fulltext/tei">
<teiHeader type="text">
<fileDesc>
<titleStmt>
<title level="a" type="main" xml:lang="en">Electroanalytical Device for Cadmium Speciation in Waters. Part 1: Development and Characterization of a Reliable Screen‐Printed Sensor</title>
</titleStmt>
<publicationStmt>
<authority>ISTEX</authority>
<publisher>WILEY‐VCH Verlag</publisher>
<pubPlace>Weinheim</pubPlace>
<availability>
<p>WILEY‐VCH Verlag</p>
</availability>
<date>2010</date>
</publicationStmt>
<sourceDesc>
<biblStruct type="inbook">
<analytic>
<title level="a" type="main" xml:lang="en">Electroanalytical Device for Cadmium Speciation in Waters. Part 1: Development and Characterization of a Reliable Screen‐Printed Sensor</title>
<author>
<persName>
<forename type="first">Olivier</forename>
<surname>Zaouak</surname>
</persName>
<affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</affiliation>
</author>
<author>
<persName>
<forename type="first">Laurent</forename>
<surname>Authier</surname>
</persName>
<email>laurent.authier@univ‐pau.fr</email>
<affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</affiliation>
</author>
<author>
<persName>
<forename type="first">Cyril</forename>
<surname>Cugnet</surname>
</persName>
<affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</affiliation>
</author>
<author>
<persName>
<forename type="first">Alain</forename>
<surname>Castetbon</surname>
</persName>
<affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</affiliation>
</author>
<author>
<persName>
<forename type="first">Martine</forename>
<surname>Potin‐Gautier</surname>
</persName>
<affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</affiliation>
</author>
</analytic>
<monogr>
<title level="j">Electroanalysis</title>
<title level="j" type="sub">An International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis</title>
<title level="j" type="abbrev">Electroanalysis</title>
<idno type="pISSN">1040-0397</idno>
<idno type="eISSN">1521-4109</idno>
<idno type="DOI">10.1002/(ISSN)1521-4109</idno>
<imprint>
<publisher>WILEY‐VCH Verlag</publisher>
<pubPlace>Weinheim</pubPlace>
<date type="published" when="2010-06"></date>
<biblScope unit="vol">22</biblScope>
<biblScope unit="issue">11</biblScope>
<biblScope unit="page" from="1151">1151</biblScope>
<biblScope unit="page" to="1158">1158</biblScope>
</imprint>
</monogr>
<idno type="istex">D8CF94BDAD41C3EB438C621537C2556213347DD9</idno>
<idno type="DOI">10.1002/elan.200900474</idno>
<idno type="ArticleID">ELAN200900474</idno>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<creation>
<date>2010</date>
</creation>
<langUsage>
<language ident="en">en</language>
</langUsage>
<abstract xml:lang="en">
<p>A reliable screen‐printed sensor for cadmium speciation analysis is presented here. Its development has been focused on the achievement of a reproducible and repeatable sensor. The electrode construction and its surface coating are discussed in detail. The optimized procedure has permitted to obtain very accurate sensors with detection limit of 0.2 μg (Cd) L−1 using SWASV for only 60 s of deposition time. The electrochemically accessible, i.e. potentially bioavailable, fraction of the cadmium present in an untreated river water sample has been successfully quantified without degassing. These results give a glimpse of the potential of this membrane‐free sensor in real matrices.</p>
</abstract>
<textClass xml:lang="en">
<keywords scheme="keyword">
<list>
<head>Keywords</head>
<item>
<term>Stripping voltammetry</term>
</item>
<item>
<term>Screen‐printed electrode</term>
</item>
<item>
<term>Cadmium</term>
</item>
<item>
<term>Speciation</term>
</item>
<item>
<term>Real sample</term>
</item>
<item>
<term>Sensors</term>
</item>
</list>
</keywords>
</textClass>
<textClass>
<keywords scheme="Journal Subject">
<list>
<head>Article category</head>
<item>
<term>Full Paper</term>
</item>
</list>
</keywords>
</textClass>
</profileDesc>
<revisionDesc>
<change when="2009-09-25">Received</change>
<change when="2010-01-04">Registration</change>
<change when="2010-06">Published</change>
</revisionDesc>
</teiHeader>
</istex:fulltextTEI>
<json:item>
<original>false</original>
<mimetype>text/plain</mimetype>
<extension>txt</extension>
<uri>https://api.istex.fr/document/D8CF94BDAD41C3EB438C621537C2556213347DD9/fulltext/txt</uri>
</json:item>
</fulltext>
<metadata>
<istex:metadataXml wicri:clean="Wiley, elements deleted: body">
<istex:xmlDeclaration>version="1.0" encoding="UTF-8" standalone="yes"</istex:xmlDeclaration>
<istex:document>
<component version="2.0" type="serialArticle" xml:lang="en">
<header>
<publicationMeta level="product">
<publisherInfo>
<publisherName>WILEY‐VCH Verlag</publisherName>
<publisherLoc>Weinheim</publisherLoc>
</publisherInfo>
<doi registered="yes">10.1002/(ISSN)1521-4109</doi>
<issn type="print">1040-0397</issn>
<issn type="electronic">1521-4109</issn>
<idGroup>
<id type="product" value="ELAN"></id>
</idGroup>
<titleGroup>
<title type="main" xml:lang="en" sort="ELECTROANALYSIS">Electroanalysis</title>
<title type="subtitle">An International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis</title>
<title type="short">Electroanalysis</title>
</titleGroup>
</publicationMeta>
<publicationMeta level="part" position="110">
<doi origin="wiley" registered="yes">10.1002/elan.v22:11</doi>
<numberingGroup>
<numbering type="journalVolume" number="22">22</numbering>
<numbering type="journalIssue">11</numbering>
</numberingGroup>
<coverDate startDate="2010-06">June 2010</coverDate>
</publicationMeta>
<publicationMeta level="unit" type="article" position="3" status="forIssue">
<doi origin="wiley" registered="yes">10.1002/elan.200900474</doi>
<idGroup>
<id type="unit" value="ELAN200900474"></id>
</idGroup>
<countGroup>
<count type="pageTotal" number="8"></count>
</countGroup>
<titleGroup>
<title type="articleCategory">Full Paper</title>
<title type="tocHeading1">Full Papers</title>
</titleGroup>
<copyright ownership="publisher">Copyright © 2010 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim</copyright>
<eventGroup>
<event type="manuscriptReceived" date="2009-09-25"></event>
<event type="manuscriptAccepted" date="2010-01-04"></event>
<event type="firstOnline" date="2010-03-30"></event>
<event type="publishedOnlineFinalForm" date="2010-05-21"></event>
<event type="xmlConverted" agent="Converter:JWSART34_TO_WML3G version:2.3.6 mode:FullText source:HeaderRef result:HeaderRef" date="2010-05-24"></event>
<event type="xmlConverted" agent="Converter:WILEY_ML3G_TO_WILEY_ML3GV2 version:3.8.8" date="2014-01-24"></event>
<event type="xmlConverted" agent="Converter:WML3G_To_WML3G version:4.1.7 mode:FullText,remove_FC" date="2014-10-16"></event>
</eventGroup>
<numberingGroup>
<numbering type="pageFirst">1151</numbering>
<numbering type="pageLast">1158</numbering>
</numberingGroup>
<linkGroup>
<link type="toTypesetVersion" href="file:ELAN.ELAN200900474.pdf"></link>
</linkGroup>
</publicationMeta>
<contentMeta>
<countGroup>
<count type="figureTotal" number="0"></count>
<count type="tableTotal" number="0"></count>
<count type="referenceTotal" number="32"></count>
</countGroup>
<titleGroup>
<title type="main" xml:lang="en">Electroanalytical Device for Cadmium Speciation in Waters. Part 1: Development and Characterization of a Reliable Screen‐Printed Sensor</title>
</titleGroup>
<creators>
<creator xml:id="au1" creatorRole="author" affiliationRef="#afa">
<personName>
<givenNames>Olivier</givenNames>
<familyName>Zaouak</familyName>
</personName>
</creator>
<creator xml:id="au2" creatorRole="author" affiliationRef="#afa">
<personName>
<givenNames>Laurent</givenNames>
<familyName>Authier</familyName>
</personName>
<contactDetails>
<email normalForm="laurent.authier@univ-pau.fr">laurent.authier@univ‐pau.fr</email>
</contactDetails>
</creator>
<creator xml:id="au3" creatorRole="author" affiliationRef="#afa">
<personName>
<givenNames>Cyril</givenNames>
<familyName>Cugnet</familyName>
</personName>
</creator>
<creator xml:id="au4" creatorRole="author" affiliationRef="#afa">
<personName>
<givenNames>Alain</givenNames>
<familyName>Castetbon</familyName>
</personName>
</creator>
<creator xml:id="au5" creatorRole="author" affiliationRef="#afa">
<personName>
<givenNames>Martine</givenNames>
<familyName>Potin‐Gautier</familyName>
</personName>
</creator>
</creators>
<affiliationGroup>
<affiliation xml:id="afa" countryCode="FR" type="organization">
<unparsedAffiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</unparsedAffiliation>
</affiliation>
</affiliationGroup>
<keywordGroup xml:lang="en" type="author">
<keyword xml:id="kwd1">Stripping voltammetry</keyword>
<keyword xml:id="kwd2">Screen‐printed electrode</keyword>
<keyword xml:id="kwd3">Cadmium</keyword>
<keyword xml:id="kwd4">Speciation</keyword>
<keyword xml:id="kwd5">Real sample</keyword>
<keyword xml:id="kwd6">Sensors</keyword>
</keywordGroup>
<abstractGroup>
<abstract type="main" xml:lang="en">
<title type="main">Abstract</title>
<p>A reliable screen‐printed sensor for cadmium speciation analysis is presented here. Its development has been focused on the achievement of a reproducible and repeatable sensor. The electrode construction and its surface coating are discussed in detail. The optimized procedure has permitted to obtain very accurate sensors with detection limit of 0.2 μg (Cd) L
<sup>−1</sup>
using SWASV for only 60 s of deposition time. The electrochemically accessible, i.e. potentially bioavailable, fraction of the cadmium present in an untreated river water sample has been successfully quantified without degassing. These results give a glimpse of the potential of this membrane‐free sensor in real matrices.</p>
</abstract>
</abstractGroup>
</contentMeta>
</header>
</component>
</istex:document>
</istex:metadataXml>
<!--Version 0.6 générée le 4-12-2015-->
<mods version="3.6">
<titleInfo lang="en">
<title>Electroanalytical Device for Cadmium Speciation in Waters. Part 1: Development and Characterization of a Reliable Screen‐Printed Sensor</title>
</titleInfo>
<titleInfo type="alternative" contentType="CDATA" lang="en">
<title>Electroanalytical Device for Cadmium Speciation in Waters. Part 1: Development and Characterization of a Reliable Screen‐Printed Sensor</title>
</titleInfo>
<name type="personal">
<namePart type="given">Olivier</namePart>
<namePart type="family">Zaouak</namePart>
<affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Laurent</namePart>
<namePart type="family">Authier</namePart>
<affiliation>E-mail: laurent.authier@univ‐pau.fr</affiliation>
<affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Cyril</namePart>
<namePart type="family">Cugnet</namePart>
<affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Alain</namePart>
<namePart type="family">Castetbon</namePart>
<affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Martine</namePart>
<namePart type="family">Potin‐Gautier</namePart>
<affiliation>Université de Pau et des Pays de l'Adour/CNRS, Laboratoire de Chimie Analytique et Bio‐Inorganique UMR 5254 IPREM, 2 avenue Angot, 64053 PAU Cedex 9, France</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<typeOfResource>text</typeOfResource>
<genre authority="originalCategForm">article</genre>
<originInfo>
<publisher>WILEY‐VCH Verlag</publisher>
<place>
<placeTerm type="text">Weinheim</placeTerm>
</place>
<dateIssued encoding="w3cdtf">2010-06</dateIssued>
<dateCaptured encoding="w3cdtf">2009-09-25</dateCaptured>
<dateValid encoding="w3cdtf">2010-01-04</dateValid>
<copyrightDate encoding="w3cdtf">2010</copyrightDate>
</originInfo>
<language>
<languageTerm type="code" authority="rfc3066">en</languageTerm>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<internetMediaType>text/html</internetMediaType>
<extent unit="references">32</extent>
</physicalDescription>
<abstract lang="en">A reliable screen‐printed sensor for cadmium speciation analysis is presented here. Its development has been focused on the achievement of a reproducible and repeatable sensor. The electrode construction and its surface coating are discussed in detail. The optimized procedure has permitted to obtain very accurate sensors with detection limit of 0.2 μg (Cd) L−1 using SWASV for only 60 s of deposition time. The electrochemically accessible, i.e. potentially bioavailable, fraction of the cadmium present in an untreated river water sample has been successfully quantified without degassing. These results give a glimpse of the potential of this membrane‐free sensor in real matrices.</abstract>
<subject lang="en">
<genre>Keywords</genre>
<topic>Stripping voltammetry</topic>
<topic>Screen‐printed electrode</topic>
<topic>Cadmium</topic>
<topic>Speciation</topic>
<topic>Real sample</topic>
<topic>Sensors</topic>
</subject>
<relatedItem type="host">
<titleInfo>
<title>Electroanalysis</title>
<subTitle>An International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis</subTitle>
</titleInfo>
<titleInfo type="abbreviated">
<title>Electroanalysis</title>
</titleInfo>
<subject>
<genre>article category</genre>
<topic>Full Paper</topic>
</subject>
<identifier type="ISSN">1040-0397</identifier>
<identifier type="eISSN">1521-4109</identifier>
<identifier type="DOI">10.1002/(ISSN)1521-4109</identifier>
<identifier type="PublisherID">ELAN</identifier>
<part>
<date>2010</date>
<detail type="volume">
<caption>vol.</caption>
<number>22</number>
</detail>
<detail type="issue">
<caption>no.</caption>
<number>11</number>
</detail>
<extent unit="pages">
<start>1151</start>
<end>1158</end>
<total>8</total>
</extent>
</part>
</relatedItem>
<identifier type="istex">D8CF94BDAD41C3EB438C621537C2556213347DD9</identifier>
<identifier type="DOI">10.1002/elan.200900474</identifier>
<identifier type="ArticleID">ELAN200900474</identifier>
<accessCondition type="use and reproduction" contentType="copyright">Copyright © 2010 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim</accessCondition>
<recordInfo>
<recordOrigin>WILEY‐VCH Verlag</recordOrigin>
<recordContentSource>WILEY</recordContentSource>
</recordInfo>
</mods>
</metadata>
<serie></serie>
</istex>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Terre/explor/CadmiumV1/Data/Main/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000191 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Corpus/biblio.hfd -nk 000191 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Terre
   |area=    CadmiumV1
   |flux=    Main
   |étape=   Corpus
   |type=    RBID
   |clé=     ISTEX:D8CF94BDAD41C3EB438C621537C2556213347DD9
   |texte=   Electroanalytical Device for Cadmium Speciation in Waters. Part 1: Development and Characterization of a Reliable Screen‐Printed Sensor
}}

Wicri

This area was generated with Dilib version V0.6.38.
Data generation: Fri Dec 18 23:53:48 2020. Site generation: Thu Jan 4 21:46:24 2024