Ocular damage after implantation of oversized minus power anterior chamber intraocular lenses in myopic phakic eyes: case reports.
Identifieur interne : 002165 ( PubMed/Curation ); précédent : 002164; suivant : 002166Ocular damage after implantation of oversized minus power anterior chamber intraocular lenses in myopic phakic eyes: case reports.
Auteurs : J J Saragoussi [France] ; P. Othenin-Girard ; Y J PouliquenSource :
- Refractive & corneal surgery [ 1042-962X ]
English descriptors
- KwdEn :
- MESH :
- adverse effects : Lenses, Intraocular, Prosthesis Design.
- etiology : Endophthalmitis, Eye Diseases.
- surgery : Anterior Chamber, Myopia.
- Adult, Anterior Eye Segment, Female, Humans, Lens, Crystalline, Male, Visual Acuity.
Abstract
Positioning in the iridocorneal angle is one of the factors determining long-term tolerance of anterior chamber intraocular lenses (IOLs). This problem has again become topical with the use of myopic IOLs with angular supports.
PubMed: 8494809
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: Pour aller vers cette notice dans l'étape Curation :002165
Links to Exploration step
pubmed:8494809Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Ocular damage after implantation of oversized minus power anterior chamber intraocular lenses in myopic phakic eyes: case reports.</title>
<author><name sortKey="Saragoussi, J J" sort="Saragoussi, J J" uniqKey="Saragoussi J" first="J J" last="Saragoussi">J J Saragoussi</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Ophthalmology, Hotel-Dieu Hospital, Paris, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Department of Ophthalmology, Hotel-Dieu Hospital, Paris</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Othenin Girard, P" sort="Othenin Girard, P" uniqKey="Othenin Girard P" first="P" last="Othenin-Girard">P. Othenin-Girard</name>
</author>
<author><name sortKey="Pouliquen, Y J" sort="Pouliquen, Y J" uniqKey="Pouliquen Y" first="Y J" last="Pouliquen">Y J Pouliquen</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="????"><PubDate><MedlineDate>1993 Mar-Apr</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:8494809</idno>
<idno type="pmid">8494809</idno>
<idno type="wicri:Area/PubMed/Corpus">002165</idno>
<idno type="wicri:Area/PubMed/Curation">002165</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Ocular damage after implantation of oversized minus power anterior chamber intraocular lenses in myopic phakic eyes: case reports.</title>
<author><name sortKey="Saragoussi, J J" sort="Saragoussi, J J" uniqKey="Saragoussi J" first="J J" last="Saragoussi">J J Saragoussi</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Ophthalmology, Hotel-Dieu Hospital, Paris, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Department of Ophthalmology, Hotel-Dieu Hospital, Paris</wicri:regionArea>
</affiliation>
</author>
<author><name sortKey="Othenin Girard, P" sort="Othenin Girard, P" uniqKey="Othenin Girard P" first="P" last="Othenin-Girard">P. Othenin-Girard</name>
</author>
<author><name sortKey="Pouliquen, Y J" sort="Pouliquen, Y J" uniqKey="Pouliquen Y" first="Y J" last="Pouliquen">Y J Pouliquen</name>
</author>
</analytic>
<series><title level="j">Refractive & corneal surgery</title>
<idno type="ISSN">1042-962X</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Adult</term>
<term>Anterior Chamber (surgery)</term>
<term>Anterior Eye Segment</term>
<term>Endophthalmitis (etiology)</term>
<term>Eye Diseases (etiology)</term>
<term>Female</term>
<term>Humans</term>
<term>Lens, Crystalline</term>
<term>Lenses, Intraocular (adverse effects)</term>
<term>Male</term>
<term>Myopia (surgery)</term>
<term>Prosthesis Design (adverse effects)</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en"><term>Lenses, Intraocular</term>
<term>Prosthesis Design</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en"><term>Endophthalmitis</term>
<term>Eye Diseases</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en"><term>Anterior Chamber</term>
<term>Myopia</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Adult</term>
<term>Anterior Eye Segment</term>
<term>Female</term>
<term>Humans</term>
<term>Lens, Crystalline</term>
<term>Male</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Positioning in the iridocorneal angle is one of the factors determining long-term tolerance of anterior chamber intraocular lenses (IOLs). This problem has again become topical with the use of myopic IOLs with angular supports.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">8494809</PMID>
<DateCreated><Year>1993</Year>
<Month>06</Month>
<Day>22</Day>
</DateCreated>
<DateCompleted><Year>1993</Year>
<Month>06</Month>
<Day>22</Day>
</DateCompleted>
<DateRevised><Year>2004</Year>
<Month>11</Month>
<Day>17</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">1042-962X</ISSN>
<JournalIssue CitedMedium="Print"><Volume>9</Volume>
<Issue>2</Issue>
<PubDate><MedlineDate>1993 Mar-Apr</MedlineDate>
</PubDate>
</JournalIssue>
<Title>Refractive & corneal surgery</Title>
<ISOAbbreviation>Refract Corneal Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Ocular damage after implantation of oversized minus power anterior chamber intraocular lenses in myopic phakic eyes: case reports.</ArticleTitle>
<Pagination><MedlinePgn>105-9</MedlinePgn>
</Pagination>
<Abstract><AbstractText Label="BACKGROUND" NlmCategory="BACKGROUND">Positioning in the iridocorneal angle is one of the factors determining long-term tolerance of anterior chamber intraocular lenses (IOLs). This problem has again become topical with the use of myopic IOLs with angular supports.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">The authors describe three eyes illustrating the possible complications resulting from the insertion of oversized minus power anterior chamber implants in myopic phakic eyes.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The complications developed early or late after surgery. They consisted mainly of inflammatory reactions, stable or progressive pupillary deformation, and adherence of the iris to the implant.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">In myopic phakic eyes, the insertion of incorrectly sized IOLs with angular supports may cause complications which have already been reported for anterior chamber implants in aphakic eyes. Haptic flexibility does not always make up for incorrect sizing due to imprecise preoperative evaluation of iridocorneal angle diameter.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Saragoussi</LastName>
<ForeName>J J</ForeName>
<Initials>JJ</Initials>
<AffiliationInfo><Affiliation>Department of Ophthalmology, Hotel-Dieu Hospital, Paris, France.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Othenin-Girard</LastName>
<ForeName>P</ForeName>
<Initials>P</Initials>
</Author>
<Author ValidYN="Y"><LastName>Pouliquen</LastName>
<ForeName>Y J</ForeName>
<Initials>YJ</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D002363">Case Reports</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>UNITED STATES</Country>
<MedlineTA>Refract Corneal Surg</MedlineTA>
<NlmUniqueID>8908429</NlmUniqueID>
<ISSNLinking>1042-962X</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D000867">Anterior Chamber</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D000869">Anterior Eye Segment</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D009877">Endophthalmitis</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000209">etiology</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D005128">Eye Diseases</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000209">etiology</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D007908">Lens, Crystalline</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D007910">Lenses, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000009">adverse effects</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D009216">Myopia</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D011474">Prosthesis Design</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000009">adverse effects</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D014792">Visual Acuity</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="pubmed"><Year>1993</Year>
<Month>3</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>1993</Year>
<Month>3</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>1993</Year>
<Month>3</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">8494809</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002165 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 002165 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Curation |type= RBID |clé= pubmed:8494809 |texte= Ocular damage after implantation of oversized minus power anterior chamber intraocular lenses in myopic phakic eyes: case reports. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i -Sk "pubmed:8494809" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
![]() | This area was generated with Dilib version V0.6.23. | ![]() |