A modified iris fixation suture utilizing a peripheral iridectomy.
Identifieur interne : 002240 ( PubMed/Curation ); précédent : 002239; suivant : 002241A modified iris fixation suture utilizing a peripheral iridectomy.
Auteurs : R W AllinsonSource :
- Ophthalmic surgery [ 0022-023X ] ; 1990.
English descriptors
- KwdEn :
- MESH :
- surgery : Iris.
- Aged, Humans, Lenses, Intraocular, Male, Suture Techniques.
Abstract
To help ensure proper placement of an iris fixation suture, a peripheral iridectomy can be performed to allow visualization of the superior haptic of a posterior chamber intraocular lens (PC-IOL). In cases where support for the PC-IOL is in question, an iris fixation suture using this technique provides an easy way of ensuring adequate support.
PubMed: 2190132
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: Pour aller vers cette notice dans l'étape Curation :002240
Links to Exploration step
pubmed:2190132Curation
No country items
R W Allinson<affiliation><nlm:affiliation>Department of Ophthalmology, College of Medicine, University of Arizona, Tuscon 85724.</nlm:affiliation>
<wicri:noCountry code="subField">Tuscon 85724</wicri:noCountry>
</affiliation>
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">A modified iris fixation suture utilizing a peripheral iridectomy.</title>
<author><name sortKey="Allinson, R W" sort="Allinson, R W" uniqKey="Allinson R" first="R W" last="Allinson">R W Allinson</name>
<affiliation><nlm:affiliation>Department of Ophthalmology, College of Medicine, University of Arizona, Tuscon 85724.</nlm:affiliation>
<wicri:noCountry code="subField">Tuscon 85724</wicri:noCountry>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="1990">1990</date>
<idno type="RBID">pubmed:2190132</idno>
<idno type="pmid">2190132</idno>
<idno type="wicri:Area/PubMed/Corpus">002240</idno>
<idno type="wicri:Area/PubMed/Curation">002240</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">A modified iris fixation suture utilizing a peripheral iridectomy.</title>
<author><name sortKey="Allinson, R W" sort="Allinson, R W" uniqKey="Allinson R" first="R W" last="Allinson">R W Allinson</name>
<affiliation><nlm:affiliation>Department of Ophthalmology, College of Medicine, University of Arizona, Tuscon 85724.</nlm:affiliation>
<wicri:noCountry code="subField">Tuscon 85724</wicri:noCountry>
</affiliation>
</author>
</analytic>
<series><title level="j">Ophthalmic surgery</title>
<idno type="ISSN">0022-023X</idno>
<imprint><date when="1990" type="published">1990</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Aged</term>
<term>Humans</term>
<term>Iris (surgery)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Suture Techniques</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en"><term>Iris</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Aged</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Suture Techniques</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">To help ensure proper placement of an iris fixation suture, a peripheral iridectomy can be performed to allow visualization of the superior haptic of a posterior chamber intraocular lens (PC-IOL). In cases where support for the PC-IOL is in question, an iris fixation suture using this technique provides an easy way of ensuring adequate support.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">2190132</PMID>
<DateCreated><Year>1990</Year>
<Month>07</Month>
<Day>11</Day>
</DateCreated>
<DateCompleted><Year>1990</Year>
<Month>07</Month>
<Day>11</Day>
</DateCompleted>
<DateRevised><Year>2004</Year>
<Month>11</Month>
<Day>17</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0022-023X</ISSN>
<JournalIssue CitedMedium="Print"><Volume>21</Volume>
<Issue>3</Issue>
<PubDate><Year>1990</Year>
<Month>Mar</Month>
</PubDate>
</JournalIssue>
<Title>Ophthalmic surgery</Title>
<ISOAbbreviation>Ophthalmic Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>A modified iris fixation suture utilizing a peripheral iridectomy.</ArticleTitle>
<Pagination><MedlinePgn>213-4</MedlinePgn>
</Pagination>
<Abstract><AbstractText>To help ensure proper placement of an iris fixation suture, a peripheral iridectomy can be performed to allow visualization of the superior haptic of a posterior chamber intraocular lens (PC-IOL). In cases where support for the PC-IOL is in question, an iris fixation suture using this technique provides an easy way of ensuring adequate support.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Allinson</LastName>
<ForeName>R W</ForeName>
<Initials>RW</Initials>
<AffiliationInfo><Affiliation>Department of Ophthalmology, College of Medicine, University of Arizona, Tuscon 85724.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D002363">Case Reports</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>UNITED STATES</Country>
<MedlineTA>Ophthalmic Surg</MedlineTA>
<NlmUniqueID>0241035</NlmUniqueID>
<ISSNLinking>0022-023X</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D007498">Iris</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D013536">Suture Techniques</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="pubmed"><Year>1990</Year>
<Month>3</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>1990</Year>
<Month>3</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>1990</Year>
<Month>3</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">2190132</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002240 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 002240 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Curation |type= RBID |clé= pubmed:2190132 |texte= A modified iris fixation suture utilizing a peripheral iridectomy. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i -Sk "pubmed:2190132" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
![]() | This area was generated with Dilib version V0.6.23. | ![]() |