Effect of folding instruments on silicone intraocular lenses.
Identifieur interne : 002128 ( PubMed/Curation ); précédent : 002127; suivant : 002129Effect of folding instruments on silicone intraocular lenses.
Auteurs : D G Brady [États-Unis] ; J E Giamporcaro ; R F SteinertSource :
- Journal of cataract and refractive surgery [ 0886-3350 ] ; 1994.
English descriptors
- KwdEn :
- MESH :
- chemical , chemistry : Silicone Elastomers.
- instrumentation : Cataract Extraction, Lenses, Intraocular.
- Humans, Microscopy, Electron, Scanning, Optics and Photonics, Surface Properties.
Abstract
The Faulkner holding and folding forceps, the Fine folder, and the Prodigy inserter (PRO-1A) were evaluated to assess their effects on silicone intraocular lenses (IOLS) after the lenses were folded. The IOLs were evaluated before folding and at two and 24 hours after folding for haptic dimension, optic quality, and surface quality. None of the instruments caused a clinically important effect on the IOLs 24 hours after folding. The cross-sectional area required for IOL insertion was calculated for each folder. The Prodigy required the smallest cross-sectional area and the Faulkner the largest when folding a 24 diopter lens. We also describe a protocol that can be used to evaluate new IOL folders.
PubMed: 8064608
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: Pour aller vers cette notice dans l'étape Curation :002128
Links to Exploration step
pubmed:8064608Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Effect of folding instruments on silicone intraocular lenses.</title>
<author><name sortKey="Brady, D G" sort="Brady, D G" uniqKey="Brady D" first="D G" last="Brady">D G Brady</name>
<affiliation wicri:level="2"><nlm:affiliation>Research and Development Department, Allergan Medical Optics, Irvine, California 92718.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<placeName><region type="state">Californie</region>
</placeName>
<wicri:cityArea>Research and Development Department, Allergan Medical Optics, Irvine</wicri:cityArea>
</affiliation>
</author>
<author><name sortKey="Giamporcaro, J E" sort="Giamporcaro, J E" uniqKey="Giamporcaro J" first="J E" last="Giamporcaro">J E Giamporcaro</name>
</author>
<author><name sortKey="Steinert, R F" sort="Steinert, R F" uniqKey="Steinert R" first="R F" last="Steinert">R F Steinert</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="1994">1994</date>
<idno type="RBID">pubmed:8064608</idno>
<idno type="pmid">8064608</idno>
<idno type="wicri:Area/PubMed/Corpus">002128</idno>
<idno type="wicri:Area/PubMed/Curation">002128</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Effect of folding instruments on silicone intraocular lenses.</title>
<author><name sortKey="Brady, D G" sort="Brady, D G" uniqKey="Brady D" first="D G" last="Brady">D G Brady</name>
<affiliation wicri:level="2"><nlm:affiliation>Research and Development Department, Allergan Medical Optics, Irvine, California 92718.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<placeName><region type="state">Californie</region>
</placeName>
<wicri:cityArea>Research and Development Department, Allergan Medical Optics, Irvine</wicri:cityArea>
</affiliation>
</author>
<author><name sortKey="Giamporcaro, J E" sort="Giamporcaro, J E" uniqKey="Giamporcaro J" first="J E" last="Giamporcaro">J E Giamporcaro</name>
</author>
<author><name sortKey="Steinert, R F" sort="Steinert, R F" uniqKey="Steinert R" first="R F" last="Steinert">R F Steinert</name>
</author>
</analytic>
<series><title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint><date when="1994" type="published">1994</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Cataract Extraction (instrumentation)</term>
<term>Humans</term>
<term>Lenses, Intraocular (instrumentation)</term>
<term>Microscopy, Electron, Scanning</term>
<term>Optics and Photonics</term>
<term>Silicone Elastomers (chemistry)</term>
<term>Surface Properties</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="chemistry" xml:lang="en"><term>Silicone Elastomers</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en"><term>Cataract Extraction</term>
<term>Lenses, Intraocular</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Humans</term>
<term>Microscopy, Electron, Scanning</term>
<term>Optics and Photonics</term>
<term>Surface Properties</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The Faulkner holding and folding forceps, the Fine folder, and the Prodigy inserter (PRO-1A) were evaluated to assess their effects on silicone intraocular lenses (IOLS) after the lenses were folded. The IOLs were evaluated before folding and at two and 24 hours after folding for haptic dimension, optic quality, and surface quality. None of the instruments caused a clinically important effect on the IOLs 24 hours after folding. The cross-sectional area required for IOL insertion was calculated for each folder. The Prodigy required the smallest cross-sectional area and the Faulkner the largest when folding a 24 diopter lens. We also describe a protocol that can be used to evaluate new IOL folders.</div>
</front>
</TEI>
<pubmed><MedlineCitation Owner="NLM" Status="MEDLINE"><PMID Version="1">8064608</PMID>
<DateCreated><Year>1994</Year>
<Month>09</Month>
<Day>22</Day>
</DateCreated>
<DateCompleted><Year>1994</Year>
<Month>09</Month>
<Day>22</Day>
</DateCompleted>
<DateRevised><Year>2008</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0886-3350</ISSN>
<JournalIssue CitedMedium="Print"><Volume>20</Volume>
<Issue>3</Issue>
<PubDate><Year>1994</Year>
<Month>May</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Effect of folding instruments on silicone intraocular lenses.</ArticleTitle>
<Pagination><MedlinePgn>310-5</MedlinePgn>
</Pagination>
<Abstract><AbstractText>The Faulkner holding and folding forceps, the Fine folder, and the Prodigy inserter (PRO-1A) were evaluated to assess their effects on silicone intraocular lenses (IOLS) after the lenses were folded. The IOLs were evaluated before folding and at two and 24 hours after folding for haptic dimension, optic quality, and surface quality. None of the instruments caused a clinically important effect on the IOLs 24 hours after folding. The cross-sectional area required for IOL insertion was calculated for each folder. The Prodigy required the smallest cross-sectional area and the Faulkner the largest when folding a 24 diopter lens. We also describe a protocol that can be used to evaluate new IOL folders.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Brady</LastName>
<ForeName>D G</ForeName>
<Initials>DG</Initials>
<AffiliationInfo><Affiliation>Research and Development Department, Allergan Medical Optics, Irvine, California 92718.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Giamporcaro</LastName>
<ForeName>J E</ForeName>
<Initials>JE</Initials>
</Author>
<Author ValidYN="Y"><LastName>Steinert</LastName>
<ForeName>R F</ForeName>
<Initials>RF</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>UNITED STATES</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D012826">Silicone Elastomers</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName MajorTopicYN="N" UI="D002387">Cataract Extraction</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D007910">Lenses, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D008855">Microscopy, Electron, Scanning</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D055095">Optics and Photonics</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="Y" UI="D012826">Silicone Elastomers</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000737">chemistry</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName MajorTopicYN="N" UI="D013499">Surface Properties</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="pubmed"><Year>1994</Year>
<Month>5</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>1994</Year>
<Month>5</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>1994</Year>
<Month>5</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">8064608</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002128 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 002128 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= PubMed |étape= Curation |type= RBID |clé= pubmed:8064608 |texte= Effect of folding instruments on silicone intraocular lenses. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i -Sk "pubmed:8064608" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |