Development in a Windows environment of a radiation treatment planning system for personal computers

Identifieur interne : 002133 ( Main/Exploration ); précédent : 002132; suivant : 002134

Development in a Windows environment of a radiation treatment planning system for personal computers

Auteurs : C. Cotrutz [Roumanie] ; C. Kappas [Grèce] ; Y. Theodorakos [Grèce] ; C. Makris [Grèce] ; R. Mohan [États-Unis]

Source :

RBID : ISTEX:3060636184A40B9025092FA17872E49838F5BEE8

Abstract

A new personal computer (PC) radiotherapy treatment planning system (RTPS) is presented. The PC-based RTPS is designed to run in the Microsoft Windows 3.11 environment (and later versions), for computers equipped with 486 or Pentium processors. The algorithm used by the new PC-based program for dose calculation belongs to the `radiological pathlength' category and it was previously implemented on VAX 711 computers at Memorial Sloan-Kettering Cancer Center (MSKCC) in New York, NY, within EXTREP-III RTPS. The EXTREP-III program is a two-dimensional RTPS (with restricted three-dimensional capabilities), developed and used in clinical practice at MSKCC during the 1980s. The PC-based program is implemented in the Visual Basic (version 3.0) language and supports features commonly available in most photon-mode RTPSs: dose calculation for fixed, isocentric and rotational irradiation techniques, dose corrections for both internal inhomogeneities and external inhomogeneities (boluses and compensators), association of machine-specific beams with various wedges and blocks, etc. The graphic interface of the PC-based RTPS is completely new and is designed to meet the requirements of fast and accurate planning. The user interface consists of an event-oriented button-based console which allows users to perform planning and to have isodose charts overlaid on patient computed tomography images initially loaded in the program. The PC-based RTPS tests, performed in order to assess its accuracy and speed of computation, show good results. The acceptable computation times obtained, the good accuracy in dose computation and the user-friendly interface of the program are sufficient reasons to consider the PC-based RTPS a good quality–price ratio tool for radiation treatment planning in cancer therapy.

Url:
DOI: 10.1016/S0169-2607(98)00029-7


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title>Development in a Windows environment of a radiation treatment planning system for personal computers</title>
<author>
<name sortKey="Cotrutz, C" sort="Cotrutz, C" uniqKey="Cotrutz C" first="C." last="Cotrutz">C. Cotrutz</name>
</author>
<author>
<name sortKey="Kappas, C" sort="Kappas, C" uniqKey="Kappas C" first="C." last="Kappas">C. Kappas</name>
</author>
<author>
<name sortKey="Theodorakos, Y" sort="Theodorakos, Y" uniqKey="Theodorakos Y" first="Y." last="Theodorakos">Y. Theodorakos</name>
</author>
<author>
<name sortKey="Makris, C" sort="Makris, C" uniqKey="Makris C" first="C." last="Makris">C. Makris</name>
</author>
<author>
<name sortKey="Mohan, R" sort="Mohan, R" uniqKey="Mohan R" first="R." last="Mohan">R. Mohan</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:3060636184A40B9025092FA17872E49838F5BEE8</idno>
<date when="1998" year="1998">1998</date>
<idno type="doi">10.1016/S0169-2607(98)00029-7</idno>
<idno type="url">https://api.istex.fr/document/3060636184A40B9025092FA17872E49838F5BEE8/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000187</idno>
<idno type="wicri:Area/Istex/Curation">000184</idno>
<idno type="wicri:Area/Istex/Checkpoint">001637</idno>
<idno type="wicri:doubleKey">0169-2607:1998:Cotrutz C:development:in:a</idno>
<idno type="wicri:Area/Main/Merge">002250</idno>
<idno type="wicri:Area/Main/Curation">002133</idno>
<idno type="wicri:Area/Main/Exploration">002133</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a">Development in a Windows environment of a radiation treatment planning system for personal computers</title>
<author>
<name sortKey="Cotrutz, C" sort="Cotrutz, C" uniqKey="Cotrutz C" first="C." last="Cotrutz">C. Cotrutz</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Roumanie</country>
<wicri:regionArea>Medical Physics Department, Faculty of Physics, `Alex. I. Cuza' University, R-6600 Iasi</wicri:regionArea>
<wicri:noRegion>R-6600 Iasi</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Kappas, C" sort="Kappas, C" uniqKey="Kappas C" first="C." last="Kappas">C. Kappas</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Grèce</country>
<wicri:regionArea>Medical Physics Department, Faculty of Medicine, University of Patras, GR-26500 Patras, Hellas</wicri:regionArea>
<wicri:noRegion>Hellas</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Theodorakos, Y" sort="Theodorakos, Y" uniqKey="Theodorakos Y" first="Y." last="Theodorakos">Y. Theodorakos</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Grèce</country>
<wicri:regionArea>Medical Physics Department, Faculty of Medicine, University of Patras, GR-26500 Patras, Hellas</wicri:regionArea>
<wicri:noRegion>Hellas</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Makris, C" sort="Makris, C" uniqKey="Makris C" first="C." last="Makris">C. Makris</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Grèce</country>
<wicri:regionArea>Medical Physics Department, Faculty of Medicine, University of Patras, GR-26500 Patras, Hellas</wicri:regionArea>
<wicri:noRegion>Hellas</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Mohan, R" sort="Mohan, R" uniqKey="Mohan R" first="R." last="Mohan">R. Mohan</name>
<affiliation wicri:level="2">
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York City, NY 10021</wicri:regionArea>
<placeName>
<region type="state">État de New York</region>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Computer Methods and Programs in Biomedicine</title>
<title level="j" type="abbrev">COMM</title>
<idno type="ISSN">0169-2607</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1998">1998</date>
<biblScope unit="volume">56</biblScope>
<biblScope unit="issue">3</biblScope>
<biblScope unit="page" from="261">261</biblScope>
<biblScope unit="page" to="272">272</biblScope>
</imprint>
<idno type="ISSN">0169-2607</idno>
</series>
<idno type="istex">3060636184A40B9025092FA17872E49838F5BEE8</idno>
<idno type="DOI">10.1016/S0169-2607(98)00029-7</idno>
<idno type="PII">S0169-2607(98)00029-7</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0169-2607</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">A new personal computer (PC) radiotherapy treatment planning system (RTPS) is presented. The PC-based RTPS is designed to run in the Microsoft Windows 3.11 environment (and later versions), for computers equipped with 486 or Pentium processors. The algorithm used by the new PC-based program for dose calculation belongs to the `radiological pathlength' category and it was previously implemented on VAX 711 computers at Memorial Sloan-Kettering Cancer Center (MSKCC) in New York, NY, within EXTREP-III RTPS. The EXTREP-III program is a two-dimensional RTPS (with restricted three-dimensional capabilities), developed and used in clinical practice at MSKCC during the 1980s. The PC-based program is implemented in the Visual Basic (version 3.0) language and supports features commonly available in most photon-mode RTPSs: dose calculation for fixed, isocentric and rotational irradiation techniques, dose corrections for both internal inhomogeneities and external inhomogeneities (boluses and compensators), association of machine-specific beams with various wedges and blocks, etc. The graphic interface of the PC-based RTPS is completely new and is designed to meet the requirements of fast and accurate planning. The user interface consists of an event-oriented button-based console which allows users to perform planning and to have isodose charts overlaid on patient computed tomography images initially loaded in the program. The PC-based RTPS tests, performed in order to assess its accuracy and speed of computation, show good results. The acceptable computation times obtained, the good accuracy in dose computation and the user-friendly interface of the program are sufficient reasons to consider the PC-based RTPS a good quality–price ratio tool for radiation treatment planning in cancer therapy.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Grèce</li>
<li>Roumanie</li>
<li>États-Unis</li>
</country>
<region>
<li>État de New York</li>
</region>
</list>
<tree>
<country name="Roumanie">
<noRegion>
<name sortKey="Cotrutz, C" sort="Cotrutz, C" uniqKey="Cotrutz C" first="C." last="Cotrutz">C. Cotrutz</name>
</noRegion>
</country>
<country name="Grèce">
<noRegion>
<name sortKey="Kappas, C" sort="Kappas, C" uniqKey="Kappas C" first="C." last="Kappas">C. Kappas</name>
</noRegion>
<name sortKey="Makris, C" sort="Makris, C" uniqKey="Makris C" first="C." last="Makris">C. Makris</name>
<name sortKey="Theodorakos, Y" sort="Theodorakos, Y" uniqKey="Theodorakos Y" first="Y." last="Theodorakos">Y. Theodorakos</name>
</country>
<country name="États-Unis">
<region name="État de New York">
<name sortKey="Mohan, R" sort="Mohan, R" uniqKey="Mohan R" first="R." last="Mohan">R. Mohan</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/OcrV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002133 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 002133 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    OcrV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:3060636184A40B9025092FA17872E49838F5BEE8
   |texte=   Development in a Windows environment of a radiation treatment planning system for personal computers
}}

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Sat Nov 11 16:53:45 2017. Site generation: Mon Mar 11 23:15:16 2024