E-field assessment errors associated with RF dosemeters for different angles of arrival

Identifieur interne : 005611 ( Istex/Corpus ); précédent : 005610; suivant : 005612

E-field assessment errors associated with RF dosemeters for different angles of arrival

Auteurs : A. Bahillo ; J. Blas ; P. Fernndez ; R. M. Lorenzo ; S. Mazuelas ; E. J. Abril

Source :

RBID : ISTEX:8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A

Abstract

In this paper, an analysis of the surface electric field on a human body based on finite-difference time-domain simulations is presented. A statistical analysis of the dosemeter interaction with the human body has been made by means of the variations of the relative orientation of the human body from the RF source. Variations of the RF source frequency have also been made, by comparing three different services FM, GSM-900 and DCS-1800. Three different scenarios have been simulated where the angle of arrival of the main RF contribution impinges on the human body with a certain probability. Despite the differences between the scenarios, the variations in the electric field strength at each frequency are negligible where the dosemeter would be located.

Url:
DOI: 10.1093/rpd/ncn275

Links to Exploration step

ISTEX:8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title>E-field assessment errors associated with RF dosemeters for different angles of arrival</title>
<author>
<name sortKey="Bahillo, A" sort="Bahillo, A" uniqKey="Bahillo A" first="A." last="Bahillo">A. Bahillo</name>
<affiliation>
<mods:affiliation>CEDETEL, Edificio Solar, Parque Tecnolgico de Boecillo, 47151 Boecillo, Valladolid, Spain</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>E-mail: alfbah@tel.uva.es</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Blas, J" sort="Blas, J" uniqKey="Blas J" first="J." last="Blas">J. Blas</name>
<affiliation>
<mods:affiliation>CEDETEL, Edificio Solar, Parque Tecnolgico de Boecillo, 47151 Boecillo, Valladolid, Spain</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Fernndez, P" sort="Fernndez, P" uniqKey="Fernndez P" first="P." last="Fernndez">P. Fernndez</name>
<affiliation>
<mods:affiliation>Department of Signal Theory and Communications and Telematic Engineering, University of Valladolid, Camino del Cementerio s/n, 47011 Valladolid, Spain</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Lorenzo, R M" sort="Lorenzo, R M" uniqKey="Lorenzo R" first="R. M." last="Lorenzo">R. M. Lorenzo</name>
<affiliation>
<mods:affiliation>Department of Signal Theory and Communications and Telematic Engineering, University of Valladolid, Camino del Cementerio s/n, 47011 Valladolid, Spain</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Mazuelas, S" sort="Mazuelas, S" uniqKey="Mazuelas S" first="S." last="Mazuelas">S. Mazuelas</name>
<affiliation>
<mods:affiliation>CEDETEL, Edificio Solar, Parque Tecnolgico de Boecillo, 47151 Boecillo, Valladolid, Spain</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Abril, E J" sort="Abril, E J" uniqKey="Abril E" first="E. J." last="Abril">E. J. Abril</name>
<affiliation>
<mods:affiliation>Department of Signal Theory and Communications and Telematic Engineering, University of Valladolid, Camino del Cementerio s/n, 47011 Valladolid, Spain</mods:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A</idno>
<date when="2008" year="2008">2008</date>
<idno type="doi">10.1093/rpd/ncn275</idno>
<idno type="url">https://api.istex.fr/document/8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">005611</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">005611</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a">E-field assessment errors associated with RF dosemeters for different angles of arrival</title>
<author>
<name sortKey="Bahillo, A" sort="Bahillo, A" uniqKey="Bahillo A" first="A." last="Bahillo">A. Bahillo</name>
<affiliation>
<mods:affiliation>CEDETEL, Edificio Solar, Parque Tecnolgico de Boecillo, 47151 Boecillo, Valladolid, Spain</mods:affiliation>
</affiliation>
<affiliation>
<mods:affiliation>E-mail: alfbah@tel.uva.es</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Blas, J" sort="Blas, J" uniqKey="Blas J" first="J." last="Blas">J. Blas</name>
<affiliation>
<mods:affiliation>CEDETEL, Edificio Solar, Parque Tecnolgico de Boecillo, 47151 Boecillo, Valladolid, Spain</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Fernndez, P" sort="Fernndez, P" uniqKey="Fernndez P" first="P." last="Fernndez">P. Fernndez</name>
<affiliation>
<mods:affiliation>Department of Signal Theory and Communications and Telematic Engineering, University of Valladolid, Camino del Cementerio s/n, 47011 Valladolid, Spain</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Lorenzo, R M" sort="Lorenzo, R M" uniqKey="Lorenzo R" first="R. M." last="Lorenzo">R. M. Lorenzo</name>
<affiliation>
<mods:affiliation>Department of Signal Theory and Communications and Telematic Engineering, University of Valladolid, Camino del Cementerio s/n, 47011 Valladolid, Spain</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Mazuelas, S" sort="Mazuelas, S" uniqKey="Mazuelas S" first="S." last="Mazuelas">S. Mazuelas</name>
<affiliation>
<mods:affiliation>CEDETEL, Edificio Solar, Parque Tecnolgico de Boecillo, 47151 Boecillo, Valladolid, Spain</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Abril, E J" sort="Abril, E J" uniqKey="Abril E" first="E. J." last="Abril">E. J. Abril</name>
<affiliation>
<mods:affiliation>Department of Signal Theory and Communications and Telematic Engineering, University of Valladolid, Camino del Cementerio s/n, 47011 Valladolid, Spain</mods:affiliation>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Radiation Protection Dosimetry</title>
<idno type="ISSN">0144-8420</idno>
<idno type="eISSN">1742-3406</idno>
<imprint>
<publisher>Oxford University Press</publisher>
<date type="published" when="2008-12">2008-12</date>
<biblScope unit="volume">132</biblScope>
<biblScope unit="issue">1</biblScope>
<biblScope unit="page" from="51">51</biblScope>
<biblScope unit="page" to="56">56</biblScope>
</imprint>
<idno type="ISSN">0144-8420</idno>
</series>
<idno type="istex">8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A</idno>
<idno type="DOI">10.1093/rpd/ncn275</idno>
<idno type="ArticleID">ncn275</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0144-8420</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract">In this paper, an analysis of the surface electric field on a human body based on finite-difference time-domain simulations is presented. A statistical analysis of the dosemeter interaction with the human body has been made by means of the variations of the relative orientation of the human body from the RF source. Variations of the RF source frequency have also been made, by comparing three different services FM, GSM-900 and DCS-1800. Three different scenarios have been simulated where the angle of arrival of the main RF contribution impinges on the human body with a certain probability. Despite the differences between the scenarios, the variations in the electric field strength at each frequency are negligible where the dosemeter would be located.</div>
</front>
</TEI>
<istex>
<corpusName>oup</corpusName>
<author>
<json:item>
<name>A. Bahillo</name>
<affiliations>
<json:string>CEDETEL, Edificio Solar, Parque Tecnolgico de Boecillo, 47151 Boecillo, Valladolid, Spain</json:string>
<json:string>E-mail: alfbah@tel.uva.es</json:string>
</affiliations>
</json:item>
<json:item>
<name>J. Blas</name>
<affiliations>
<json:string>CEDETEL, Edificio Solar, Parque Tecnolgico de Boecillo, 47151 Boecillo, Valladolid, Spain</json:string>
</affiliations>
</json:item>
<json:item>
<name>P. Fernndez</name>
<affiliations>
<json:string>Department of Signal Theory and Communications and Telematic Engineering, University of Valladolid, Camino del Cementerio s/n, 47011 Valladolid, Spain</json:string>
</affiliations>
</json:item>
<json:item>
<name>R. M. Lorenzo</name>
<affiliations>
<json:string>Department of Signal Theory and Communications and Telematic Engineering, University of Valladolid, Camino del Cementerio s/n, 47011 Valladolid, Spain</json:string>
</affiliations>
</json:item>
<json:item>
<name>S. Mazuelas</name>
<affiliations>
<json:string>CEDETEL, Edificio Solar, Parque Tecnolgico de Boecillo, 47151 Boecillo, Valladolid, Spain</json:string>
</affiliations>
</json:item>
<json:item>
<name>E. J. Abril</name>
<affiliations>
<json:string>Department of Signal Theory and Communications and Telematic Engineering, University of Valladolid, Camino del Cementerio s/n, 47011 Valladolid, Spain</json:string>
</affiliations>
</json:item>
</author>
<articleId>
<json:string>ncn275</json:string>
</articleId>
<language>
<json:string>eng</json:string>
</language>
<abstract>In this paper, an analysis of the surface electric field on a human body based on finite-difference time-domain simulations is presented. A statistical analysis of the dosemeter interaction with the human body has been made by means of the variations of the relative orientation of the human body from the RF source. Variations of the RF source frequency have also been made, by comparing three different services FM, GSM-900 and DCS-1800. Three different scenarios have been simulated where the angle of arrival of the main RF contribution impinges on the human body with a certain probability. Despite the differences between the scenarios, the variations in the electric field strength at each frequency are negligible where the dosemeter would be located.</abstract>
<qualityIndicators>
<score>4.295</score>
<pdfVersion>1.2</pdfVersion>
<pdfPageSize>535.748 x 697.323 pts</pdfPageSize>
<refBibsNative>false</refBibsNative>
<keywordCount>0</keywordCount>
<abstractCharCount>759</abstractCharCount>
<pdfWordCount>2855</pdfWordCount>
<pdfCharCount>16399</pdfCharCount>
<pdfPageCount>6</pdfPageCount>
<abstractWordCount>120</abstractWordCount>
</qualityIndicators>
<title>E-field assessment errors associated with RF dosemeters for different angles of arrival</title>
<genre.original>
<json:string>research-article</json:string>
</genre.original>
<genre>
<json:string>research-article</json:string>
</genre>
<host>
<volume>132</volume>
<publisherId>
<json:string>rpd</json:string>
</publisherId>
<pages>
<last>56</last>
<first>51</first>
</pages>
<issn>
<json:string>0144-8420</json:string>
</issn>
<issue>1</issue>
<genre>
<json:string>Journal</json:string>
</genre>
<language>
<json:string>unknown</json:string>
</language>
<eissn>
<json:string>1742-3406</json:string>
</eissn>
<title>Radiation Protection Dosimetry</title>
</host>
<categories>
<wos>
<json:string>NUCLEAR SCIENCE & TECHNOLOGY</json:string>
<json:string>ENVIRONMENTAL SCIENCES</json:string>
<json:string>PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH</json:string>
<json:string>RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING</json:string>
<json:string>REHABILITATION</json:string>
</wos>
</categories>
<publicationDate>2008</publicationDate>
<copyrightDate>2008</copyrightDate>
<doi>
<json:string>10.1093/rpd/ncn275</json:string>
</doi>
<id>8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A</id>
<score>1</score>
<fulltext>
<json:item>
<original>true</original>
<mimetype>application/pdf</mimetype>
<extension>pdf</extension>
<uri>https://api.istex.fr/document/8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A/fulltext/pdf</uri>
</json:item>
<json:item>
<original>false</original>
<mimetype>application/zip</mimetype>
<extension>zip</extension>
<uri>https://api.istex.fr/document/8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A/fulltext/zip</uri>
</json:item>
<istex:fulltextTEI uri="https://api.istex.fr/document/8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A/fulltext/tei">
<teiHeader>
<fileDesc>
<titleStmt>
<title level="a">E-field assessment errors associated with RF dosemeters for different angles of arrival</title>
<respStmt xml:id="ISTEX-API" resp="Références bibliographiques récupérées via GROBID" name="ISTEX-API (INIST-CNRS)"></respStmt>
<respStmt xml:id="ISTEX-API" resp="Références bibliographiques récupérées via GROBID" name="ISTEX-API (INIST-CNRS)"></respStmt>
</titleStmt>
<publicationStmt>
<authority>ISTEX</authority>
<publisher>Oxford University Press</publisher>
<availability>
<p>OUP</p>
</availability>
<date>2008-10-16</date>
</publicationStmt>
<sourceDesc>
<biblStruct type="inbook">
<analytic>
<title level="a">E-field assessment errors associated with RF dosemeters for different angles of arrival</title>
<author>
<persName>
<forename type="first">A.</forename>
<surname>Bahillo</surname>
</persName>
<email>alfbah@tel.uva.es</email>
<affiliation>51 Boecillo, Valladolid, Spain</affiliation>
</author>
<author>
<persName>
<forename type="first">J.</forename>
<surname>Blas</surname>
</persName>
<affiliation>51 Boecillo, Valladolid, Spain</affiliation>
</author>
<author>
<persName>
<forename type="first">P.</forename>
<surname>Fernndez</surname>
</persName>
<affiliation></affiliation>
</author>
<author>
<persName>
<forename type="first">R. M.</forename>
<surname>Lorenzo</surname>
</persName>
<affiliation></affiliation>
</author>
<author>
<persName>
<forename type="first">S.</forename>
<surname>Mazuelas</surname>
</persName>
<affiliation>51 Boecillo, Valladolid, Spain</affiliation>
</author>
<author>
<persName>
<forename type="first">E. J.</forename>
<surname>Abril</surname>
</persName>
<affiliation></affiliation>
</author>
</analytic>
<monogr>
<title level="j">Radiation Protection Dosimetry</title>
<idno type="pISSN">0144-8420</idno>
<idno type="eISSN">1742-3406</idno>
<imprint>
<publisher>Oxford University Press</publisher>
<date type="published" when="2008-12"></date>
<biblScope unit="volume">132</biblScope>
<biblScope unit="issue">1</biblScope>
<biblScope unit="page" from="51">51</biblScope>
<biblScope unit="page" to="56">56</biblScope>
</imprint>
</monogr>
<idno type="istex">8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A</idno>
<idno type="DOI">10.1093/rpd/ncn275</idno>
<idno type="ArticleID">ncn275</idno>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<creation>
<date>2008-10-16</date>
</creation>
<langUsage>
<language ident="en">en</language>
</langUsage>
<abstract>
<p>In this paper, an analysis of the surface electric field on a human body based on finite-difference time-domain simulations is presented. A statistical analysis of the dosemeter interaction with the human body has been made by means of the variations of the relative orientation of the human body from the RF source. Variations of the RF source frequency have also been made, by comparing three different services FM, GSM-900 and DCS-1800. Three different scenarios have been simulated where the angle of arrival of the main RF contribution impinges on the human body with a certain probability. Despite the differences between the scenarios, the variations in the electric field strength at each frequency are negligible where the dosemeter would be located.</p>
</abstract>
</profileDesc>
<revisionDesc>
<change when="2008-10-16">Created</change>
<change when="2008-12">Published</change>
<change xml:id="refBibs-istex" who="#ISTEX-API" when="2016-3-14">References added</change>
<change xml:id="refBibs-istex" who="#ISTEX-API" when="2016-3-21">References added</change>
</revisionDesc>
</teiHeader>
</istex:fulltextTEI>
<json:item>
<original>false</original>
<mimetype>text/plain</mimetype>
<extension>txt</extension>
<uri>https://api.istex.fr/document/8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A/fulltext/txt</uri>
</json:item>
</fulltext>
<metadata>
<istex:metadataXml wicri:clean="corpus oup" wicri:toSee="no header">
<istex:xmlDeclaration>version="1.0" encoding="utf-8"</istex:xmlDeclaration>
<istex:docType PUBLIC="-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" URI="journalpublishing.dtd" name="istex:docType"></istex:docType>
<istex:document>
<article article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">rpd</journal-id>
<journal-id journal-id-type="hwp">rpd</journal-id>
<journal-title>Radiation Protection Dosimetry</journal-title>
<issn pub-type="ppub">0144-8420</issn>
<issn pub-type="epub">1742-3406</issn>
<publisher>
<publisher-name>Oxford University Press</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.1093/rpd/ncn275</article-id>
<article-id pub-id-type="publisher-id">ncn275</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Scientific and Technical Papers</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>E-field assessment errors associated with RF dosemeters for different angles of arrival</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Bahillo</surname>
<given-names>A.</given-names>
</name>
<xref ref-type="aff" rid="af1">1</xref>
<xref ref-type="corresp" rid="cor1">*</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Blas</surname>
<given-names>J.</given-names>
</name>
<xref ref-type="aff" rid="af1">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Fernández</surname>
<given-names>P.</given-names>
</name>
<xref ref-type="aff" rid="af2">2</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Lorenzo</surname>
<given-names>R. M.</given-names>
</name>
<xref ref-type="aff" rid="af2">2</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Mazuelas</surname>
<given-names>S.</given-names>
</name>
<xref ref-type="aff" rid="af1">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Abril</surname>
<given-names>E. J.</given-names>
</name>
<xref ref-type="aff" rid="af2">2</xref>
</contrib>
</contrib-group>
<aff id="af1">
<label>1</label>
<addr-line>CEDETEL, Edificio Solar, Parque Tecnológico de Boecillo, 47151 Boecillo, Valladolid</addr-line>
,
<country>Spain</country>
</aff>
<aff id="af2">
<label>2</label>
<addr-line>Department of Signal Theory and Communications and Telematic Engineering</addr-line>
,
<institution>University of Valladolid</institution>
,
<addr-line>Camino del Cementerio s/n, 47011 Valladolid</addr-line>
,
<country>Spain</country>
</aff>
<author-notes>
<corresp id="cor1">
<label>*</label>
Corresponding author:
<email>alfbah@tel.uva.es</email>
;
<email>abahillo@cedetel.es</email>
</corresp>
</author-notes>
<pub-date pub-type="ppub">
<month>12</month>
<year>2008</year>
</pub-date>
<pub-date pub-type="epub">
<day>16</day>
<month>10</month>
<year>2008</year>
</pub-date>
<volume>132</volume>
<issue>1</issue>
<fpage>51</fpage>
<lpage>56</lpage>
<history>
<date date-type="received">
<day>15</day>
<month>7</month>
<year>2008</year>
</date>
<date date-type="rev-recd">
<day>16</day>
<month>9</month>
<year>2008</year>
</date>
<date date-type="accepted">
<day>18</day>
<month>9</month>
<year>2008</year>
</date>
</history>
<copyright-statement>© The Author 2008. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org</copyright-statement>
<copyright-year>2008</copyright-year>
<abstract>
<p>In this paper, an analysis of the surface electric field on a human body based on finite-difference time-domain simulations is presented. A statistical analysis of the dosemeter interaction with the human body has been made by means of the variations of the relative orientation of the human body from the RF source. Variations of the RF source frequency have also been made, by comparing three different services FM, GSM-900 and DCS-1800. Three different scenarios have been simulated where the angle of arrival of the main RF contribution impinges on the human body with a certain probability. Despite the differences between the scenarios, the variations in the electric field strength at each frequency are negligible where the dosemeter would be located.</p>
</abstract>
</article-meta>
</front>
</article>
</istex:document>
</istex:metadataXml>
<mods version="3.6">
<titleInfo>
<title>E-field assessment errors associated with RF dosemeters for different angles of arrival</title>
</titleInfo>
<titleInfo type="alternative" contentType="CDATA">
<title>E-field assessment errors associated with RF dosemeters for different angles of arrival</title>
</titleInfo>
<name type="personal">
<namePart type="given">A.</namePart>
<namePart type="family">Bahillo</namePart>
<affiliation>CEDETEL, Edificio Solar, Parque Tecnolgico de Boecillo, 47151 Boecillo, Valladolid, Spain</affiliation>
<affiliation>E-mail: alfbah@tel.uva.es</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">J.</namePart>
<namePart type="family">Blas</namePart>
<affiliation>CEDETEL, Edificio Solar, Parque Tecnolgico de Boecillo, 47151 Boecillo, Valladolid, Spain</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">P.</namePart>
<namePart type="family">Fernndez</namePart>
<affiliation>Department of Signal Theory and Communications and Telematic Engineering, University of Valladolid, Camino del Cementerio s/n, 47011 Valladolid, Spain</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">R. M.</namePart>
<namePart type="family">Lorenzo</namePart>
<affiliation>Department of Signal Theory and Communications and Telematic Engineering, University of Valladolid, Camino del Cementerio s/n, 47011 Valladolid, Spain</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">S.</namePart>
<namePart type="family">Mazuelas</namePart>
<affiliation>CEDETEL, Edificio Solar, Parque Tecnolgico de Boecillo, 47151 Boecillo, Valladolid, Spain</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">E. J.</namePart>
<namePart type="family">Abril</namePart>
<affiliation>Department of Signal Theory and Communications and Telematic Engineering, University of Valladolid, Camino del Cementerio s/n, 47011 Valladolid, Spain</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<typeOfResource>text</typeOfResource>
<genre type="research-article" displayLabel="research-article"></genre>
<originInfo>
<publisher>Oxford University Press</publisher>
<dateIssued encoding="w3cdtf">2008-12</dateIssued>
<dateCreated encoding="w3cdtf">2008-10-16</dateCreated>
<copyrightDate encoding="w3cdtf">2008</copyrightDate>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
<languageTerm type="code" authority="rfc3066">en</languageTerm>
</language>
<physicalDescription>
<internetMediaType>text/html</internetMediaType>
</physicalDescription>
<abstract>In this paper, an analysis of the surface electric field on a human body based on finite-difference time-domain simulations is presented. A statistical analysis of the dosemeter interaction with the human body has been made by means of the variations of the relative orientation of the human body from the RF source. Variations of the RF source frequency have also been made, by comparing three different services FM, GSM-900 and DCS-1800. Three different scenarios have been simulated where the angle of arrival of the main RF contribution impinges on the human body with a certain probability. Despite the differences between the scenarios, the variations in the electric field strength at each frequency are negligible where the dosemeter would be located.</abstract>
<relatedItem type="host">
<titleInfo>
<title>Radiation Protection Dosimetry</title>
</titleInfo>
<genre type="Journal">journal</genre>
<identifier type="ISSN">0144-8420</identifier>
<identifier type="eISSN">1742-3406</identifier>
<identifier type="PublisherID">rpd</identifier>
<identifier type="PublisherID-hwp">rpd</identifier>
<part>
<date>2008</date>
<detail type="volume">
<caption>vol.</caption>
<number>132</number>
</detail>
<detail type="issue">
<caption>no.</caption>
<number>1</number>
</detail>
<extent unit="pages">
<start>51</start>
<end>56</end>
</extent>
</part>
</relatedItem>
<identifier type="istex">8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A</identifier>
<identifier type="DOI">10.1093/rpd/ncn275</identifier>
<identifier type="ArticleID">ncn275</identifier>
<accessCondition type="use and reproduction" contentType="copyright">The Author 2008. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissionsoxfordjournals.org</accessCondition>
<recordInfo>
<recordContentSource>OUP</recordContentSource>
</recordInfo>
</mods>
</metadata>
<covers>
<json:item>
<original>true</original>
<mimetype>image/tiff</mimetype>
<extension>tiff</extension>
<uri>https://api.istex.fr/document/8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A/covers/tiff</uri>
</json:item>
</covers>
<annexes>
<json:item>
<original>true</original>
<mimetype>image/jpeg</mimetype>
<extension>jpeg</extension>
<uri>https://api.istex.fr/document/8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A/annexes/jpeg</uri>
</json:item>
<json:item>
<original>true</original>
<mimetype>image/gif</mimetype>
<extension>gif</extension>
<uri>https://api.istex.fr/document/8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A/annexes/gif</uri>
</json:item>
<json:item>
<original>true</original>
<mimetype>application/pdf</mimetype>
<extension>pdf</extension>
<uri>https://api.istex.fr/document/8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A/annexes/pdf</uri>
</json:item>
</annexes>
<serie></serie>
</istex>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/TelematiV1/Data/Istex/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 005611 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Corpus/biblio.hfd -nk 005611 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    TelematiV1
   |flux=    Istex
   |étape=   Corpus
   |type=    RBID
   |clé=     ISTEX:8DD6F023A8FB4D26889DE1669D5B00A9B266FD4A
   |texte=   E-field assessment errors associated with RF dosemeters for different angles of arrival
}}

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Thu Nov 2 16:09:04 2017. Site generation: Sun Mar 10 16:42:28 2024